Vertical Multistage Stainless Steel 316 Centrifugal Pump

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
1000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Item specifice:

Material: Stainless Steel 316 Exporting countries: Ameircan,Japan,Australian etc Item: Vertical Multistage Stainless Steel 316 Centrifugal Pump

Product Description:

Vertical Multistage Stainless Steel 316 Centrifugal Pump

 

Company Introduce

My company has more than 40 years history, is the China general machinery pump industry association member units.My company has organized product research and development team, experienced high, intermediate technical staff.Complete production and processing, inspection, testing (pump performance test platform), and other equipment, to ensure that product quality is stable and reliable.Over the department, provincial, municipal and industry product quality supervision and inspection (smoke), only one is qualified to go through.Timely quality perfect after-sales service in place, favored by the majority of new and old customers rely on and praise.My company has successfully passed the national industrial products production license, ISO9001 quality system review replacement work.Relevant product standards (enterprise), metrology, standardization management system, etc., have been acceptance by the superior department in charge of the inspection.Related to product development, production management, sales and after-sales service, are performed according to the system management standard.

.jpg

 

Product parameters of Vertical Multistage  Centrifugal Pump

Capacity

up to 250 m3/h  

Head

up to305m

Speed 

up to 3600rpm

Power 

up to 200kw

Voltage

220V to 480V

Temperature range

Within 120 Deg C

 Working pressure

Within 40bar

Application of  Vertical Multistage  Centrifugal Pump

It can be used to convey various medium from tap water to industrial liquid at different temperature and with different flow rate and pressure.

CDL type is applicable to conveying non-corrosive liquid, While CDLF is suitable for slightly corrosive liquid. 

Water supply: Water filter and transport in Waterworks, boosting of main pipeline, boosting in high-rise buildings. 

Industrial boosting: Process flow water system, cleaning system, high-pressure washing system, fire fighting system.

Industrial liquid conveying: Cooling and air-conditioning system, boiler water supply and condensing system, machine-associated purpose, acids and alkali .

Water treatment: Ultrafiltration system, reverse osmosis system, distillation system, swimming pool, separator.

Irrigation: Farmland irrigation, spray irrigation, dripping irrigation 


Operation Condition of  Vertical Multistage  Centrifugal Pump

Thin, clean, non-flammable and non-explosive liquid containing no solid granules and fibers.

Liquid temperature:

Normal temperature type: -15~+70,

Hot water type: +70~+120

Ambient temperature: Up to +40

Altitude: Up to 1000m 

 

Electric motor of  Vertical Multistage  Centrifugal Pump
Full-enclosed air-blast two-pole standed motor 
Protection class: IP55 
Insulation class: F 
Standard voltage 

 

50Hz: 
1x220230/240V 
3x200220/346380V 
3x220240/380415V 
3x380415V 
60Hz: 
3X200230/346400V 
3x220255/380440V 
3x220227/380480V

 

Picture show of  Vertical Multistage  Centrifugal Pump

Vertical Multistage Stainless Steel 316 Centrifugal Pump



Vertical Multistage Stainless Steel 316 Centrifugal Pump


Why choose us

 High Quality
1.Exported to 58 Countries
2. More than 90% customers make payment before meeting us!
3. Reorder rate up to 80%
4. Never sell any renewed pumps
5. Focus on middle and high-end market,we never seize market by using inferior material

FAQ

1. How to get our quotation in time, pls answer following questions:
    1)What liquid do you transfer?oil ,food or corrosive chemical liquid,with solid particle or not and so on 
    2) What's the flow or capcity (m3/h, L/m)? 
    3) What's the discharge head (m, feet, Mpa, bar )
     If you do not have any request, we will do as our normal standard.
  4) Contact us by under  business card information
2.OEM: Ok 
3. MOQ: 1set
4. Package: Standard export wooden case(also according to your requirements)
5. Shipping ways: By sea, By air, By express
6. Lead time: 3-15days
7. Warranty Period: One year, except spare parts 

