T8 LED Tube 1.2m 18w 1800lm Three Years Warranty CRI 80 MILKY COVER PF0.9

Ref Price:
Loading Port:
Shekou
Payment Terms:
TT OR LC
Min Order Qty:
3000 pc
Supply Capability:
100000 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Item specifice:

Color Temperature: CW/NW/WW IP Rating: IP44 Lamp Body Material: Aluminum
    Power(W): 18

Product Description:


 

 

 

LED TUBE LIGHT ANY WATTEAGE RA>70  G13 PF 0.9 AC85-265 INPUT VOLTAGE 1800LM GLASS MATERIAL AT USD3 PER PC

 

 

 

LED Tube Light are receiving global recognition for their energy saving capabilities, long service life ,easy installation and the ability to reduce carbon emissions across a host of different sectors.

 

Specifications of LED Tube  Light

Voltage:AC85-265V 50/60HZ

Glass

Watt: 9W/10W/12W/14W/18W/20W/22W/24W

PF 0.9

Beam Angle300 degree

LifeSpan :30,000 Hours

2-3 years warranty

CRI :RA>70,RA>80

CCT3000-3500K,4000-4500K,6000-6500K

 

 

 

Features of LED Tube Light

The LED Tube Light  is widely used and are  designed and manufactured to replace the traditional  grille  fixture ,CFL tubes , the superior SMD LED solution and purity Glass material makes the luminous efficacy high to 100LM/W, it is of excellently heat managed by conjoint structure which maintains the LED working temperature in a comfortable condition.

 

Excellent Heat Sink

SMD LED solutions

Superior High Quality

Eco-friendly

Energy Saving Perfect Replacement for All Lamp

Blast Free, Starter Free

 

 

 

 

Applications for LED Tube Light

Replacement CFL  for traditional lamp, such as store, supermarket, commerical builing and anywhere 

T8 LED Tube 1.2m 18w 1800lm Three Years Warranty CRI 80 MILKY COVER PF0.9

T8 LED Tube 1.2m 18w 1800lm Three Years Warranty CRI 80 MILKY COVER PF0.9

T8 LED Tube 1.2m 18w 1800lm Three Years Warranty CRI 80 MILKY COVER PF0.9

T8 LED Tube 1.2m 18w 1800lm Three Years Warranty CRI 80 MILKY COVER PF0.9



 

 

FAQ:

 

Why choose LED lighting products from CNBM?



Q: What is the Operating temperature?

A: -20 to +40 degree Celsius



Q.What is the Light efficiency ?

A: Upto 100LM/W



Q:What is the starting time of LED  Light ?

A: Instant

 

Q:What is the Power Factor of Led Tube?

A:0.5 or 0.9

 

Q:What is the CRI ?

A: we offer CRI70, CRI 80

 

Q:What is the beam Angle?

A:300°  beam angle, no dark space



Q:Any Mercury or Radiation or UV ?

A: NO 



Q: Are your product IEC satisfied ?

A: YES

 

Q: How Much Energy It Can Save ?

A:Can save power over 80%

 

 

Q: Your Product 100% Real Wattage ?

A: Yes, 100% enough 

 

 

Q:Which Kind of mount installation  you can offer ?

A: Recessed type and Surfaced mounted Type


 

Q: How Long of Warranty

 

A: Minimum  2-3  years, and upto 5 years


 

 

 


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to detect the good and bad of the fluorescent lamp
The most basic and simple method is to test tubes per head of the poles, the poles are conduction description is good didn't burn out, there was a head of the poles impassability (no resistance) is burnt out.
Q:What is the difference between the daylight lamp tube used in fishing steel and the normal lighting tube
Again, LED tube USES long life. LED can live up to 50,000 hours (without power), and the fluorescent tube (which does not contain power) can last 10,000 to 20,000 hours.
Q:What's the difference between a single input and a double-end input?
There is also a single-end output, which is designed to facilitate the output of the next lampline.
Q:How does the energy-saving lamp tube set quota
Energy-saving lamps usually refer to the light source (bulb) as a light source for energy efficiency, as for what quotas to set, and what kind of lamps the source is used for.
Q:How to choose daylight lamp? What is the light bulb specification?
Electric fluorescent starter switch role in the circuit, it consists of a neon tube and a capacitance in parallel, and the role of the capacitor to eliminate the power supply of electromagnetic interference with ballast tank formation, and increase the voltage amplitude of the start pulse. An electrode in the discharge tube with double metal, use neon bulb discharge heating, make the bimetallic strip when open and close, inductance ballast current mutation on both ends of the tube and generate high voltage pulse. When the fluorescent lamp after access circuit, electric fluorescent starter began to glow discharge between two electrodes, the bimetallic strip heat expansion and contact with the static contact extremely, so the power supply, ballast, filament and electric fluorescent starter constitute a closed loop, current filament preheating, 1-3 seconds when the heating time, electric fluorescent starter of glow discharge between two electrodes, then the bimetallic strip cooling and static contact is extremely disconnected, when two electrodes disconnect instantly, the current in the circuit suddenly disappeared, so ballast produces a high voltage pulse, and it has to do with power superposition, on both ends of the tube and, make the inert gas ionization inside the tube caused by arc discharge, in the process of normal light, ballast self-induction is still stable circuit in current role.
Q:Can the T5 light tube be free of ballast?
The lamp tube wants to start with high voltage small current, again in low electricity to run down work, the ballast is two kinds of effect. If you connect directly, you will burn the filament and not light.
Q:The difference between the Ledt5 lamp and the temperature 3000k and 2700k
3000k lamp tube luminescence is white point, 2700k lamp tube illuminant red a dot.
Q:What are the advantages and differences of the LED panel lights?
In the case of thickness, the luminescent panel lamp is generally more than the side glow, and the side glow is usually done
Q:Ordinary fluorescent lamp ballast can be replaced with led daylight lamp tube
Finally, the LED fluorescent tube is installed, and the head of the lamp that has a brand logo will be inserted into the base of the base.
Q:How does the lamp line connect
The one that used to be in the early part of the world, which requires the regenerator to cooperate with the light, is an inductance ballast, and the fluorescent tube now needs to glow without the regenerator. The ballast that doesn't need a regenerator is an electronic ballast. Ask to sell tubes of the owner, they all know and electronic ballast inductance ballasts, now basically eliminated inductance ballasts, everybody understand the electronic ballast is enough. If it is an old lamp, it will meet the inductive ballast. The lamp tube has two feet on each side, and the left and right sides are four feet

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range