Two Beams Active Infrared Detector with 3 LED

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Two Beams Active Infrared Detector with 3 LED


Main Features

1.LED signal strength indicator

2.All around rubber O ring IP66 waterproof grade

3.Appearance design patent,different from similar products

4.Use thread calibration,more convenient and accurate.

5.Adopt two aspheric surface lens,optical gathered, powerful,concentric.

6.Adopt unique base design,easy to install.

7.Light resistance reaches 50.00lux, built-in automatic adjustment light filtering system. avoid the influence from strong light or car light.

8.Totally-sealed rainproof, dustproof,etc integration structure design make it work in the bad environment properly.

9.Built-in Optical sight and particular conversion circuit design, easy to adjustment

10.The beams intercept data cycle is adjustable, it can help the beams to be more flexible and with stronger adaptability.

11.The receiver with LED signal indicator.( Calibration more accurate.)

12.Horizontal/vertical Optical angle is easy to adjust and calibrate.

13.Step precision fine-tuning, so that calibration is more accurate

14.Photosensitive redundant reach up to 99%.

15.Lightning prevention circuit design

16.Use C model circuit failure output


Technical Parameter

Name
Two Beams Active Infrared Detector
Model
ABT2-20
ABT2-30
ABT2--40
ABT2-60
ABT2-80
ABT2-100
Warning distance(outdoor)
20m
30m
40m
60m
80m
100m
Warning distance (indoor)
60m
90m
120m
180m
240m
300m
Maximum reach
200m
350m
450m
650m
900m
1100m
Optical source
Infrared LED
Detection way
2 beams blocked off at the same time
Response speed
50msec~700msec
Alarm output
Relay contact output:NO.NC contact rating:AC/DC30V.0.5A Max
Power voltage
DC10.5~24V
Power consumption
40mAmax
40mAmax
55mAmax
55mAmax
65mAmax
65mAmax
Operating environment
Temperature:-25℃~+55℃
Humidity:RH 95%
Tamper output
Contact output 1b DC24V.0.5A Max
Optical axis adjustment range
Vertical direction 20°(±10°)    Horizontal direction  180°(±90°)
Telescopic sight
Built-in
Additional functions
Light indicates,OK indicator lamp,Testing terminal



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Traffic police on the installation of warning lights and sirens is based on which provisions
Unfortunately, only the traffic police have the final say. The best way out for vulnerable groups is immigration, or fate.
Q:Self-made alarm
This is very simple, with a personal body sensor on the OK
Q:Manual fire alarm ring, how to turn off?
Yellow indicator light, when the fire emergency lights when the fault occurs, this indicator light, and accompanied by an acoustic signal (once per minute ring, each lasting 2 seconds -3 seconds; volume in front of 1 m in front of 65-85 dB , Only the AC power to disconnect, the troubleshooting, the sound and light signal will stop);
Q:Can the general wireless smoke alarm be networked?
Wireless smoke detector work, the test program alarm after power is on in the working state, in the working state light-emitting diode flash once every minute, when the detection of smoke, the detector issued a clear pulse sound and light alarm, and at the same time output The signal is recognized by the collector until the smoke is scattered.
Q:What is the manual alarm, and the principle of hand alarm?
Hand alarm according to style sub-portable, fixed, three kinds of lifting, are used in different places of the incident early warning alarm equipment, the size of the user to see the intensity and speed of the manual, the sound size can be adjusted at any time, Automatically turn off the sound and so on.
Q:Electric car alarm has been ringing how the matter
5. The alarm may not interfere with the interference, or your charger pulse interference is too large, you can connect a few hundred K in the phase line resistance on the line. We know that the current charger is the main type of pulse charging, charging the battery may be affected by the impact of the output is non-constant current DC, the alarm by its impact.
Q:Can combustible gas detectors be special equipment?
Should belong to the general fire detection equipment bar. The The Some family kitchen to use it, how could it be special equipment it ~ ~ ~
Q:My Fergus burglar alarm does not ring how the matter
2, the alarm line connection is not normal. (According to the instructions correct wiring)
Q:Sound and light sound device and sound and light alarm are different?
1, each fire zone security exit should be set fire alarm sound and light alarm, its location should be located in the floor walkway near the stairs exit.
Q:Final Fantasy 4 is the best equipment is what ~ other those who use the alarm with it, the maximum number of hands can take
As for the alarm, you can go to Babel tower sirens strange, you can endure with stealing, as long as you have the patience, you can get unlimited, a props can put up to 99, filled with a post Installed 99.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range