Variable Frequency Drive 6KV 400KW VFD VSD

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
100000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

High Voltage 3KV ~11KV AC Driver Inverter  

 

General


CNBM high Voltage Variable Frequency Drives are designed to be highly reliable with high-performance, yet easy to use.It can satisfy users' need for changing the speed of fans or pumps,as well as improve the productivity.

The series are compatible with all types of three-phase medium voltage asynchronous motors.

 

Specification and advantages :

 


1. Voltage resource VFD, direct input of 3,3.3,4.16,6,606 and 10 kV,direct output of3,4.16, 6,6.6 and10 kV,no output transformer necessary. High input power factor, low harmonic current, no power factor corrective capacities and harmonic filters required.

 


2. Sinusoidal multi-level PWM output waveform, no output filter required, can be directly connected to standard induction motor,no harm to the insulation of the cable or the motor, low harmonics of the motor, reduction of vibration of the shafts or the vanes,with the maximal length of the output cable of 1000m.

3. Friendly human-machine interface.

 


4. Modular design of the power circuits simplifies maintenance routine.

 

 

5.The medium voltage circuits are linked with the controller by the optical fibers,which keep the controller safe and away from the disturbance.

 

6. The complete fault monitor circuit, accurate fault alarm and protection.

 

7. Integrated cooling blower

 

8. The control logic can be conveniently changed with the help of the integrated PLC.

 

9. Offer both field control and remote control in monitor station, providing convenient controlling options.

 

10. Support most of the industrial standard protocols (Profibus, Modbus, TCP/IP, etc.)

 

11. Compatible with industrial standard signal of 0-10V/4-20mA

 

12. Able to operate at either open loop control or closed loop control status with the integrated PID regulator.

 

Specification

 

Model

A03/050~
A03/100

A03/100~
A03/175

A03/175 ~A03/220

A03/220~A03/400

A03/220~A03/610

Capacity(kVA)

250~630

630~900

900~1150

1150~2000

2000~3125

Rated output current (A)

50~100

100~175

175~220

220~400

400~610

Motor power (kW)

200~400

400~710

710~900

900~1600

1600~2500

Input frequency

45Hz~55Hz

Rted input voltage

3000V±10%

Input power factor

0.95 (>20%load)

Efficiency

0.96 with rated load

Output frequency

0.5Hz~120Hz

Frequency resolution

0.01Hz

Overload capacity

120% 1 min, 150% immediately

Analogue input

0~10V/4~20mA

Analogue output

0~10V/4~20mA

Acceleration/deceleration time

0.1~3000s

Digital output/input

expanded according to requirement

Ambience temperature

0~40°C

Storage/transport temperature

-40~70°C

Cooling

air cooling

Ambience humidity

<90% without condensation

Altitude

<1000 m

IP class

IP20

Size(mm)(W×H×D)

3300×2480×1200
3900×2480×1200

4900×2480×1200
6000×2580×1200

6000×2580×1300

Weight (kg)

3000 ~5000

5000 ~7300

7300~9200

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Delta inverter reported CE4 reasons? Casually asked how many kinds of CE under a total
Is it right? The next manual to see do not understand
Q:380V motor addition to the inverter, but also how to change its speed?
Rotary motor rotor series resistance adjustable speed. 4. Change the slip electromagnetic speed (slip motor)
Q:ABB frequency converter and the difference between domestic frequency converter
Optical microscope mainly by the eyepiece, objective lens, stage and mirror composition.
Q:What is the difference when using inverter frequency conversion ordinary motor and variable frequency inverter motor
First of all you have to understand the difference between variable frequency motor and ordinary asynchronous motor. 1, inverter motor cooling fan is not connected with the motor spindle, is independent, the fan rotation from the motor speed, to ensure that the motor cooling.
Q:Short-term short-circuit converter DC link positive and negative will damage the inverter?
This short circuit may not necessarily line, the inverter fan has three, one is no speed line, two are pulse, three are switching signal (this is very little, I only encountered several),
Q:Yasukawa inverter reported bb code that is the reason why the base blockade?
This should be the meaning of the drive block, that is, the drive signal is locked, there is no drive signal, and start a frequency change but no voltage output, you find someone to repair the circuit board can be used normally, this is generally the circuit board Problem, the module is less likely to be bad
Q:How to disassemble the notebook power adapter
HP laptop power adapter for the whole design of small sealed, you can follow the following steps to dismantle: 1, laptop power adapter for the injection molding package or with a strong adhesive glue, without any screws, so generally only with violence Cracked. However, as long as the method properly, after the dismantling of the power adapter can be restored to the original, do not carefully observe almost no traces of open.
Q:Which machines are used for the frequency converter
Frequency converter is widely used in the speed regulation of AC motor.Varameter speed control technology is an important development direction of modern power transmission technology, with the development of power electronics technology, AC frequency conversion technology from theory to practice gradually mature. Inverter not only smooth speed, large range, high efficiency, start current is small, smooth operation, and energy saving effect is obvious. Therefore, the exchange frequency control has gradually replaced the traditional traditional slip speed, variable speed control, DC speed control system, more and more widely used in metallurgy, textile, printing and dyeing, smoke machine production lines and buildings, Water supply, air conditioning and other fields.
Q:If it is 8-pole variable frequency motor, enter the motor nameplate parameters in the inverter input for the 4 pole can?
If the control accuracy is not high, then you can use the ordinary control. Since the choice of the inverter, it is best based on the motor nameplate to set parameters to ensure the stability of the motor running
Q:2 pole 0.75 kW motor can increase the speed through the inverter?
if the 4-pole motor to rise to 2-pole motor frequency, The frequency of the motor rises to about 100 Hz, which is easy to implement for the frequency converter.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range