Twin Wall Pipe for Concrete Pump Pipe Thickness 4.5mm Length 2000mm

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT or LC
Min Order Qty:
50 pc
Supply Capability:
2000 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Product Description:

Product Name: Double Wall Elbow with Flange

  1. 1.        Specification

Twin wall elbow is created with research of us and need of the market. Its service life and working pressure are better than the casting. Besides, We can supply 90D, 45D, 30D, 25D, 20D, 15D, 10D. And it can be used for PM, JUNJIN, Schwing, Cifa, Sany, ect.

 

(1)   Material: Q235 (outside) + GCr15(inside)

(2)   Thickness: 3mm (outside) + 9mm (inside)

(3)   Technology: Quenching under high temperature

(4)   Characteristics: the inner rigidity to 63 HRC; the outside has so high toughness to keep the inner.

 

2.  Application

Concrete mixing and delivery.

3.  Package

Put into containers.

FAQ:

Q1: Why buy Materials & Equipment from OKorder.com?

A1: All products have its ISO certifications, adheres to the highest standards and a commitment to supply chain safety and customer satisfaction.

Q2: How do we guarantee the quality of our products?

A2: We have established an advanced quality management system which conducts strict quality tests at every step, from raw materials to the final product. At the same time, we provide extensive follow-up service assurances as required.

Q3: How soon can we receive the product after purchase?

A3: Within three days of placing an order, we will begin production. The specific shipping date is dependent upon international and government factors, but is typically 10 to 30 workdays.

Q4: If we can produce Double Wall Elbow with Flange according to customers request?

A4: Yes, we can produce Double Wall Elbow with Flange according to the difference country situations to make it suitable to the market and customers. We have very professional technical team to make the design.

Q5: How to make a quick resolution for after service?

A5: We have overseas branches all-around of world, If needed, the seller shall dispatch 2 engineers to the buyer's site for supervision of training. The buyer shall make available of necessary facilities &skilled personnel at site for training.

 

Images: 

 

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How can the concrete pump pipe be cleaned?
Slowly open the compressed air intake valve, compressed air will sponge ball and concrete extrusion, if the pipeline is equipped with stop valve, should first hit in the open position, and then open the valve
Q:What are the functions of concrete pump truck?
It is composed of pump body and conveying pipe. It is divided into piston type, extrusion type and water pressure diaphragm type according to the structure. The pump body is mounted on the automobile chassis, and then equipped with telescopic or bent cloth rods to form a pump truck
Q:In general, how much concrete will be transported per hour for the concrete pump and the pump?
The length of day pump 36-62m, the efficiency has little effect, regular work is generally 30-40 cubic / hour
Q:What kind of concrete pump truck?
At present, I know the pump mainly has the arm pump. This kind of arm work is flexible. Relatively fast speed. But the cost of maintenance and use is relatively high. Height limit. There are many requirements for the site
Q:What is the washing process of the concrete pump pipe?
Connect the reducing pipe and close the discharge door. Pour water directly into the hopper.
Q:What are the layout requirements of concrete pump for building engineering?
The setting of concrete pump should be steady and firm, with heavy vehicle running condition
Q:What are the fittings of concrete pump?
Hydraulic oil, eye plates, cutting rings (when the equipment reaches 5000 or more sides can be prepared) and so on
Q:How is the piping of the concrete pipe designed?
Vertical upward piping, the ground level pipe length shall not be less than 1/4 of the vertical pipe length, and shall not be less than 15m, or comply with the provisions of the product manual. A stop valve shall be provided at the root of the conveying pipe of the concrete pump Y - shaped pipe discharge port 3 - 6m, so as to prevent the concrete mixture from flowing back
Q:What are the causes of pipe blockage in concrete pump?
Therefore, in the JGJ/T10-95 "concrete pumping construction technical regulations," stipulated that the sand through the 0.315mm sieve shall not be less than 15%.
Q:Why would the plugging concrete pump pipe
When pumping, the operator shall observe the leftover material in the hopper at any time. The remaining material shall not be lower than the stirring shaft. If there is too little material, the air will be easily inhaled, which will lead to pipe blockage. The material in the hopper can not be piled too much, should be lower than the guard bar, so as to clean up the coarse aggregate and super large aggregate in time

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range