Variable Frequency Converter 50HZ 60HZ 220v to 380v Inverter 4KW 5.5KW 7.5KW 11KW

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10 unit
Supply Capability:
100 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications

Variable speed drive 
1), Super quality, competitive price, good after-sale service 
2), universal motor speed control 
3) VFD

VFD AC frequency converter Inverter 50HZ 60HZ 220v to 380v AC motor Drive

Product Description

PI9000 series inverters are high performance open loop vector inverter for controlling asynchronous AC induction motors andpermanent magnet synchronous motors.

PI9000 Specification

 

Item

Specification

Control

Voltage and frequency levels

Single-phase 220,50/60Hz Three-phase 220V,50/60Hz

Three-phase 480V,50/60Hz 380,50/60Hz 

Three-phase 690V,50/60Hz

Allowable fluctuation

Voltage:±10% Frequency:±5%

Control system

High performance vector control inverter based on DSP

Output frequency

Vector control:0 to 300Hz V/F control:0 to 600Hz

Control method

V/F control, vector control W/O PG, vector control W/ PG

Automatic torque boost function

Realize low frequency (1Hz) and large output torque control under the V/F control mode.

Acceleration/deceleration control

Straight or S-curve mode. Four times available and time range is 0.0 to 6500.0s.

V/F curve mode

Linear,square root/m-th power,custom V/F curve

Over load capability

G type:rated current 150% - 1 minute, rated current 180% - 2 seconds

F type:rated current 120% - 1 minute, rated current 150% - 2 seconds

Maximum frequency

Vector control:0 to 300Hz V/F control:0 to 600Hz

Carrier Frequency

0.5 to 15kHZ;automatically adjust carrier frequency according to the load characteristics.

Input frequency resolution

Digital setting: 0.01Hz Analog setting: maximum frequency×0.025%

Start torque

G type: 0.5Hz/150% (vector control W/O PG) F type: 0.5Hz/100% (vector control W/O PG)

Speed range

1:100 (vector control W/O PG) 1:1000 (vector control W/ PG)

Steady-speed precision

Vector control W/O PG: ≤ ± 0.5% (rated synchronous speed)

Vector control W/ PG: ≤ ± 0.02% (rated synchronous speed)

Speed control accuracy

Vector control W/O PG≤±0.3% ( rated synchronous speed )

Torque response

≤ 40ms (vector control W/O PG)

Torque boost

Automatic torque boost; manual torque boost(0.1% to 30.0%)

DC braking

DC braking frequency: 0.0Hz to max. frequency, braking time:
0.0 to 36.0 seconds, braking current value: 0.0~100.0s

Jogging control

Jog Frequency Range: 0.00Hz to max. frequency;
Jog Ac/deceleration time: 0.0s~6500.0s

Multi-speed operation

Achieve up to 16-speed operation through the control terminal

Built-in PID

Easy to realize closed-loop control system for the process control.

Automatic voltage regulation(AVR)

Automatically maintain a constant output voltage when the voltage of electricity grid changes

Torque limit and control

"Excavator" feature - torque is automatically limited during the operation to prevent frequent
overcurrent trip;the closed-loop vector mode is used to control torque

Running method

Keyboard/terminal/communication

Communication

RS485/RS232/CANBUS/PROFIBUS

The optional completely isolated RS485/RS232/CANBUS/PROFIBUS communication module can communicate with the host computer.

Product standard

Product adopts safety standards.

IEC61800-5-1:2007

Product adopts EMC standards.

IEC61800-3:2005

Cooling method

Forced air cooling and natural air cooling

FAQ

 Why do most clients choose PI9000?

 

1,150% torque at 0.5hz;

 

2,Vector control with open-loop,closed-loop control;

 

3,Automatically identify the motor parameters,self-learning;

 

4,install PID,main spindle control for CNC lathe;

 

5, Modbus communication protocol,RS485 communication,CANlink;

 

6, Simple PLC and multistage speed;

 

7,Speed tracking function;

 

8,Carrier frequency automatic adjustment;

 

9,Pendulum frequency;

 

10,Various protection mechanisms (over current/over voltage/overload, overheating, etc), 

      to protect the inverter and motor.

