T8 LED glass tube, 8W, 42leds/600mm, 750lm, SMD3528, G13,Ø26, AC180-260V,Constant current driver, White6500K, Warm white3000K,CE

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

T8 LED GLASS TUBE





1. Parameter:









 





Xuejing Series Model: 




LED FL- 8W-F3-XJ42 LED/ 600 MM




 




Input Voltage  (V):AC 180-260V




Power (W) :8W




Current (A)0.076A




Degree of  Protection (IP) :IP20




Material :SMD 3528




Max. Op. Temp.  :40℃




Ambient Temp.  :-10℃-40℃




Ambient  Humidity :35%




Power Factor :0.6




LED Luminous  Flux (lm) :750lm




Beam Angle  (degrees) :320°




Luminous  Efficacy (lm/watt) :90




Color  Rendering Index (Ra) :72




Average Life  (hours) :20000




Lamp Body  Material :Glass




Lamp Holder:G13




Size  (diameter):Ø26




Power :Built-in  Isolating Source 



Driver Model:Constant Current  Driver




Color and  Colour Temperature:White 6500K , Warm White   3000K


















Spec.A    Max(mm)B     Max(mm)B     Min(mm) C    Max(mm)Ø               (mm)
LED FL-8W-F3-XJ589.8  596.9  594.5  604.0  26








5. Key  Specifications/Special Features:

Features:

1) LED tube  integrates a LED light source into a traditional fluorescent form factor

2) Its unique design creates a perfectly uniform visual  appearance, which cannot be distinguished from traditional fluorescent tube  light

3) This product is  the ideal solution for up lamp in general lighting applications

4) The LED tube is  an affordable LED solution suitable for replacing T8 fluorescent lamps

5) The product provides a natural lighting effect for use in  general lighting applications, as well as instant energy-saving, an  eco-friendly solution

6) Designed to replace fluorescent T8 tubes, the LED T8 offers  an incredible lighting performance that reduces both electricity and  maintenance costs

7) With the long lamp lifespan and wide range of operating  temperature, it is ideal for applications such as offices, warehouses, car  parking, factories and kitchens








6.  Benefits:

1) Direct  replacement retrofit for fluorescent T8 tubes at much low-energy consumption

2) For retrofit on conventional magnetic ballast circuits by  simply exchanging the starter in the installation with the dummy start  supplied with the tube

3) Excellent  heat-dissipation

4) No buzzing  noise, fluorescent flickering and RF interference

5) Eliminates dark  regions at both end of the T8 tube

6) High-lumen  maintenance















7. Installation Instruction


















 






















































































































































































8.  INSTALLATION DIRECTIONS:




1. Before installation, please read instruction carefully and  preserve it well.
2. Only maintained and installed by qualified electrician.
3. Before installation, please cut off the main power.
4. Do not connect the lamp to main supply until installation is  completed.
5. Please DON’T USE LED TUBES with BALLASTS and STARTERS.
6. Please follow the Connection Schema for correct connection.  Make sure the appliance has been mounted safely.







9. CAUTION:      
1. Turn off the switch when replacing and cleaning.
2. Wipe lamp with a dry duster.
3. Do not use any chemical duster or solvent such as oil or  thinner.
4. Do not spray insecticide on this lamp.



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the minimum starting voltage for the fluorescent tube?
The fluorescent lamp is under the influence of the ballast, the voltage is 810 volts. 810 volts is transient and can only be observed with a digital oscilloscope. I measured the data in three different meters, and the data doesn't really have the same data.
Q:The Led is good, or the t5 lamp is good
Obviously use lamp to bring good! The LED T5 is designed to replace the old T5. The general sitting room USES the lamp belt to be in directly put the lamp slot, the lamp strip whole is put in go to go to the one paragraph that does not have T5 the kind of the light of a paragraph of a paragraph is not even feeling.
Q:What is the weight of an LED fluorescent tube
If it's about the weight, it doesn't go beyond 500 grams
Q:What's the difference between an LED fluorescent lamp and an ordinary light tube?
The next part of LED color temperature: the work of various lighting fixtures... | returns the advantage of the log list LED fluorescent lamp to share the copy address log address: use Ctrl + C to copy and post it to the friend. Broadcast to weibo pig eight quit to do the monk May 17, 2011, when reading and classification (0), (4) comments: personal diary permissions: public font: set-top permissions set in small cuhk more ▼ ▼ in recommended log To illicit close log Remove the edit the led fluorescent lamp to become one of the earliest to enter indoor led lamps and lanterns, because it is relative to fluorescent lamp has 10 major advantages: 1. High luminous efficiency Fluorescent lamp luminous efficiency is about 55-80 lm/W (Philips company T8 fluorescent lamp luminous efficiency is 72 lm/W), and LED the luminous efficiency of above 100 lm/W, recently Cree company XLampXP - G luminous efficiency has been to 130 lumens/W, and will improve in the future. The difference is now nearly double. And it could be more than three times that. The efficiency of lamps and lanterns efficiency is mainly to point to effective light effect, because fluorescent lamp is 360-degree, and the light that is sent in the opposite direction has no use. So fluorescent lamp USES a white chimney normally, can take a considerable part of the reverse light reflected, in general, fluorescent lamps and lanterns of efficiency is about 70%. LED fluorescent lights are 120 degrees, so all light is efficient.
Q:Is the normal daylight tube replaced by an LED line
I just changed it. I'm buying the brand's LEDT8 light bulb 1 meter 2. 16 watts is basically equivalent to the ordinary energy-saving fluorescent tube 60 watts. It's very bright and bright, and you don't need a flash. But some brands don't have to take down the ballast. The ballast and the regenerator are broken down, and the different brands are different.
Q:Put on LED lamp tube, can connect change 3 lamp tube not bright?
The problem should be: 1, your lamp holder is not in position; 2, the connection of the lamp holder is loose or the wire is broken. No short circuit at both ends of the rectifier. No short circuit in place on both ends of the rectifier, easily between the open flashing voltage is too high, if the LED lamp circuit withstand voltage protection, easy to damage, so suggest tear down ballast, connect the line again.
Q:Does the home led tube have ultraviolet light
But when buying led lights, it should be noted that the power of a single led is uneven with leds below 0.5w, and there is a basic problem in the market
Q:Why don't leds and light bulbs adjust brightness by dimming switches
A flash is a period of time and a period of time. In a second, the human eye is not able to see more than 60 times, and can see the frequency of the flash, indicating that the fluorescent lamp is not always bright, but has the time of extinction.
Q:What happens when daylight lights go on
Fluorescent lamp is made of daylight lamp, ballast, consisting of the starter, under normal circumstances fluorescent lamp in the process of start, due to the action of bimetallic strip within the starter, make a sound, "da" start fluorescent work light. The sound is usually the "buzz..." when it's on. Current sound, the sound is due to the ballast assembly is not tight, leaching asphalt technology is bad internal noise caused by loose of silicon steel sheet, and some small factory's products to reduce costs is omitted asphalt link, appear easily in the use of sound.
Q:Fluorescent lamp double lamp tube wiring method
Is ok, if the electronic ballast, take a look at is a of the area, or area of two, if is one of the region, the four lines of the same light foot directly connected to the ballast end (the end of the four terminal) ballast directly connect the power cord is ok, on the other side of the ballast area 2, the light of the light feet a line connected to the ballast, on the other side of the ballast connect the power cord is ok!!

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range