V Series Submersible Sewage Pump with Cutting System (V1300DF)

Ref Price:
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Basic Info.

Model NO.:V1300DF

Performance:Drainage Pump

Start Up:Electric Pump

Media:Water Pump

Application:Submersible Pump, Sewage Pump

Type:Blade Pump

Material:Stainless Steel

Power:Electric

Structure:Single-stage Pump

Theory:Centrifugal Pump

Assembly:Liquid Pumps

Industry:Garden Pump

Export Markets:Global

Additional Info.

Trademark:Yuanle or OEM

Packing:Export Standard Carton

Standard:CE, SGS

Origin:Taizhou, Zhejiang

HS Code:8413709190

Production Capacity:20000PCS/Year

Product Description

SEWAGE SUBMERSIBLE PUMP FOR GARDEN


APPLICATION

Applied to pumping such liquid which is not clean, with solid matter or frictional matter, low viscous, lcorrosive, crystallizable, chemically neutral and close to water. Such as:

1.  domestic wastewater treatment system

2.  School,hospital,community wastewater treatment system

3.  Irrigation and gardening

 


Features

 

1. 100% copper wire

2. Cold-rolled silicon steel sheet, with high-speed punching, improve the efficiency and precision

3. Double sides mechanical seal graphite&ceramic

4. Demagnetization of stainless steel nuts

5. Anti-rust treatment castings and electrophoresis

6. With a cutting device at the bottom of pump

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:On demand water pump?
RV section is probably under cars and transportation, others. On demand pumps are quite common and used in many RV's.
Q:function of regulator in water pump?
This might be explained with an example. There is a water tank being used by a community (or a dwelling) and it is supplied by a pump from a well. There is a switch in the tank that is wired to the pump motor. The switch is activated by a lever attached to a float in the tank. When the float is in the down position the pump runs, When the float is pushed up by the water the punp is turned off. The pump first operates and fills the tank and then shuts off when the tank is full. When the usage of water drops the water in the tank to a certain level, the pump turns on until it is full again. The float, the switch and the motor are the pump regulating devices. This type of regulation is called two-position, like a light switch. Other more involved types of regulation may adjust a valve in the pipeline from the pump . This changes the rate of flow while the pump continues to run. The first type of regulation can be called digital because the flow is yes or no. The second can be called analog because while it is on, the flow varies in amount. If I have not adequately answered your question, maybe someone else will.
Q:What is the purpose of providing recirculation line & balance leak off line for a boiler feed water pump?
The feed pumps for most power plants are multistage centrifugal pumps. They have a minimum flow requirement or the balancing forces of the various impellers are lost and the pump is damaged. A recirculation line permits a minimum flow to be maintained at all times. It goes back to the deaerator so the boiler feedwater is not lost. Note: many of these pumps have the recycle automated so it is only in operation at very low flow rates. The leak off from the balancing line is recycled for the same reason.
Q:Submersible water pump in aquarium?
well it depends, do you have any small fish? and how is the water cycled in the pump? it needs to be protected so that fish dnt obviously get sucked. before you add it in tho need it submerged in a bucket of water and add several teaspoons of salt; that will kill all the bacteria that may have grown on and inside the pump. leave it in there for minimum 24 hours (just to be sure).
Q:Why would a newly installed water pump leak?
Take it off again and inspect the metal around the hole it is going in. Make sure there are no gouges or major damage. Besides that have a friend do the seal. I know what I am, doing and sometimes just a different method, or a new set of hands does the trick. That is probably the problem.
Q:How large is the starting current for a 1.5 kW submersible pump?
1KW about 2 current, so the rated current is about 3A, and the starting current is usually 3-8 of the rated current, that is 9-24A.
Q:well water pump questions...thanks?
too much pressure in your pressure tank bleed some air out. reset pressure.
Q:How serious is a broken water pump on a car?
A okorder.com/
Q:im looking for a company in bellemeade nj, that manufactures LABAWCO, water pump?
Q:99' toyota camry 4 cyl. water pump?
camry requires special tools and not easily accesible. timing belt is a '' good idea for a 99

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range