Voltages Up to 35kv pvc Power Cable

Ref Price:
Loading Port:
China main port
Payment Terms:
TT or LC
Min Order Qty:
1000 m
Supply Capability:
20000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Voltages  Up  to  35kv  pvc  Power  Cable

 

Brief Introduction

PVC/XLPE power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.

 

Properties of  PVC Power Cable

 

1.The long-time permissible working temperature of cable conductive core is not more than 70 degrees.

 

2.During short circuit (max permanent time is not more than 5 seconds), the max temperature of cable conductor is not more than 165°C.
3.The difference level of laying cable is not restricted.When laying the cable,ambient temperature is not lower than 0°C.
4.They have good chemical stability,and properties of acid resistance,alkali resistance,salt resistance,oil resistance,solvent resistance and flame resistance.

 

 

Properties of XLPE Power Cable

1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.

2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.

3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.

4.Excellent electrical performance, resistance to chemical corrosion.

5.Can stand advisable traction when laid.Can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.

 


Picture

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Lost my Acer AL1716 monitor power cable?
unerversal 3 prong power chord for pc
Q:Does the GeForce 9800 GT require it's own power cable?
everything should of came in the box, if it was connected correctly it would read the new card. once its running, you'll be satisfied.
Q:Best solution to prevent damage to laptop by tripping on the power cable?
I would suggest using the velcro tye's you can get at any electronic store. Try tying off at the leg of your table. You can also use gaffing tape to tape it down to your floor. Gaffers tape usually doesn't leave a residue and is easily removed. Again, you can get it at Home Depot int he electronics section. Oh yeah, and be careful. :o)
Q:what are the 2 cables for on a sata drive?
There's a third connector you might have noticed, which is the jumper pin settings. You don't need to play with that -- the jumper pins are there for you to set your hard drive into 1.5 GB and 3.0 GB speed modes. By default, it's set to 3.0 GB. You change it to 1.5 GB if your motherboard demands it.
Q:Electronic power supply?
Yanking a power cable out of a PC that's running, could lead to a voltage spike. This can fry your power supply, and possibly go further. (Motherboard, ram, graphics card) Same thing, with having a computer power cable plugged into a surge protector, and then plugging it into the power supply. YOU, can replace the components of a Personal Computer. It's too technical and dangerous to try it with a TV, unless you're a qualified tech, and have the required tools.
Q:How to determine whether the square of the cable is standard
Horizontal laying of the cable within the cable, generally do not need fixed, natural laying can be. Vertical laying section of the cable within the bridge, with the need to match the line card, the use of tied rope (multi-purpose single insulated wire) one by one fixed cable, fixed spacing should meet the requirements. According to the control cable and the power of the different layers of laying, if the power cable to be multi-layer need to have 300mm spacing (or load capacity is large enough), if it is control cable, casually laying, if the laying of power cable laying below Layer, above the laying of control cable, but not too much affect the power cable cooling. If the high-voltage cable and low-voltage cable in principle do not allow common laying.
Q:Wiring of car sound (without front fuse on power cable)?
Could you install it without a fuse. Yes. Should you install it without a fuse. No. If your power wire ever got shorted out it would melt and catch of fire. Their have been cars that burned to the ground because they did not have fuses.
Q:What to do if a power cable fell in my driveway?
Do not call 911, call the power company. If your city has 311 service you could call that. If there are any bodies around the line just leave them be. Don't try and move them with a broom handle, that's an old wive's tale.
Q:What is the cable for the YJV33 cable?
DDF (digitalDistributionFrame) digital patch panel DDF digital patch panel digital patch panel, also known as high-frequency patch panels, digital communications in the increasingly superior, it can make the digital communications equipment, digital data stream connection as a whole , From the rate of 2Mb / s ~ 155Mb / s signal input and output can be terminated in the DDF rack, which wiring, transfer line, transfer, expansion have brought great flexibility and convenience of double deoxidation (DideoxyFingerprints, ddF) 2
Q:Outlets loosing power after hitting lower leg with cable snake.?
Would I be right in thinking you sort of tripped on flexible metal conduit in which electric cables run and now the power is intermittent and trips the breaker? I would start by isolating the circuit so it is no longer live and checking the connections at each end of the cable run because any strain on the conduit could have tugged wires out of their terminals. I'd make sure that all the connections were tight and the wires properly anchored and also that each wire is in the correct terminal. I once made a mistake when replacing a socket outlet because the terminals in the new one were the exact opposite of the old one. Luckily, I found it straight away when I tested the circuit. If the connections all look good, I'd check the continuity along each of the cables. It is inconceivable that the cables inside the metal conduit were damaged as they should be continuous cable runs with no joins. The continuity test will tell you if any cable is no longer continuous, but I'd be very surprised as long as the original installation was done properly to code (or wiring regulations in the UK). Obviously, before you start checking the cables, you would unplug or disconnect everything that is connected to them. If the fault only happens when some sort of machine or appliance is connected, then it suggests the fault is with the appliance or machine and not the wiring. A 20 minute cycle of faults makes we wonder whether there is a fridge or a freezer connected the circuit. If so, I'd get it checked for faults and check that the power connection to it is correctly wired. I am not an electrician, just an experienced home owner, so please double check anything I've said. Good luck.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range