Trading market

Vertical Multistage Stainless Steel 316 Centrifugal Pump


Transportation

.jpg





Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What are the categories of pumps?
First, select the pump to meet the requirements of the headThe so-called head refers to the required lift, and not lift the water height, clear this point, the choice of water pumps is particularly important. Pump lift is about 1.15 to 1.20 times the height of lifting water. If the vertical height of a water source to the water is 20 meters, the required lift is about 23~24 meters. When selecting a pump, the pump head should be close to the required head, and the general deviation is not more than 20%. In this case, the efficiency of the pump is the highest, and it is more energy efficient, and the use will be more economical. If the lift on the nameplate is much smaller than the required lift, the pump can not meet the needs of users, even if the water can be pumped, the water is also very poor. But in turn, the high lift pump for low head, there will be heavy traffic, resulting in motor overload, if long time operation, the motor temperature, the winding insulation layer will gradually aging, and even burning motor.Two, select the appropriate flow pumpWater pump flow, that is, the amount of water is generally not too large election, otherwise it will increase the cost of water pumps. Should be selected as needed, such as the use of the user's family self-priming pump, the flow should be chosen as small as possible; if users use the submersible pump irrigation, you can properly select a larger flow.
Q:What does "ETA" mean in the selection of pumps?
NPSH refers to the cavitation, the pump is the technical parameters
Q:What is the function of open circulating water pump and shutdown in thermal power plant?
According to the water quality difference, the purpose is to provide the corresponding cooling water, for the system oil cooler, machine seal and other cooling. Open water directly from the circulating water pipe to use, the pump is delivered to the host, the small machine oil cooler, water quality is not very high, the circulating water drainage to the back pipe, water through the water filter filter impurities. The closed water takes the self closing water tank, which is used for removing salt water. General supply pumps, water pumps, sealing cooling water, condensate pumps, sealing water, generator, hydrogen cooler and other requirements of good water quality system, closed water self circulation, and through the cooler and open water circulating water heat exchange.
Q:Why should we pump water into a pump when the country uses a pump to pump it?
Because the leather cushion there is not completely sealed the water pump wall, there is a small gap in the contact, so that the piston up and down the air connection, air pressure is equal, can not pump water.And then add water to the gap closed, such upward pull the piston to make the piston below the space increases, but the air and can not go to fill the air pressure decreases, less than atmospheric pressure, only through inhalation of water to supplement water, which is forced by atmospheric pressure wells the water through the pipe and then rise to the pump. So it can be pumped up.
Q:Pump flow 6M3/H is an hour, how many tons of water?
Flow 6M3/H, that is, an hour can smoke 6 tons of water. But according to the power, head and flow calculated by formula, the water pump efficiency is 98%, can it be achieved?
Q:Why is the minimum liquid temperature allowed at 2 DEG C instead of 0?
It freezes at 0 degrees, and the pump runs and gets stuck.
Q:What is a variable frequency water pump? What's the difference between a variable frequency pump and an ordinary pump?
1, frequency conversion water pump is based on ordinary water pump. The so-called common pump means without any automatic control device of the pump, only the pump head and the motor and a base. The power supply is switched on (default: 220/50Hz or domestic power single-phase three-phase 380V/50Hz) run off, stop. Ordinary pumps do not refer to a particular type of pump, can be centrifugal pumps, pipe pumps, vortex pumps, multi-stage pumps and other pumps commonly used.2, the variable frequency pump, is supplemented by a one-way valve, pressure tank, inverter, constant pressure water supply controller, sensor, valve or electrical components in general based on the composition of water pump with automatic function, and automatic constant pressure frequency conversion water supply device. The input power of frequency conversion water pump can be single phase 220V/50Hz or three-phase 380V/50Hz, but the motor of frequency conversion water pump is usually three-phase. The incoming line is a single-phase 220V variable frequency water pump. The motor is a three-phase 220V motor, the input line is three-phase 380V, and the pump motor is three-phase 380V.Two, the differenceAccording to the definition above, the difference between variable frequency water pump and ordinary water pump is obvious. The main differences: first, the frequency pump has automatic function and constant pressure; ordinary water pump does not; second, variable frequency water pump is a unit, the price is much more expensive than the ordinary water pump.
Q:Pump frequent start will reduce the service life, I ask what kind of frequency is called frequent start?
Pump is the same, often start, not just reduce the service life of the pump, motor, contactor life will be shortened.
Q:The flow of the pump will be reduced, the speed will change, the power of the motor will change?
1, this pump flow reduction is not the reason for speed. Because it is not matching the motor frequency conversion, the frequency of power supply unchanged, the motor speed will not change.2, the flow of water pump down, the reason may be that the impeller due to cavitation or wear and tear smaller, second, the gap between the impeller housing change, and the impeller plug foreign bodies, and some of the suction port leak.3, it is possible that the whole system resistance increases, so that the work point of the pump left.
Q:Pump head is too high what's the impact?
Water pressure is too large, energy consumption is too high, you can choose near the flow of Yang Cheng

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range