Submersible waste water pump Ama-Porter F, S

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
1 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Design 
Vertical, single-stage, fully floodable submersible waste water pump in close-coupled design, made of grey cast iron, non-explosionproof. 
Applications 
Handling of all types of waste water, especially waste water containing long fibres and solid substances, fluids containing gas/air; removing waste water from flooded rooms or surfaces. 

Overview of technical data

Type of impellerFree flow impeller; Cutter
Maximum drive rating1, 50 kW
Impeller material (EN standard)JL1030
Type of bearingBall bearings
Drive frequency50 Hz
Maximum speed of rotation2. 900 1/min
Maximum flow rate40 m³/h
Suitable for drinking waterYes
Casing material (EN standard)JL1030
No. of impeller entriesSingle entry
Casing materialCast iron
Suction characteristicsNon- priming
Drive voltageLow voltage
eClass assignment36410101; 36410000;36410100
Pump set locationWet well
Explosion protectionOHNE
Max. permissible fluid temperature40 ******
UNSPSC classification4015150300
Free passage60 mm
Main applicationsWater; Waste water / sewage;Building services
Type of installationTransportable; Stationary
Type of casingAnnular casing
Type of connectionFlange
Type of lubricationOil / Product lubrication
Type of driveElectric motor
Installation positionVertical
Shaft material (EN standard)1. 4021
Type of couplingNone
Shaft seal typeMechanical seal; Shaft seal ring
DriveElectric motor
Maximum head16, 00 m
Minimum head1, 30 m
CutterYes
Connection to power supply400 V, 3~; 230 V, 1~

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Harm of air pump and pump
Minimum starting current when centrifugal pump of such a small impact on the grid but long closed operation will make the liquid in the pump to the pump overheating temperature is too high will lead to the problem of the seal to a certain temperature will cause deterioration of oil bearing bearing caused by excessive wear and even bite dead
Q:Variable flow pumps are variable pumps
Variable input speed, the pump out of the flow is variable, it can not be said that it is variable pump.In a word。 A variable pump is a variable displacement pump.
Q:What is the series of pumps? What's the difference between a unipolar and a multistage?
Each impeller is of the first stage. (two impellers share only one level, and exit is only level one)
Q:Does vacuum pump oil belong to dangerous goods?
Is the grease inside? How could it be dangerous goods? Absolutely not!
Q:Common failure treatment of piston pump
x09x09 (3) no connecting key on pump shaft or motor shaft1) break2) missing x091) replace key2) patch keyx09x09 (4) pump internal slide vice stuck1) the clearance is too small2) parts accuracy is poor, assembly quality is poor, gear and shaft coaxial deviation is too large; plunger head clamping; blade perpendicularity difference; rotor pendulum difference is too big, rotor slot has wound or blade has scar, force after fracture and stuck
Q:Fire hydrant pump button, under what circumstances do not need to install?
The installation of hydrant pump buttons depends on the type of water supply:(1) municipal water supply; (in this case, do not have to install)(2) there is a fire pump; (must be installed)
Q:Why is the sewage pump device coupler?
Advantages of installation and arrangement of sewage pump coupling:1. automatic coupling device, easy installation and maintenance. In the absence of automatic coupling device under the condition of fixed installation, such as pump fault maintenance personnel need to unscrew the screw pump lifting water, repair, or other small pump to pump the water down perfect maintenance, if the water is dirty, it would be difficult for people to go to the next, then the overhaul had great difficulty.
Q:Fire control center manual start fire pump directly, multi line control
The vertical line NHKVV-7*1.5 is the remote starting line of fire controller to fire pump room.
Q:What is the "variable" of a variable pump?
There are many ways to change the variable pump flow: by changing the eccentricity to change the piston stroke length (radial piston pump, the frequency change principle) motor speed to adjust the flow (such as gear pump flow control principle).
Q:How to adjust the flow of piston pump?
For the swashplate valve controlled by the solenoid valve, the swashplate is in an angle with the cylinder body, so the plunger is reciprocating in the pump cylinder when the cylinder rotates. It goes from 0 degrees to 180 degrees, that is, to the upper plunger position, the plunger cylinder volume gradually increased

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range