Three Phase 5 Core PVC Insulated Power Cable

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1000 m
Supply Capability:
1000000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications

electrical cable 
1.Voltage:From 1KV to 35KV 
2.Factory direct export 
3.OEM manufcturer 
4.ISO9001

 

We can customize various types of cable in accordance with your requirements

ELEECTRICAL CABLE

 

Electrical cable has a number of advantages over paper insulated or PVC Insulated cable, it has high electric strength, mechanical strength, high-ageing resisting, environmental stress

resisting anti-chemical corrosion, and it is simple construction, it can be laid with no drop restriction.

1. Standard: GB/T 12706.2-12706.3-200I, IEC 60502:1997 or relative international standard.

2. Voltage: 1/35kv

3. Conductor: Annealed copper

4. Insulation: XLPE

5. Sheath: PVC 

6.Application: It is suitable to be installed in duct, tray or direct burial, with rated voltage of U0/U (0.6/1KV) for transmitting electricity.

1.Cable Types,Names and Places for Use 

 

Type

Name

Places for Use

Cu Core

Al Core

YJV

YJLV

XLPE Insulated,PVC Sheathed Power Cable

Can be laid in indoor,outdoor,tunnels,cable canals,reinforced concrete pipelines and loose soil.cable should not bear outer mechanic force,but can bear a certain tractlonal force.

YJV22

YJLV22

XLPE Insulated,Steel Tape Armore and PVC Sheathed Power Cable

Laid underground.Cable can bear outer machanic force,but should not bear large tractional force.

YJV32

YJLV32

XLPE Insulated,Steel Wire Armore and PVC Sheathed Power Cable

Laid in indoor,tunnels and mines.Cable can bear outer mechanic force and fairly large tractional force.

YJV42

YJLV42

XLPE Insulated,Steel Wire Armore and PVC Sheathed Power Cable

Can be laid in vertical section,indoor,tunnels and mines.Cable can bear outer machanic force and very large tractional force.

 

FAQ

We have organized several common questions for our clients,may help you sincerely:

①How about your company?

A world class manufacturer & supplier of castings forging in carbon steel and alloy steel,is one of the large-scale professional investment casting production bases in China,consisting of both casting foundry forging and machining factory. Annually more than 8000 tons Precision casting and forging parts are exported to markets in Europe,America and Japan. OEM casting and forging service available according to customer’s requirements.

②How to guarantee the quality of the products?

We have established the international advanced quality management system,every link from raw material to final product we have strict quality test;We resolutely put an end to unqualified products flowing into the market. At the same time, we will provide necessary follow-up service assurance.

③How long can we receive the product after purchase?

In the purchase of product within three working days, We will arrange the factory delivery as soon as possible. The pecific time of receiving is related to the state and position of customers.Commonly 7 to 10 working days can be served.



