Vertical Multistage Centrifugal Pump With High Quality

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
1000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Item specifice:

Item: Vertical Multistage Centrifugal Pump With High Quality Exporting countries: Ameircan,Japan,Australian etc Material: Stain Steel;Cast Iron

Product Description:

Vertical Multistage Centrifugal Pump With High Quality

 

Company Introduce

My company has more than 40 years history, is the China general machinery pump industry association member units.My company has organized product research and development team, experienced high, intermediate technical staff.Complete production and processing, inspection, testing (pump performance test platform), and other equipment, to ensure that product quality is stable and reliable.Over the department, provincial, municipal and industry product quality supervision and inspection (smoke), only one is qualified to go through.Timely quality perfect after-sales service in place, favored by the majority of new and old customers rely on and praise.My company has successfully passed the national industrial products production license, ISO9001 quality system review replacement work.Relevant product standards (enterprise), metrology, standardization management system, etc., have been acceptance by the superior department in charge of the inspection.Related to product development, production management, sales and after-sales service, are performed according to the system management standard.

.jpg

 

Product parameters of  Vertical Multistage Centrifugal Pump With High Quality

Capacity

up to 250 m3/h  

Head

up to305m

Speed 

up to 3600rpm

Power 

up to 200kw

Voltage

220V to 480V

Temperature range

Within 120 Deg C

 Working pressure

Within 40bar

Application of Vertical Multistage Centrifugal Pump With High Quality

It can be used to convey various medium from tap water to industrial liquid at different temperature and with different flow rate and pressure.

CDL type is applicable to conveying non-corrosive liquid, While CDLF is suitable for slightly corrosive liquid. 

Water supply: Water filter and transport in Waterworks, boosting of main pipeline, boosting in high-rise buildings. 

Industrial boosting: Process flow water system, cleaning system, high-pressure washing system, fire fighting system.

Industrial liquid conveying: Cooling and air-conditioning system, boiler water supply and condensing system, machine-associated purpose, acids and alkali .

Water treatment: Ultrafiltration system, reverse osmosis system, distillation system, swimming pool, separator.

Irrigation: Farmland irrigation, spray irrigation, dripping irrigation 


Operation Condition of  Vertical Multistage Centrifugal Pump With High Quality

Thin, clean, non-flammable and non-explosive liquid containing no solid granules and fibers.

Liquid temperature:

Normal temperature type: -15~+70,

Hot water type: +70~+120

Ambient temperature: Up to +40

Altitude: Up to 1000m 

 

Electric Motor of  Vertical Multistage Centrifugal Pump With High Quality
Full-enclosed air-blast two-pole standed motor 
Protection class: IP55 
Insulation class: F 
Standard voltage 

 

50Hz: 
1x220230/240V 
3x200220/346380V 
3x220240/380415V 
3x380415V 
60Hz: 
3X200230/346400V 
3x220255/380440V 
3x220227/380480V

 

Picture Show of  Vertical Multistage Centrifugal Pump With High Quality


Vertical Multistage Centrifugal Pump With High Quality


Vertical Multistage Centrifugal Pump With High Quality


Why Choose Us

 High Quality
1.Exported to 58 Countries
2. More than 90% customers make payment before meeting us!
3. Reorder rate up to 80%
4. Never sell any renewed pumps
5. Focus on middle and high-end market,we never seize market by using inferior material

FAQ

1. How to get our quotation in time, pls answer following questions:
    1)What liquid do you transfer?oil ,food or corrosive chemical liquid,with solid particle or not and so on 
    2) What's the flow or capcity (m3/h, L/m)? 
    3) What's the discharge head (m, feet, Mpa, bar )
     If you do not have any request, we will do as our normal standard.
  4) Contact us by under  business card information
2.OEM: Ok 
3. MOQ: 1set
4. Package: Standard export wooden case(also according to your requirements)
5. Shipping ways: By sea, By air, By express
6. Lead time: 3-15days
7. Warranty Period: One year, except spare parts 

Trading market

Vertical Multistage Centrifugal Pump With High Quality


Transportation

.jpg





Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Why can't sprinkler system and hydrant system share water pump in fire fighting system?
Code for design of sprinkler systems, GB, 50084 - 2001 (2005 Edition)The water pump 10. 2.1 systems should be set up independently, and should be a preparation or a preparation will set the standby pump ratio.10., 2.2, according to the two load power supply construction, it is appropriate to use diesel pump as a standby pump.Some of them used to be common pumps, and now the code emphasizes independence.
Q:Does the water pump pump the coolant into the engine or pump it out?
Strictly speaking, the pump is powered cooling fluid circulation, which is pumped into and out of the water pump is to rely on to complete the engine, the water tank and the pipelines are connected to form a closed loop, the engine cooling water tank, heat release, heat exchange by circulating cooling liquid, and let the power coolant flow up from the water, like the human heart as the power of the arteries and veins are provided by the contraction and relaxation of the heart of the.
Q:What is the difference between a low pressure pump and a high pressure pump?
The magnitude of the pressure at the outlet side of the pump
Q:Why is the water pump smaller than the pipe diameter?
The size is only a matter of convenience or experience, and a small number of tubes are already available. As long as you can pick it up, you can use it.The so-called thick pipe to reduce resistance is a certain relationship. But it shouldn't be your decision to choose the big one. Then why don't you choose the big three? Four or the thicker ones?! @! The resistance will be smaller!!!!
Q:Diving pump voltage
Small amount of water, it should be the lift can not meet the requirements, change the submersible pump is the best solution. With 380 volts, it is very likely to burn out the pump motor.
Q:Level 200 meters distance, elevation 30 meters, how much lift water pump?
Lift is usually used to overcome vertical height and pipe loss. Now you can determine the vertical height of 30 meters, 230 meters long pipeline losses but you lack of data not calculated. With the following conditions can be calculated: 1, flow; 2, pipe diameter; 3; pipeline material; 4, elbow number; 5, valve types and quantities.
Q:Pump adapter belongs to the system of fire pool equipment?
Does not belong to the fire pool system! Pump adapter is mainly used for fire engines through the adapter system pressure, outdoor fire hydrant fire with one hand, one hand is to provide water for the fire truck. According to the 10~15L/S calculation of each pump adapter
Q:What's the function of the engine pump?
The function of the water pump is to pressurize the coolant, and ensure that it circulates in the cooling system. Generally speaking, the water circulates continuously through the radiator, engine block and parts. Take away heat.. Ensure that the engine is not high temperature
Q:The water burst how to repair?
The general water burst positions for the pump body, pump cover, if not very serious welding can be used to trap, at which point the attention electrode material, most of the water pump are cast iron, so the welding difficulty is not small.If it has become deformed or has split into parts, replace it.
Q:25KW what is the lift of the pump?
2 floor, the following formula is not accurate, the margin of safety is too large.N=Q (L/s), *H (m), /102/ (0.6~0.85), /0.85As follows: for reference only: (pump flow * pump lift) / (367* pump efficiency) * pump motor power safety margin (constant general take 1.1-1.2) = pump power.Unit: flow M3/H, head MNow you know the power of the pump, but you do not know the efficiency of the pump and flow, so the pump head can not be calculated.Can the normal operation of pump flow velocity detection using ultrasonic detection equipment, combined with the calculation of pump diameter of the flow and shaft power testing equipment can use foreign advanced measure pump, electric motor with related input parameters to calculate the pump efficiency. Then use the formula above to calculate the pump head.The simple way is to ask the designer directly about the design parameters.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range