Product Description:

1.Technical Date:

Size: DN25-DN1200

Nominal Pressure: PN10/PN16

Operation Temperature: -10°C~150°C

Suitable Medium: Water,Sewage,Seawater,Gas,Food,Oils,etc.

2. Standard

Design Standard: GB/T 12238-2008

Structural Length: GB/T 12221-2005

Top Flange dimensions: ISO5211

Face to face dimensions: GB9112,DIN2501,BS4504,ISO2084,ANSI125

Type of connection: Wafer Type

3. Feature:

 This valve is mainly composed of body, butterfly plate, valve shaft, seat and transmission devices. Simple and compact structure, small portable, convenient for transport, install and dismantle. 90 degrees of opening and closing, switch quickly, operating is small, light energy; Sealing performance is good, service life is long, can achieve zero leakages. Flow curve tending to straight line, excellent regulation performance.

4. Sealability:

The valve for rubber seal, closing butterfly plate and seat sealing performance is good, two-way sealed good performance and the torque is small. the friction is very small between butterfly plate and the seat seal. The valve shaft drive the butterfly plate, butterfly plate do 90 degrees rotation. Butterfly plate flexible for opening and closing, no card acerbity, beating phenomenon, small torque.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Ok, My zone-valve is dead. How do i find/fix it?
do mean you have an area in house that the heat isnt working in? if so try by passing the thermostat zone valve is that same as circulator pump its valve in the line to radiator usually near boiler has wires onit that go to thermostat should be a circulator pump for each thermostat
Q:QUestion about Valves during cardiac cycle?
A heartbeat is a two-part pumping action that takes about a second. As blood collects in the upper chambers (the right and left atria), the heart's natural pacemaker (the SA node) sends out an electrical signal that causes the atria to contract. This contraction pushes blood through the tricuspid and mitral valves into the resting lower chambers (the right and left ventricles). This part of the two-part pumping phase (the longer of the two) is called diastole. The second part of the pumping phase begins when the ventricles are full of blood. The electrical signals from the SA node travel along a pathway of cells to the ventricles, causing them to contract. This is called systole. As the tricuspid and mitral valves shut tight to prevent a back flow of blood, the pulmonary and aortic valves are pushed open. While blood is pushed from the right ventricle into the lungs to pick up oxygen, oxygen-rich blood flows from the left ventricle to the heart and other parts of the body. After blood moves into the pulmonary artery and the aorta, the ventricles relax, and the pulmonary and aortic valves close. The lower pressure in the ventricles causes the tricuspid and mitral valves to open, and the cycle begins again. This series of contractions is repeated over and over again, increasing during times of exertion and decreasing while you are at rest. The heart normally beats about 60 to 80 times a minute when you are at rest, but this can vary. As you get older, your resting heart rate rises. Also, it is usually lower in people who are physically fit.
Q:Pulmonary Valve Stenosis?
1761 - Pulmonary valvar or valvular stenosis is one of the more common forms of congenital heart malformations and it has been extensively studied since the original description of pulmonary valve stenosis by John Baptist Morgagni in 1761. 1888 - Tetralogy of Fallot, first characterized by Dr.Etienne Fallot in 1888, is present in about 3000 children born each year in the United States. It is a combination of four heart abnormalities. Dodrill and his colleagues employed it with success for the open correction of a stenotic pulmonary valve in October 1952.
Q:What type of butterfly valves do you have in DN125?
Three eccentric PTFE sealing flange butterfly valve, three eccentric hard sealing flange butterfly valve, clip butterfly valveWorm, D343F-16C, snail, D343H-16C, manual, D71X-10, D71J-10Pneumatic D643F-16C pneumatic D643H-16C worm, D371X-10, D371J-10Electric D943F-16C electric D943H-16C pneumatic D671X-10 D671J-10Quick release valve, KTOD643F-25C quick opening valve, KTOD643H-25C electric D971X-10, D971J-10Quick closing valve, KTCD643F-25C fast closing valve, KTCD643H-25C pipe network, GD971X-10 GD971J-10Anti theft GDS971X-10 GDS971J-10Long rodWorm CD343F-16C long poleWorm CD343H-16C long poleThe cochlea is CD371X-10 CD371J-10Long rodElectric CD943F-16C long rodElectric CD943H-16C long rodElectric CD971X-10 CD971J-10Wait a minute, that's enough for your reference
Q:Butterfly valve common faults and treatment methods?
Three, summary:Only familiar with every detail of circulating water pump outlet valve and butterfly valve equipment, timely and thorough maintenance and strict debugging, to ensure the safety and reliability of equipment operation, to ensure the healthy and orderly operation of equipment.
Q:How can one - way sealed butterfly valves and two-way sealed butterfly valves be distinguished?
One way sealing butterfly valve is the front of the butterfly valve. When it closes, it must face the direction of the medium. The medium flows only in one direction, and the arrow on the valve body indicates the direction of the flow direction of the medium. Attention should be paid to the flow direction of the medium during installation. The two-way sealing butterfly valve is that the butterfly plate can face or back the direction of the medium, and the installation needs no attention to the direction of the flow of the medium, and the valve body also has no indication of the direction of the flow direction of the medium. Two way sealing butterfly valve stem force is greater than one-way butterfly valve stem. Design, the same diameter, pressure butterfly valve, two-way sealing butterfly valve stem diameter than one-way sealing butterfly valve stem diameter.
Q:What's the difference between an electric two position control valve and an electric butterfly valve?
With manual control device, once the power failure occurs, you can temporarily manually operated, and will not affect the use.The biggest difference is that the electric double bit butterfly valve can not fine adjustment; and the electric butterfly valve can play a regulating role.
Q:can't locate freon intake valve for 03 jaguar?
If it has one it should be located on the smaller line near the AC compressor.
Q:How can you tell the difference between a functional valve murmur and a non-functioning valve murmur?
mechanical okorder.com/
Q:What's the difference between the three eccentric butterfly valve and the two eccentric butterfly valve?
Single eccentric butterfly valve: extrusion problems, address concentric butterfly valve and valve seat of the resulting in a single eccentric butterfly valve, the structural characteristics of the stem axis deviated from the disc center, so that the butterfly is no longer a rotary bottom plate, axial dispersion, reduce the excessive squeezing and the lower end of the seat of the butterfly board. Double eccentric butterfly valve: in the single eccentric butterfly valve on the basis of further improvement of forming, is the most widely used double eccentric butterfly valve.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range