• T8 LED glass tube, 12W, 68leds/900mm, 1300lm, SMD3528,G13,Ø26, AC180-260V,Constant current driver, White6500K,Warm white3000K,CE System 1
  • T8 LED glass tube, 12W, 68leds/900mm, 1300lm, SMD3528,G13,Ø26, AC180-260V,Constant current driver, White6500K,Warm white3000K,CE System 2
  • T8 LED glass tube, 12W, 68leds/900mm, 1300lm, SMD3528,G13,Ø26, AC180-260V,Constant current driver, White6500K,Warm white3000K,CE System 3
T8 LED glass tube, 12W, 68leds/900mm, 1300lm, SMD3528,G13,Ø26, AC180-260V,Constant current driver, White6500K,Warm white3000K,CE

T8 LED glass tube, 12W, 68leds/900mm, 1300lm, SMD3528,G13,Ø26, AC180-260V,Constant current driver, White6500K,Warm white3000K,CE

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
T8 LED GLASS TUBE





1. Parameter:









 





Tianjin Series Model: 




LED FL-12W-F3-TJ68 LED/900 MM




 




Input Voltage  (V):AC 180-260V




Power (W) :12W




Current (A)0.11A




Degree of  Protection (IP) :IP20




Material :SMD 3528




Max. Op. Temp.  :40℃




Ambient Temp.  :-10℃-40℃




Ambient  Humidity :35%




Power Factor :0.6




LED Luminous  Flux (lm) :1300lm




Beam Angle  (degrees) :320°




Luminous  Efficacy (lm/watt) :105




Color  Rendering Index (Ra) :72




Average Life  (hours) :20000




Lamp Body  Material :Glass




Lamp Holder:G13




Size  (diameter):Ø26




Power :Built-in  Isolating Source 



Driver Model:Constant Current  Driver




Color and  Colour Temperature:White 6500K , Warm White   3000K


















Spec.A    Max(mm)B     Max(mm)B     Min(mm) C    Max(mm)Ø               (mm)
LED FL-12W-F3-TJ894.6901.7  899.3  908.8  26








5. Key  Specifications/Special Features:

Features:

1) LED tube  integrates a LED light source into a traditional fluorescent form factor

2) Its unique design creates a perfectly uniform visual  appearance, which cannot be distinguished from traditional fluorescent tube  light

3) This product is  the ideal solution for up lamp in general lighting applications

4) The LED tube is  an affordable LED solution suitable for replacing T8 fluorescent lamps

5) The product provides a natural lighting effect for use in  general lighting applications, as well as instant energy-saving, an  eco-friendly solution

6) Designed to replace fluorescent T8 tubes, the LED T8 offers  an incredible lighting performance that reduces both electricity and  maintenance costs

7) With the long lamp lifespan and wide range of operating  temperature, it is ideal for applications such as offices, warehouses, car  parking, factories and kitchens








6.  Benefits:

1) Direct  replacement retrofit for fluorescent T8 tubes at much low-energy consumption

2) For retrofit on conventional magnetic ballast circuits by  simply exchanging the starter in the installation with the dummy start  supplied with the tube

3) Excellent  heat-dissipation

4) No buzzing  noise, fluorescent flickering and RF interference

5) Eliminates dark  regions at both end of the T8 tube

6) High-lumen  maintenance















7. Installation Instruction


















 






















































































































































































8.  INSTALLATION DIRECTIONS:




1. Before installation, please read instruction carefully and  preserve it well.
2. Only maintained and installed by qualified electrician.
3. Before installation, please cut off the main power.
4. Do not connect the lamp to main supply until installation is  completed.
5. Please DON’T USE LED TUBES with BALLASTS and STARTERS.
6. Please follow the Connection Schema for correct connection.  Make sure the appliance has been mounted safely.







9. CAUTION:      
1. Turn off the switch when replacing and cleaning.
2. Wipe lamp with a dry duster.
3. Do not use any chemical duster or solvent such as oil or  thinner.
4. Do not spray insecticide on this lamp.



