T8 LED GLASS TUBE





1. Parameter:









 





Yubai Series Model: 




LED FL-12W-F3-YB60 LED/900 MM




 




Input Voltage  (V):AC 180-260V




Power (W) :12W




Current (A)0.11A




Degree of  Protection (IP) :IP20




Material :SMD 3528




Max. Op. Temp.  :40℃




Ambient Temp.  :-10℃-40℃




Ambient  Humidity :35%




Power Factor :0.6




LED Luminous  Flux (lm) :1200lm




Beam Angle  (degrees) :320°




Luminous  Efficacy (lm/watt) :100




Color  Rendering Index (Ra) :72




Average Life  (hours) :20000




Lamp Body  Material :Glass




Lamp Holder:G13




Size  (diameter):Ø26




Power :Built-in  Isolating Source 



Driver Model:Constant Current  Driver




Color and  Colour Temperature:White 6500K , Warm White   3000K


















Spec.A    Max(mm)B     Max(mm)B     Min(mm) C    Max(mm)Ø               (mm)
LED FL-12W-F3-YB894.6901.7  899.3  908.8  26








5. Key  Specifications/Special Features:

Features:

1) LED tube  integrates a LED light source into a traditional fluorescent form factor

2) Its unique design creates a perfectly uniform visual  appearance, which cannot be distinguished from traditional fluorescent tube  light

3) This product is  the ideal solution for up lamp in general lighting applications

4) The LED tube is  an affordable LED solution suitable for replacing T8 fluorescent lamps

5) The product provides a natural lighting effect for use in  general lighting applications, as well as instant energy-saving, an  eco-friendly solution

6) Designed to replace fluorescent T8 tubes, the LED T8 offers  an incredible lighting performance that reduces both electricity and  maintenance costs

7) With the long lamp lifespan and wide range of operating  temperature, it is ideal for applications such as offices, warehouses, car  parking, factories and kitchens








6.  Benefits:

1) Direct  replacement retrofit for fluorescent T8 tubes at much low-energy consumption

2) For retrofit on conventional magnetic ballast circuits by  simply exchanging the starter in the installation with the dummy start  supplied with the tube

3) Excellent  heat-dissipation

4) No buzzing  noise, fluorescent flickering and RF interference

5) Eliminates dark  regions at both end of the T8 tube

6) High-lumen  maintenance















7. Installation Instruction


















 






















































































































































































8.  INSTALLATION DIRECTIONS:




1. Before installation, please read instruction carefully and  preserve it well.
2. Only maintained and installed by qualified electrician.
3. Before installation, please cut off the main power.
4. Do not connect the lamp to main supply until installation is  completed.
5. Please DON’T USE LED TUBES with BALLASTS and STARTERS.
6. Please follow the Connection Schema for correct connection.  Make sure the appliance has been mounted safely.







9. CAUTION:      
1. Turn off the switch when replacing and cleaning.
2. Wipe lamp with a dry duster.
3. Do not use any chemical duster or solvent such as oil or  thinner.
4. Do not spray insecticide on this lamp.



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to detect the good and bad of the fluorescent lamp
Normally, the filament on both ends is not broken is good.
Q:Feasibility analysis report of LED lamps
A: hello, may I help you? Is the report for the government? I have contact information in my profile
Q:What material is LED fluorescent lamp fittings, such as shell, block?
Shell is commonly aluminum and plastic, aluminium is made LED lamp cooling body aluminum profile, molding is a PC or PMMA material, high transparency requirement light effect is good, ACTS as a chimney - the light part of the leds. Plug, there are all kinds of resin, plastic (white PC/PP), metal stamping (aluminum), the role of is sealed on both ends of the tubes, at the same time support the light foot.
Q:I've just come to this company and I'm an LED fluorescent company
A lot of business today is telemarketing. 30 call a day is normal, this is to exercise their own, do not be afraid of failure, don't be afraid of rejection, specifically how to say, you can please teach you first job-seekers, observe how old colleague telephone communication
Q:How does the traditional daylight lamp tube replace the LED light tube?
The regenerator will be removed with the rectifier.I hope my answer is useful to you.
Q:An electric power saving device installed on an old-fashioned daylight lamp tube
Make a voice-controlled circuit to control the power switch.I hope my answer will help you.
Q:What is the idea of an LED daylight lamp called T5 or T8?
The so-called integration of T5 and T8 tubes, we can understand from the literal Angle, explained the T5 / T8 I won't do, you should know. Let's look at the integration The so-called integration is lamp and stents are conjoined. From what we often see T5 and T8 are generally and stent can separate the tubes, can say down from the scaffold tubes, and the integration of can't get down. I want to say so, you should be clear!
Q:How does barton fluorescent lamp holder replace led lamp tube
LED lamp installation has a variety of methods, one of the most common is the old bracket of rectifier and remove the starter, then put in two wires direct access to the ends of the lamp holder.
Q:How to replace old lamp tubes with LED tubes
The leds that appear on the market today should be connected directly to the 220V power supply. Control the power supply inside the lamp. LED fluorescent lamp, does not need a ballast, regenerator. Replacement methods: The starter of the traditional fluorescent lamp directly to the holder, to all the ballast output input line cut off, and then in the 200 v 2 wire, a root to the fixed base, a fixed socket to the other side, and just cut it off and pick up good, insulating tape, and then install the LED fluorescent lamp. The town can't go down, but now he's no longer working and he doesn't consume electricity.
Q:A 30-watt light bulb can be used for a change of LED lamp
Of course you don't rule out that the lamp you bought is bad. I hope I can help you.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range