UP to 35 KV XLPE Insulated Power Cable

Ref Price:
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
20000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications

UP to 35KV XLPE Insulated Power Cable 
1.conductor:copper 
2.insulation:xlpe 
3.high quality and fast delivery

UP to 35KV XLPE Insulated Power Cable

1 Information

 a, Number of cores:

1,  2,  3,   3+1,   3+2,    3+3,  4,    4+1,    4+2,   5 and so on.

b, Construction:

Conductor: Solid or stranded copper 
Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC) 
Filler: Polypropylene filament with lapped binding tape 
Binder: Binding tape 
Inner sheath: Polyvinyl chloride (PVC) 
Amour: Galvanized steel wire armored(SWA) or steel tape armored(STA) 
Sheath: Polyvinyl chloride (PVC) 

c, Nominal Section 
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800

d, Features

 XLPE  insulated power cable do not has excellent electric, mechanical properties,but also has powerful resistance against chemical corrosion,heat resistance and enviromental stress resistance. Its structure is simple. The long period operating temperature is +90 °C. It is conveninet to use and can be laid with no restriction of different level.

 

XLPE insulated steel wire armoured power cable: XLPE/PVC insulated power cable has a number of advantages over paper insulated and PVC insulated cable. XLPE cable has high electric strength, mechanical strength, high-ageing resisting, environmetal stress resisting antichemical corrossion, and it is simple construction, using convenient and higher operating of long term temperature. It can be laid with no drop restriction. 

Various of flame-retardant and non-flame retardant XLPE cable can be manufactured with three technology(peroxide, silane and irradiation crosslinking). The flame-retardant cable covers all kinds of low-smoke low-halogen low-smoke halogen free, and non-smoke nonhalogented and three classes of

A, B, C.

 2 Standard:

IEC60502,and BS6346, VDE, AS/NZS, UL,etc or as customer's request.

 3 The Rated Voltage(kv):

1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35 
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 - 26/35

 4 Application:

1)These cables are most suitable for direct burial or for installation on trays or ducts,  Where there is
a risk of mechanical damage, armoured cables should be used.

2) For laying in ground along route with large difference of level able to bear external mechanical forces.

5 Model and Name

 

China Type

Description

Application

Cu

Al

YJV

YJLV

XLPE insulation PVC sheath power cable (Cu/XLPE/PVC)

To be laid indoors, in tunnel, cable furrow or pipe, the cable couldn't bear mechanical force outside 

YJY

YJLY

XLPE insulation PE sheath power cable (Cu/XLPE/PE)

YJV22

YJLV22

 XLPE insulation, steel tape armor,  PVC sheath power cable

(Cu/XLPE/PVC/STA/PVC)

To be laid underground, the cable could bear certain mechanical force, but it couldn't bear great pulling force.

YJV23

YJLV23

XLPE insulation, steel tape armor,  PE sheath power cable

(Cu/XLPE/PVC/STA/PE)

YJV62

YJLV62

XLPE insulation,  no  magnetism steel tape armor,  PE sheath power cable

YJV32

YJLV32

XLPE insulation, thin steel-wire  armor,  PVC sheath power cable

(Cu/XLPE/PVC/SWA/PVC)

Be applicable to the well, water inside and fall in the bad soil, the cable cans bear the equal dint outside the machine with pull the dint

.

YJV72

YJLV72

XLPE insulation, have no the magnetism thick steel-wire  armor,  PVC sheath power cable

YJV42

YJLV42

XLPE insulation, thick steel-wire  armor,  PVC sheath power cable

Be applicable to the well, underwater with the bottom of sea, the cable cans bear the bigger pressure with lead to pull the dint.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Home improvement, the wire specifications generally how to choose? Lighting, sockets, air conditioning with a few square lines? Ground specifications can be lighter than the line of fire, zero line?
Dual-screen display expansion, but it is estimated that the graphics card is not too small to see the movie line also play the game at the same time ~!
Q:What does the cable (YJV-5 * 6) mean?
ZR-flame retardant Y-polyethylene J-crosslinked V-PVC sheathed YJV is copper core, YJLV is expressed as aluminum core, where L is aluminum. 22 indicates the type of armor armor, and 32. So the full name is: flame retardant copper conductor cross-linked polyethylene insulated PVC sheathed power cable 4 * 16 that there are a total of four copper wire, which each cross-sectional area of 16 square millimeters
Q:"Cable laying" cable cross-sectional area refers to the cable cross-sectional area, or refers to the copper core cross-sectional area
YJV22 indicates "copper core XLPE insulated, steel tape armored PVC sheathed power cable" 0.6 / 1KV indicates its pressure rating, 5 * 10 represents the cross-sectional area of each wire diameter Is square mm, referred to as the square, the diameter of the conversion is 4.05
Q:Cable WDZ-YJFE2 (4X185 + 1X95) what does it mean
According to the specification requirements: 8.10 cable bridge wiring 8.10.4 cable bridge horizontal laying, should be selected according to the load curve to support the best span, span should be 1.5-3m. Vertical laying, the fixed point spacing should not be 2m. Assuming that the height of the electrical shaft is 60 m and the fixed point spacing is 2 m, then the number of stents required is: (60/2) * 2 = 60 Assuming that the height of the electrical shaft is 60 m and the fixed point spacing is 1.5 m The number is: (60 / 1.5) * 2 = 80 mainly depends on your shaft height, and the bridge fixed point spacing, hope to help you, (* ^ __ ^ *)
Q:PVC pipe line 6 points and 4 points which big ah?
The bearing capacity of the square millimeter in the wire decreases with the increase of the wire diameter, for example, 1 mm square meter
Q:Power cable 5-color line, respectively, what color, what role?
YJ: XLPE insulation V: PVC sheathed 22: steel tape armor 8.7 / 15KV: rated voltage: 8.7 / 15 kV (phase voltage 8.7 = 15 / 1.. line voltage 15kV) 3 * 300: Three conductor cross-section of 300 square copper conductor Another: If YJLV is the aluminum core. Here is not marked what the material is conductor, you can default to copper conductor.
Q:The UV lamp is fitted with ozone and no ozone difference
Clean the copper wire to be welded, and dip a little solder paste or rosin before welding.
Q:Calculation method of wire and cable outer diameter
Tell the truth like a three-core cable, five-core cable calculation is more complicated you math good painting geometric map can still be considered
Q:What is the length of the wire that affects voltage and electricity
When the cable is laid on the multi-layer bracket, the cables are arranged from top to bottom, the first layer is the high voltage cable, followed by the low voltage power cable. The control cable is placed on the lower part of the power cable. At the bottom of the instrument cable, when the low voltage power cable With the instrument cable in the same layer of laying, should be added partition isolation. Computer communication coaxial cable, full length are required to shield the use of closed trunking.
Q:Wire and cable manufacturing process (to be detailed)?
Copper core per square of the safe current (continuous use) for the 2.5A, intermittent use of 4A, according to the power count 550W-880W.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range