Q:How to choose daylight lamp? What is the light bulb specification?
Electric fluorescent starter switch role in the circuit, it consists of a neon tube and a capacitance in parallel, and the role of the capacitor to eliminate the power supply of electromagnetic interference with ballast tank formation, and increase the voltage amplitude of the start pulse. An electrode in the discharge tube with double metal, use neon bulb discharge heating, make the bimetallic strip when open and close, inductance ballast current mutation on both ends of the tube and generate high voltage pulse. When the fluorescent lamp after access circuit, electric fluorescent starter began to glow discharge between two electrodes, the bimetallic strip heat expansion and contact with the static contact extremely, so the power supply, ballast, filament and electric fluorescent starter constitute a closed loop, current filament preheating, 1-3 seconds when the heating time, electric fluorescent starter of glow discharge between two electrodes, then the bimetallic strip cooling and static contact is extremely disconnected, when two electrodes disconnect instantly, the current in the circuit suddenly disappeared, so ballast produces a high voltage pulse, and it has to do with power superposition, on both ends of the tube and, make the inert gas ionization inside the tube caused by arc discharge, in the process of normal light, ballast self-induction is still stable circuit in current role.
Q:Fluorescent fluorescent lamp tube can replace led fluorescent lamp tube?
The original circuit was an alternating current that was attached to the ballast, and the ballast two to the two sides of the fluorescent lamp; To install led fluorescent lights, remove the ballast directly, and the positive and negative poles of the exchange are connected to the two sides of the led fluorescent lamp.
Q:What happens when daylight lights go on
It will be nice in a few minutes, maybe a bad fluorescent lamp, and now it's all LED
Q:How do fluorescent tubes clean
Use damp and wet towel to wipe to be able, pay attention to want to turn off the power, lest electric shock!
Q:The notice of LED daylight lamp tube
The service life of the LED fluorescent tube, LED fluorescent lamp power saving more than 80%, life expectancy of more than 10 times of ordinary lamp, is almost free maintenance, often there is no want to change the lamp, ballast, the problem of electric fluorescent starter, about half a year down can switch back to the cost of cost savings. Green environmental protection of semiconductor lighting, the light is downy, spectrum pure, is good for eyesight protection of workers and healthy body, the 6000 k cold light source, give a person the feeling of cool and refreshing on the vision, help to concentrate, improve efficiency.
Q:What about the normal daylight tubes replaced with LED tubes, ballast and flashers?
The rectifier usually has two types of inductance and electronic type: the direct short answer of inductance (one to one). The wire and the zero line of the electronic type (two in four) are short connected to the corresponding two sets of two lines, the regenerator is pulled directly, and the LED tube is installed.
Q:Does the LED lamp need to be a national compulsory certification
Some of them need to be CCC, but most of them don't need to be CQC. This is the latest national standard. The last time I went to a certification company to listen to the lectures
Q:The various specifications of LED fluorescent tubes
LED daylight lamp tube routine parameters: 1, fluorescent lamp specifications: T8, T5, T4 difference and length of tubes, power description: commonly used with T8 and T5 fluorescent lamp specification, T4 lamp, with three tubes of a set of usually is T5 tube, commonly used fluorescent lamp specifications have T10, T12 long ago. "T", represents the "Tube", said the Tube, the Numbers behind the T Tube diameter, T8 is eight "T", a "T" is 1/8 of an inch, one inch is equal to 25.4 mm, then each of the "T" is 25.4 present 8 = 3.175 mm
Q:How much energy does normal lamp tube compare with LED light tube?
When installed the LED fluorescent lamp is very simple, the original of the fluorescent lamp to remove the LED fluorescent lamp, ballast and electric fluorescent starter, let 220 v ac mains on both ends of the LED fluorescent lamp directly. LED fluorescent lights are up to 80 percent of the electricity, and more than 10 times that of a normal lamp.
Q:The output of the led lamp is low
This should be unsegregated, and the output should be around 75v.He is unsegregated, and the output voltage is high if there is no load.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products