Product Description:

TYPE D(D,DG,DY,DM,DF) pump belongs to single-suction, multi-stage centrifugal pump.
The technical parameter of type D pump:
Capacity Q:6~540m³/h
Head H:33~1056m

TYPE D(D,DG,DY,DM,DF) pump belongs to single-suction, multi-stage centrifugal pump.

The technical parameter of type D pump:

Capacity Q:6~540m³/h
Head H:33~1056m
Type D pump can be divided to:
Type D: The pumps are suitable for pumping clean water without solid particles or other liquids whose physicochemical property is similar to that of clean water with the temperature range from 0℃~80℃.

Type DM: The pumps are suitable for pumping clean water with few solid particles or other liquids whose physicochemical property is similar to that of clean water.

Type DG: The pumps are suitable for pumping clean water without solid particles or other liquids whose physicochemical property is similar to that of clean water with the temperature range from -20℃~150℃.

Type DF: The pumps are suitable for pumping corrosive liquid without solid particles with the temperature range from -20℃~150℃.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the liquid pump? What are their categories? What are their strengths and weaknesses?
The pump is constructed by connecting large diameter gas piston with small diameter hydraulic piston. The two piston area ratio produces a pressure ratio, and the maximum output pressure can be calculated by the pressure ratio. High pressure ratio produces high outlet pressure. You can set the outlet pressure through a simple gas pressure reducing valve. Pressure ratio * gas drive pressure = output pressure.
Q:What is the pumping property of concrete?
Pumping capacity means that fresh concrete can be transported by concrete pump, and concrete construction can be carried out with high efficiency. 'pumping' is a qualitative statement
Q:60 type concrete pump performance?
HBT60.13.90S performance parametersParameter name unit HBT60.13.90SMaximum theoretical concrete conveying capacity m3/h 69/43Maximum pump outlet pressure Mpa 13/7
Q:What does centrifugal pump mean horizontally?
Centrifugal pump horizontal opening meaning: pump shell and pump body along the pump blade horizontal central line is divided into the upper and lower halves, so that the maintenance of pump leaves when the pump top cover can be separated from the pump and bearing as a whole. No need to remove the pipe.
Q:What are the general water pump failure, how to repair?
(4) because of the long latent water and the corrosion of the pipe wall, the water inlet of the water inlet is constantly dropping. When the holes appear above the water, the air enters the water inlet pipe from the hole.(5) there is a crack at the bend of the inlet pipe, and there is a small gap between the inlet pipe and the water pump, which may cause the air to enter the inlet pipe.
Q:How to select the fire pump?
Modify the part: (the design of regional common fire pump should be in accordance with the requirements of the original design, building design) contains a 55m high building, and the basement is about 6m, the pump reached in the basement height about 61m (common fire pump should be based on the highest floor of other low floor area, low ring and take in this case, relief measures) 61 levels, the most unfavorable hydrant to reach 0.07MPa (maximum allowable 0.5MPa) plus loss of lift at least about 90m more appropriate, of course can be higher to take relief measures (120 too high), the basic flow of lossless (with the same time there is only one building fire) according to the maximum amount of a building fire water pump set can be, there must be a backup with a preparation, and then select the appropriate pump manufacturer specification query.(the 20 houses on 99m are only shared with a 135m pump)
Q:What do you mean by the self coupling device on the pump?
Installation of GAK self coupling device:The installation of automatic coupling submersible sewage pump is mainly the installation of coupling device and the lifting of pump. In the pump before the installation of the rings on the chain, and the pump used for lifting.Installation procedure of coupling device:The coupling frame with four bolts fixed on the pump body; the water outlet pipe is fixed on the substrate; positioning cone mounted on the pipe seat; the lower end of the guide pipe is sleeved in the positioning cone, the upper end is sheathed on the guide rod of the rubber block; the guide rod frame is fixed on the pool wall. The function of the rubber block: the axial compression degree of the rubber block is adjusted by the screw on the guide rod frame, so that the diameter of the rubber block is consistent with the inner diameter of the guide rod, and the guide rod is stable.
Q:What are the starting and stopping procedures for centrifugal pumps?
Before using the centrifugal pump, the operation instructions of the centrifugal pump shall be read carefully and the specific operation procedures shall be understood so as to make proper use of the centrifugal pump products. The first step is the operation of centrifugal pump inlet valve of centrifugal pump centrifugal pump for all open cavity filled with liquid, close the outlet valve, start the motor, the motor speed is normal, can gradually open the outlet valve, to adjust to the desired condition. Pay attention to self suction centrifugal pump starts to open the exhaust valve, outlet valve should be opened quickly in the normal operation of the motor, to prevent air inlet pipe off caused by cavitation phenomenon produces centrifugal pump, centrifugal pump vibration phenomenon leads to noise of the smoke is not on the water.
Q:Any center of the pump
Alignment methods and requirements:1, check two feeler dial gauge or flange coupling the parallelism, usually with clearance between the both ends of the side instead of difference, in the circumferential direction every 900 measure, the maximum and minimum gap gap difference (Ab) less than or equal to 0.3 mm.2, the coupling flanges outside the park up and down, left and right four position to check whether they are in the same line, C less than or equal to 0.1 mm.When looking for a positive C, it will affect (a - b), finding the right (a - b) will affect the C, to balance each other. It's easier for an unskilled comrade to find C (a - b) first, and then find a positive one. Through the adjustment of the motor at the foot of the gasket thickness (Ab) and meet the requirements of C.Check the inlet and outlet piping before alignment. Make sure the weight of the inlet and outlet pipe does not exert force or torque on the pump. When looking for, should also pay attention to eliminate the pump rotor movement, so as to avoid the end gap error. If checked after the pump is working, it should be carried out under cold condition.It is important to draw attention to the fact that the pump set of the complete set of factory is only rough looking (checked with a ruler) when it is shipped. It may cause displacement when it is transported.
Q:Excuse me, what is the water pump from the lotus root?
The utility model relates to a self coupling sewage pump, which is composed of a base, a self coupling frame, a guide rod, a guide rod, a support seat, etc., and the utility model does not need bolt connection

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range