Product Description:




VPM SERIES
PERFORMANCE RANGE
Flow rate up to 25 l/min.(1.5m
3/h)
head up to 80m

PUMP INSTALLATION AND APPLICATIONS
Vibration pump(VMP70) is designed for clear water lifting from boreholes with a diameter over 120mm and depth up to 80 meters, water wells and any reservoirs, it can be used for water vegetable gardens, orchards, ad well as for domestic water supply.

This pump does not comprise friction surface and rotation parts, thus providing a durable and trouble-free operation.

Model

Power
(Kw)

Power
(Hp)

Outlet
(mm)

Max.Flow
(L/min)

Max.Head
(m)

Diameter
(mm)

GW
(kg)

Packing Dimension

VMP70

0.37

0.5

18

25

80

120

4.6

33*12*16

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Variable flow variable frequency water pump how to adjust the flow?
Variable frequency pump is mainly depending on the frequency converter to adjust the speed of the pump motor, thereby regulating the flow and lift pump, the following Q1/Q2=n1/n2; H1/H2= (n1/n2) -, the frequency range of the frequency converter in 30HZ~50HZ
Q:What are the categories of pumps?
First, select the pump to meet the requirements of the headThe so-called head refers to the required lift, and not lift the water height, clear this point, the choice of water pumps is particularly important. Pump lift is about 1.15 to 1.20 times the height of lifting water. If the vertical height of a water source to the water is 20 meters, the required lift is about 23~24 meters. When selecting a pump, the pump head should be close to the required head, and the general deviation is not more than 20%. In this case, the efficiency of the pump is the highest, and it is more energy efficient, and the use will be more economical. If the lift on the nameplate is much smaller than the required lift, the pump can not meet the needs of users, even if the water can be pumped, the water is also very poor. But in turn, the high lift pump for low head, there will be heavy traffic, resulting in motor overload, if long time operation, the motor temperature, the winding insulation layer will gradually aging, and even burning motor.Two, select the appropriate flow pumpWater pump flow, that is, the amount of water is generally not too large election, otherwise it will increase the cost of water pumps. Should be selected as needed, such as the use of the user's family self-priming pump, the flow should be chosen as small as possible; if users use the submersible pump irrigation, you can properly select a larger flow.
Q:How should the water pump breaker be selected?
If it is a single-phase motor, rated current is 75A; three is about 30A; the contactor should be 1.1-1.5 times the rated current of the motor protection type selection of circuit breaker, circuit breaker: RMM1-100/33002 or 50A motor comprehensive protector, the price is not expensive.The circuit breaker (English Name: circuit-breaker circuit, breaker) refers to the closing, carrying and breaking current conditions and normal circuit switch device, load and breaking current loop abnormal conditions within the stipulated time. The circuit breaker is divided into high voltage circuit breaker and low voltage circuit breaker according to its range of use. The demarcation line of high and low voltage is fuzzy. Generally, more than 3kV is called high-voltage equipment.The circuit breaker can be used to distribute electricity, not frequently start asynchronous motors, the protection of the power line and a motor, can automatically cut off the circuit when they occur serious overload or short circuit and under voltage fault combination, its function is equivalent to the fuse switch and less thermal relay etc.. Moreover, after breaking the fault current, there is no need to change the components. At present, it has been widely used.Distribution is an extremely important link in the generation, transportation and use of electricity. Distribution systems include transformers and various high and low voltage electrical equipment. Low-voltage circuit breakers are a wide range of electrical equipment.
Q:What is the function of boiler feed pump, condensate pump, vacuum pump and low drain pump in operation?
The feed water pump is the water pump for the entire boiler, and the water needed by the boiler is supplied by a feed pumpThe condensate pump is supplied to the deaerator after condensing the condensate from the turbineVacuum pump water jet pump should be said, to ensure the turbine vacuum pumpThe low drain pump is the power pump of the low temperature heater
Q:2 pumps parallel, lift the same, pump head is not stacked?
2 pumps parallel, lift the same, pump head is not stacked?;Answer: the head can not be superimposed, that is, a lift and a pump, but the pumping speed (flow) is two times a taiwan.2 pumps in series, the same flow, pump head is not stacked?.Answer: the head can be superimposed, that is, the pump head is two times as much as a pump, but the pump speed is the same as that of a pump.
Q:What is the reason that the centrifugal pump outlet pressure decreases and the operating current increases?
The outlet pressure decreases, indicating a decrease in speed. The increase of the current shows that the load has increased. Generally speaking, the resistance of rotating parts increases. Check that the bearings of the pump and motor are damaged as soon as possible. As soon as you replace it, you will be able to return to normal. If this is done for a long time, the motor is likely to burn out
Q:Why does the pump head decrease when the pump flow rate increases?
First of all, the power of the pump is determined by the motor. When the power is certain, work must be done. According to w=mgh, the flow determines mg, the head is h, you think, if the flow rate is large, is the head smaller?. This is theoretical, and at the same time, you see, the water pump characteristic curve can also see that the flow rate increases, the corresponding smaller head.
Q:30kW what is the flow rate of the pump?
Estimated traffic: Q = nP/ (9.8H), =70%*30/ (9.8H), =2.14/H (m^3/s)It is estimated that the efficiency of the water pump unit n=70%, power P to kW as a unit, the head H to m as a unit, you go to check the head H is how many meters, into the formula can be considered the flow rate is how many cubic meters per second.
Q:What is the water pump population pre rotation, what harm?
Is the entrance of water flow in the formation of complex turbulent flow, flow direction, shock, vibration, easy to damage the front entrance device, such as vane impeller, shaft sleeve, sealing element.
Q:What is called soft start of water pump?
Soft start has many methods, mainly used in high-power motor.Through soft starter, or frequency conversion start, or star triangle start to achieve.It means that it starts at a slower pace.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range