 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Dell US version 7559 reset failure, can not open the machine
There is no such need at all. You only need to switch to a Gigabit router on any line (because the Gigabit router has reached your fiber home requirements, and do not need to pay expensive optical converter and fiber purchase costs). Gigabit router recommended netcoreNR285G / NR255G. If you really want to change the fiber, first of all you have to solve the machine with several loom of the fiber LAN connection problem, the two are you have to decide to buy finished fiber access, or to buy bulk fiber itself then (you can be responsible to tell you, If you are the latter, although the fiber is a few dollars a meter cheaper, but you need a fiber splicing machine welding fiber, this machine as long as the fiber is very expensive, about 1 meter will be eighty to ten hundred 3-5 million, as many as .000 + have, of course, if you can borrow and you will then pick the line), so under normal circumstances I do not recommend in their own homes get all the fiber LAN, so maintenance will be very troublesome. hope this helps.
Q:Copper core power cable laying (cable section YJV4 * 35 + 1 * 16mm2)
Theoretically possible, but only need to have a different power supply for each power interface, and the need for space to install a second chassis power supply, or through the extension of the power from the chassis outside the corresponding interface can be connected. And the two green lines of power and black need and get together. But from the reality, it is not necessary. The reason why to install two power is because the power of the power is not enough, then this time you can buy a power of some of the power, the money spent not much. The other one of the chassis put two power or unsafe, if put into the chassis should be more unsafe, so it is recommended to buy a power enough power on it.
Q:Dark line into the mud how to solve the mud
You say this situation, in the modern building concealed line building is a more common problem, cement casting before the embedded pipe due to the late construction caused damage, in general, more PVC pipe, since it is galvanized iron First, the pipe wall will not be destroyed, you can not consider the main problem is the pipe and the pipe interface is not strong, there are gaps, the market directly, bending, three links are only locked with a nut Of the method to be fixed in the cement slurry with the role of vibration rod, the liquid slurry on the seamless, the most simple and effective way is in the interface before the nozzle first marked with a layer of glass glue, with the lock after the nut, With a transparent tape wrapped around the solid, over the beam, with fine wire to tighten the wire tube and barbed together, after casting, immediately with fine steel wire through the experiment, found that the block, timely treatment. As for the junction box blockage is easier to handle, embedded in the junction box before: . in the next box position on the paint applied to the template, easy to cement after solidification, remove the template to find a box convenient. . with the wood chips to fill the box filled, transparent tape wrapped around the solid, easy to clear after the box, but also to prevent the junction box into the pulp. . is the junction box and the building of the wall or ribs with fine iron wire tie to prevent the cement casting "floating box."
Q:24-port network patch frame line who said something, there are patch panels when the line should pay attention to what?
The red and white on the set-top box and TV on the audio / video input group docking, other groups do not pick up. Unplug the cable network from the TV to dock it with the corresponding port of the set-top box. And then the foolishness of the seal of the locust Feng Wei Wei with TV switch to AV on it.
Q:Power cable, signal cable, control cable laying laying specification
PVC to the water pipe, wall thickness, high strength, pressure, diameter generally medium PVC drain, wall thin, medium strength, the key general larger PVC threading pipe, indoor use, thin wall, small diameter, outdoor can have different caliber The copy. The The Another threading tube is the name suggests is to wear wires and the like, so the compressive strength will be small
Q:Will the cable voltage tolerance, such as 450V / 750V, whether it is 450V RMS, 750 peak? Thank you!
The idea of the landlord is really creative. In fact, it is not difficult to do it, hands-on ability to do a little bit of their own power to start the line, replace the original line on the line. But must pay attention to the heat show is not summer, the temperature is too high will burn the host.
Q:What are the fire precautions for the cable?
1 to prevent the cable fire flame burning measures are: sealing, blocking, Tu, every, package, water spray and other
Q:How to calculate the wattage wattage and power of the wire?
When the socket line is below 4 square feet, if it is an ordinary residential project, apply the lighting threading quota If it is a plant, it should be combined with the Ministry of Construction, the distinction between the material and the equipment, whether the line terminal of the socket is a device or just a lamp or a small fan
Q:Power cable, ZR-YJV22-0.6 / 1kV-3x185 + PE95 and ZR-YJV22-0.6 / 1kV-3x185 + 95 both are the same cable? What does it mean?
Is 5 core, if there are other things, then use 5 or more if you have manual and automatic conversion, then it would use 8 or more, preferably 10 or 12 core can be a. Motor (English: Electricmachinery, commonly known as "motor") refers to the electromagnetic induction law according to the law of energy conversion or transmission of an electromagnetic device. In the circuit with the letter M (old standard with D) said. Its main role is to produce the drive torque, as a power source for electrical appliances or various machines. The generator is indicated by the letter G in the circuit. Its main role is the use of electrical energy into mechanical energy.
Q:[Help] brake wire can be changed to half line alignment
Brake core speed wire core with stainless steel, can greatly reduce the chance of rust. I support bare lines

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range