Product Description:

High Voltage 3KV ~11KV AC Driver Inverter  

 

General


CNBM high Voltage Variable Frequency Drives are designed to be highly reliable with high-performance, yet easy to use.It can satisfy users' need for changing the speed of fans or pumps,as well as improve the productivity.

The series are compatible with all types of three-phase medium voltage asynchronous motors.

 

Specification and advantages :

 


1. Voltage resource VFD, direct input of 3,3.3,4.16,6,606 and 10 kV,direct output of3,4.16, 6,6.6 and10 kV,no output transformer necessary. High input power factor, low harmonic current, no power factor corrective capacities and harmonic filters required.

 


2. Sinusoidal multi-level PWM output waveform, no output filter required, can be directly connected to standard induction motor,no harm to the insulation of the cable or the motor, low harmonics of the motor, reduction of vibration of the shafts or the vanes,with the maximal length of the output cable of 1000m.

3. Friendly human-machine interface.

 


4. Modular design of the power circuits simplifies maintenance routine.

 

 

5.The medium voltage circuits are linked with the controller by the optical fibers,which keep the controller safe and away from the disturbance.

 

6. The complete fault monitor circuit, accurate fault alarm and protection.

 

7. Integrated cooling blower

 

8. The control logic can be conveniently changed with the help of the integrated PLC.

 

9. Offer both field control and remote control in monitor station, providing convenient controlling options.

 

10. Support most of the industrial standard protocols (Profibus, Modbus, TCP/IP, etc.)

 

11. Compatible with industrial standard signal of 0-10V/4-20mA

 

12. Able to operate at either open loop control or closed loop control status with the integrated PID regulator.

 

Specification

 

Model

A03/050~
A03/100

A03/100~
A03/175

A03/175 ~A03/220

A03/220~A03/400

A03/220~A03/610

Capacity(kVA)

250~630

630~900

900~1150

1150~2000

2000~3125

Rated output current (A)

50~100

100~175

175~220

220~400

400~610

Motor power (kW)

200~400

400~710

710~900

900~1600

1600~2500

Input frequency

45Hz~55Hz

Rted input voltage

3000V±10%

Input power factor

0.95 (>20%load)

Efficiency

0.96 with rated load

Output frequency

0.5Hz~120Hz

Frequency resolution

0.01Hz

Overload capacity

120% 1 min, 150% immediately

Analogue input

0~10V/4~20mA

Analogue output

0~10V/4~20mA

Acceleration/deceleration time

0.1~3000s

Digital output/input

expanded according to requirement

Ambience temperature

0~40°C

Storage/transport temperature

-40~70°C

Cooling

air cooling

Ambience humidity

<90% without condensation

Altitude

<1000 m

IP class

IP20

Size(mm)(W×H×D)

3300×2480×1200
3900×2480×1200

4900×2480×1200
6000×2580×1200

6000×2580×1300

Weight (kg)

3000 ~5000

5000 ~7300

7300~9200

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Speed regulation method of three - phase asynchronous motor
1, frequency control, with the inverter, power 2, change the magnetic pole logarithm, not feasible. 3, stator series resistance, energy consumption
Q:Inverter alarm a043, how is it
Check processing: Check if the cable is disconnected. Check the tachometer to shield the ground. The shield is not only on the motor side, but also on the inverter side The cable of the pulse encoder should not be disconnected. The pulse encoder cable can not be laid together with the power loop cable. Use only the recommended pulse encoder.
Q:How can a variable speed multi - speed three - phase asynchronous motor be controlled by a frequency converter?
Although the waste, but can be used, we use the frequency band with two-speed motor when the output is connected to the fast three terminals, you can refer to the next
Q:The motor is 2 pole with the inverter frequency to 50hz why the speed is only 1500 rpm
Motor speed formula: N = 60f / p In the above formula N - the speed of the motor (r / min); 60 - per minute (s); F - power frequency (hz); P - pole pairs of motor rotating magnetic fields.
Q:Three sets of batteries (540V) DC power supply U / f inverter.
It is estimated that the battery should be string - and - series connection method, and then rectifier part of the converter (which may also be caused by the switch) is actually a series of diodes in series, positive and negative after the reverse is actually the battery is Negative shorts, resulting in burning, as to burn only one of the group of a few cells, it should be string - and - string and that group, because the parallel to bear it double voltage.
Q:What is the number of parameters of the motor frequency of the Siemens inverter?
It is best to provide the model of the inverter Oh!
Q:In the case of the inverter, why can not the normal operation after removing the gearbox? The motor is 4 pole.
If there is a load, it may be less than the torque. So it can not run.
Q:Is the motor having a variable frequency motor and a variable voltage motor?
It should be no change it is the input / output current is v frequency is its input / output frequency is M / Hz
Q:My laptop can not use the power adapter, and can only use the battery, how is it ah,
1, laptop power adapter can not be used, first check the power outlet, plug, cable has no virtual state, if you can tell the normal equipment damage. Should be repaired. 2, the laptop battery must be charged through the power adapter or directly for the computer power, the power adapter is not missing, if you have experience can turn on the power adapter to see if the fuse is broken, try to update the fuse can be restored. If the integrated circuit is damaged, only updated.
Q:First reduce the frequency of about one-third of the test, not the case, then appropriate adjustments!
And the inverter is connected to the positive and negative bk-dk electrical Han Han device,

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range