Voltages up to 35kv PVC/XLPE Power Cable

Ref Price:
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
200 m
Supply Capability:
20000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications

PVC/XLPE power cable up to 35kv
1.Professional supplier
2.Reliable quality,best price
3.Strong capacity,fast delivery
4.ISO

Voltages up to 35kv PVC/XLPE Power Cable

 

Brief Introduction

PVC/XLPE power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.

 

Standard

The products can be produced according to our factory specification which is equivalent to the standard IEC60502.The factory can also design and manufacture special power cable according to the other standards required by the customers.

 

Properties of  PVC Power Cable

 

1.The long-time permissible working temperature of cable conductive core is not more than 70 degrees.

 

2.During short circuit (max permanent time is not more than 5 seconds), the max temperature of cable conductor is not more than 165°C.
3.The difference level of laying cable is not restricted.When laying the cable,ambient temperature is not lower than 0°C.
4.They have good chemical stability,and properties of acid resistance,alkali resistance,salt resistance,oil resistance,solvent resistance and flame resistance.

 

Properties of XLPE Power Cable

1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.

2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.

3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.

4.Excellent electrical performance, resistance to chemical corrosion.

5.Can stand advisable traction when laid.Can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.

 

Nominal Cross-sectional Areas

1.5 mm2 , 2.5 mm,4 mm2 , 6 mm2 , 10 mm, 16 mm2 ,25 mm, 35 mm2 , 50 mm,70 mm,

95 mm,120 mm,150 mm2 ,185 mm,240 mm2 ,300 mm  400 mm2  , 500 mm2  ,   630 mm2  , 

800 mm2

 

Production range

Single core cable: from 1.5 mmto 800 mm2,

Multi-core cable: from 1.5 mm2 to 400 mm2

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to connect the power cable pre-branch connector
Pre-branch cable detection: a In addition to routine pressure test, it is necessary to increase the insulation resistance test, with a shake table can be completed in each branch after the completion of injection The table measures the insulation in the finished product After the pressure is also used to detect the insulation of the table to prevent the water cooling process in the branch of the water caused by short-circuit, the general AC voltage test can not detect, can only increase a set of table detection process B Core conduction detection, In each branch body should be tested with the trunk of the conduction test to prevent the production process due to improper operation caused by the branch and the trunk circuit
Q:Ipad charge does not enter the charge does not support this accessory charge
You ask this is too professional, it is difficult to answer, to ask the air conditioning technical staff Caixing.
Q:Power cable inspection, how many meters should be sampled?
in the wide-linked pricing software GBQ40 to achieve, directly enter the corresponding quota, click on the quota below the" standard conversion ", the cable laying five core check , You can achieve the fixed sub-sub-multiplied by the coefficient of 13 For example: YJ - cross-linked polyethylene insulation (insulation) V - PVC jacket (outer jacket) did not mark the conductor material that is the default copper wire, if the aluminum wire should be YJLV4 * 70 + 1 * 35 core (Mm ^ 2) + Neutral core (indicated by "1") × Neutral core cross section (mm ^ 2) CT - Indicates the cable tray in the laying mode
Q:Ceiling on the wire after the tube is the tube on how to fix it on the ceiling?
General telephone lines, lighting control lines or wire diameter in the 1.5 square millimeters of small lines with 4 points. More than the aforementioned line will use the 6 points.
Q:Power cable ZRYJV-4x70 + 1x35 What does it mean?
2 cable in a variety of environments in the laying of the layout, spacing should meet the design requirements
Q:What are the requirements for the spacing between the strong and weak wires?
Notebook does not have the opportunity to DIY. The reasons are as follows: Notebook motherboard non-versatile motherboard, the shape of the motherboard, positioning holes, screw holes are not uniform standards, each manufacturer's motherboards are their own engineers and then open factory production model. Notebook shell corresponding to the interface location, type and screw hole location is with a specific motherboard supporting.
Q:What is the interface between the power interface and the hard disk?
How can you pick up the computer, Internet cafes router connected to the tap, each tap has a lot of jacks, so you can pick up so many computers, you can carefully observe the Internet cafes, some iron box there are a lot of green In the flash is the tap
Q:Choose the configuration of good or bad computer graphics card memory processor, etc., how to choose a different manufacturers
Said cross-linked polyethylene insulation, double steel armor, PVC outer jacket. Voltage level 0.6 to 1 kV, 5 core, cross section 10 square millimeters. About four centimeters in diameter.
Q:The difference between power cable and overhead cable
His answer is correct! There is overhead cable generally use aluminum core conductor! Because light weight Overhead cable under normal circumstances are 6kV below the cable! If the voltage level is high, you need to do special craft production!
Q:What does the cable ZR-YJV22-4 * 16 mean?
ZR-YJV1KV6mm ^ 2 * 3 for the copper core flame retardant XLPE insulated PVC sheathed power cable, three core, nominal cross-section 6 square millimeters, rated voltage 1kV, model specifications specification: ZR-YJV1KV3X6mm ^ 2.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range