Vegetable Cutter Used for Hotel School Company

Ref Price:
Loading Port:
Qingdao
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 

Vegetable Cutter discription:

Multifunction vegetable cutting machine, cleaning machine for fruits and vegetables, frozen meat dicing machine, shredded meat, sliced meat machine corm shredding machine, ginger shoot silk machine, cut machine, cutting machine and ducks row

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What are the advantages and disadvantages of the pump control system and valve control system in the hydraulic system?
Large pump control valve controlled energy consumption at least 30% reason is that there are serious throttling loss of a throttle valve control system of severe fever but simple structure and low cost which is why now valve control system still occupy the main market reasons.Pump control system with complicated structure especially when serious nonlinear control unsymmetrical cylinder control effect is not ideal, but the biggest advantage is energy-saving and low fever America professor Monika points out that using the pump control system of hydraulic excavator energy efficiency compared with the valve control system can be improved by over 46% but costs are high. But in control, the three pump invented by Professor Quan LONG of China is a good solution. LZ can find the invention patent or find his paper on sage. It seems that there are three or four SCI about this pump
Q:What is the difference between centrifugal pump and rotary vane pump?
This is a classification problem.Rotary is classified by movement, vane pumps are rotary, volumetric pumps are mostly rotary, piston pumps, etc., is reciprocating.
Q:Concrete pump 125 pipe wall thickness
Currently mainly divided into gate valve, concrete pump and S valve concrete pump. Another is a pump consisting of a pump body mounted on an automobile chassis and fitted with retractable or bent cloth poles
Q:What flowmeter is installed after the pneumatic diaphragm pump?
The pressure decreases, the diaphragm moves slowly, and the flow decreases.This is not particularly accurate, because the diaphragm is not a metering pump, but the approximate flow can still be controlled.
Q:Why should the pump be closed when the centrifugal pump is started?
Therefore to close the outlet valve, the pump during starting output water, the minimum pump power, when the pump reaches the rated speed, slowly open the outlet valve, gradually increase the flow of water, the motor current is gradually increased to the rated current.
Q:What are the ways of hydraulic pumps?
There are several ways:Direct flow mode, such as external gear pump;Port plate, such as vane pump, axial piston pump, etc.;
Q:How to distinguish the flow and displacement in the hydraulic pump? What's the difference between the two?
For example, once you sprinkle water from the tank to the ground, one shot of water is 1000 milliliters, which is equivalent to displacement, once (pump turn) 1000 ml.,
Q:What is the working pressure of the hydraulic pump in the hydraulic transmission system?
The choice of pressure depends on the size of the load and the type of equipment. Consideration shall also be given to the assembly space, the economic conditions and the availability of components for the actuators.In the case of a certain load, low working pressure, is bound to increase the structure size of the actuator on some devices, the size must be limited, from the perspective of material consumption is not the economy; on the other hand, the pressure to choose too large, the pump, cylinder, valve and other components of the material, sealing and manufacturing accuracy requirements very high, must raise the cost of equipment.
Q:What is the "variable" of a variable pump?
These two don't mean the same thing? That is, the pump outlet can be changed
Q:What's the difference between non negative pressure and variable frequency water pump?
Re pressure to a given pressure pressure zone water supply, than frequency conversion water pump energy savingFrom a health perspective, a water tank variable frequency water pump, water tank and the atmosphere, easy occurrence of water pollution two, no negative pressure equipment without negative pressure tank and pump and valve fittings etc., no water tank, the whole process of water supply of water is completed in a closed system, with air contact to avoid two pollution problems water supply.From the management point of view, no negative pressure is fully automatic intelligent operation, reduce management costs, no water tank, reducing the trouble of tank cleaning. No negative pressure is the upgrading of variable frequency water pump products

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range