 


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Can the four motors be tuned to 2900 rpm?
Can be used, there are problems you can consult Zhoukou City bearing mechanical and electrical companies, contact the online search Zhoukou City bearing mechanical and electrical companies can search to!
Q:Three sets of batteries (540V) DC power supply U / f inverter.
It is estimated that the battery should be string - and - series connection method, and then rectifier part of the converter (which may also be caused by the switch) is actually a series of diodes in series, positive and negative after the reverse is actually the battery is Negative shorts, resulting in burning, as to burn only one of the group of a few cells, it should be string - and - string and that group, because the parallel to bear it double voltage.
Q:Inverter signal line analog 4-20mA connection positive and negative can be reversed?
Analog input signal is particularly vulnerable to external interference, so the general use of twisted shield as a signal line; and wiring as short as possible, generally not more than 20 meters; if some use conditions are vulnerable to external serious interference, the analog signal Side need to add a filter capacitor or ferrite core.
Q:4 pole 380V 4-5.5KW frequency conversion motor and inverter about how much money, such as the use of electromagnetic speed motor comparison
4-5.5KW inverter made about 1300 or so, the frequency conversion motor about 3000 The same power of the electromagnetic governor + motor about 4000, the price is almost
Q:Does the teacher know the working principle of the inverter?
The AC power rectification of the grid input is changed to direct current, and then the direct current is changed from AC by the control circuit according to the user's setting. The frequency is determined by the user. The motor is operated at this frequency to reach the change frequency. the goal of.
Q:Inverter alarm a043, how is it
When a signal failure occurs, use the DTI board, if necessary, change P215. With P806 (Follow the parameter description) during operation can be converted to no encoder operation A043 is: n-actjump exceeds the allowable change speed of the speed encoder signal (P215) In addition, for the synchronous motor (P095 = 12): The motor speed is 2% higher than the inverter release time point. The inverter in the ready state can not exit. Check processing: Check if the cable is disconnected Check the tachometer to shield the ground Not only on the motor side but also on the inverter side The encoder cable does not allow disconnection Use only recommended encoders The encoder cable is not allowed to be laid with the power cable
Q:22kw.2 pole fan can use Fuji inverter?
according to the rated name of the fan brand and the inverter rated current control, select the current value match, or slightly larger The
Q:400w 6-pole motor should be equipped with much of the inverter?
0.75KW just fine, neither waste the inverter resources, but also to meet the occasional overload. And 0.75KW inverter is the standard model.
Q:How many types of CVT are classified?
Power transmission Power transmission is basically divided into three categories: One is the electromagnetic sliding type, it is in the asynchronous motor to install an electromagnetic slip clutch, by changing its excitation current to speed, which belongs to a more backward speed mode. Its features simple structure, low cost, easy operation and maintenance: sliding the largest, low efficiency, serious heat, not suitable for long-term load operation, it is generally only used for low-power transmission. The second class is a DC motor type, by changing the magnetic flux or change the armature voltage to achieve speed. It is characterized by large speed range, high precision, but the equipment is complex, high cost, maintenance difficulties, generally used for medium power range (dozens to hundreds of kilowatts), has been gradually replaced by AC motor. Three types of AC motor type, through the pole, voltage regulator and frequency control. The most practical application for the frequency control, that is, using a horn to obtain variable amplitude power supply, and then drive the motor speed. It is characterized by good speed performance, large range, high efficiency, can be automatically controlled, small size, wide applicable power range: mechanical characteristics in the slow speed section of constant torque, low efficiency and low efficiency is not smooth, Maintenance need professionals. In recent years, the inverter as an advanced, excellent speed device rapid development of the mechanical CVT had a certain impact.
Q:The Schneider inverter reports the nlp command
Current transformers are also possible, or power supplies

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range