Product Description:





Quick DetailsStandard or Nonstandard:  Standard Structure:  Gate Pressure:  Medium Pressure

Power:  Manual Material:  Casting Temperature of Media:  Medium Temperature

Media:  Water Port Size:  DN40mm-DN300 Place of Origin:  China (Mainland)

Model Number:  GF4 resilient gate valves:  resilient seat flange


Packaging & DeliveryPackaging Detail: air plastic bag inside/wooden box outside

Delivery Detail: 15-60days


SpecificationsDIN3352 F4 resilient seat flange gate valves

1.size:DN40-DN300

2.medium:water

3.standard:DIN

4.certificate:ISO9001 CE


resilient gate valves

1.size:DN40-DN300

2.medium:water

3.certificate:ISO9001 CE

4.standard:DIN


available medium:water

working temperature:≤80oC


flange dimensions:DIN2501


face to face dimensions:DIN3202F4.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What if the function of a valve retainer?
Valve Retainer
Q:Fire signal butterfly valve what role?
Signal butterfly valve should be human action monitoring alarm, once closed, that is, to the system alarmYou ask the two time, I answer two times, you give two points
Q:Why is the butterfly valve used for fire control?
1, this is a good question, it seems that this has not yet made a unified standard requirements, a bit confused2, personal understanding of fire water supply pipe, pipe shall be installed on the valve, because the valve is fully open all closed features of fire control system is usually required is fully open, easy management features are obvious.3, fire water supply system is also useful to butterfly valve, but mainly signal butterfly valve.The signal butterfly valve is generally installed in two parts: floor level, dry pipe, flow indicator front end, trunk pipe, wet alarm valve, front end.Floor level pipe installation is a function of the signal valve, when the floor spraying system needs repair, close the valve, open the end of the floor drain, emptying the water in the spray system, maintenance; two is the sprinkler system is not allowed inside water, when the butterfly is closed, will transmit a signal to the the fire alarm system, fire alarm system receives a monitoring signal (so called signal butterfly valve), fire sprinkler system that the floor is anhydrous state, fast repair.Wet alarm valve at the front of the signal butterfly valve with the main floor of the main role of the butterfly valve, first, maintenance, and two is the prompt sprinkler system, there is a signal butterfly valve closed, should be repaired as soon as possible.
Q:The difference between butterfly valve and gate valve
Its varieties and quantities are still expanding, and the development of high temperature, high pressure, large caliber, high sealing, long life, excellent regulation, as well as multi-function development of one valve. Its reliability and other performance indicators have reached a high level. Disadvantages, there is a certain resistance to the medium. Gate valves are more used in steam pipes and large diameter water supply pipelines, because of the general requirements of fluid resistance is small, the use of gate valve. Valve is hand wheel rotation, stem upward movement. Flow is not the same, the gate valve requires full open. Need a higher installation space, the valve sealing surface has a certain self sealing capacity, its spool by the media pressure closely with the valve seat sealing surface contact, to achieve tight leakage.
Q:Butterfly valve switch direction respectively?
If it is not to sound from behind, from large to small if that is in the open.
Q:What does the model D373H-16C of butterfly valve mean?
For example: Z543H-16C bevel gear flange plate valve, nominal pressure 1.6MPa, the valve body is made of carbon steel valves valve name according to the mode of transmission, connection form, structure, lining material and type name. But here in the name of the content shall be omitted: (1) the connection form: "flange" (2. Structure: a): valve "rod" and "flexible" and "rigid" and "single gate"; B: "straight" stop valve and throttle valve; C: ball "floating" and "one-stop"; D: butterfly valve "vertical plate type"; E: the diaphragm valve "roof"; F: Cock "filler" and "one-stop"; G: check the "one-stop" and "single"; H: "safety valve is not closed. (3) the valve seat sealing surface material in the material name Said. I have just engaged in the valve industry, mainly to do www.ssfmsh.com traps, but also hope that we learn from each other and make progress together
Q:What does "D341X-16Q" mean?What do D341-16Q letters and numbers mean for butterfly valves?
D - valve type code: Butterfly valve;3 - valve drive mode code: worm gear;4 - valve connection form code: flange;1 - valve structure type code: vertical plate type;X - seat sealing surface or lining material code: rubber;16 - nominal pressure value: PN1.6MPa;Q - body material code: QT400 - 15.
Q:What is an ERG valve?
EGR stands for exhaust gas recirculation. It recirculates your exhaust gases back into the combustion chamber to lower temperatures and NOx emissions. This valve commonly gets clogged with carbon due to the fact it's recirculating exhaust gases. If the diaphram is not broken or damaged and still works, frequently you can simply remove the EGR valve and have the carbon cleaned out. It's a dirty job, but can be done if you can get to the EGR valve. If you do need to purchase the part it typically runs about $175. Labor charges will depend on where it's located.
Q:Pulmonary Valve Stenosis?
1761 - Pulmonary valvar or valvular stenosis is one of the more common forms of congenital heart malformations and it has been extensively studied since the original description of pulmonary valve stenosis by John Baptist Morgagni in 1761. 1888 - Tetralogy of Fallot, first characterized by Dr.Etienne Fallot in 1888, is present in about 3000 children born each year in the United States. It is a combination of four heart abnormalities. Dodrill and his colleagues employed it with success for the open correction of a stenotic pulmonary valve in October 1952.
Q:Butterfly valve model D344H and D343 difference
In fact, almost all refers to the sealed variable eccentric butterfly valve.1, D344H-10C DN4002, D343H-10C DN400Let's talk about the similarities between the 2 Butterfly models: D stands for butterfly valves, 3 represents turbine drivers, and the middle 4 represents flanged connections,10 represents the pressure of 10 kg, C represents the butterfly valve, the material is cast steel, and DN400 stands for the caliber of the valve;To say that where there are differences between the 2 models, there is a place where there are differences, second means 4 of the first models is the new type sealing valve structure is variable eccentric, second of the second models of the 3 represents the structure of the valve is three eccentric, and three eccentric seal variable eccentric type is in fact a meaning.Sealed three eccentric butterfly valve, sealed variable eccentric butterfly valve, corresponding to the central butterfly valve and sealed single eccentric butterfly valve.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range