Submersible Sewage Pump for Sewage Water

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

                Centrifugal Submersible Pump for Sewage Water

1.Structure of WQ Series Centrifugal Submersible Pump Description

 

WQ Series Centrifugal Submersible Pump of sewage basic dormant,along with sewage pumping,sewage things gradually deposition in the bottom of the pool. But the sediment could not force with sewage went out at the pumps normal operation of inlet water alone.So the deposit is more and more at bottom of pool,which eventually led to affect normal work of pump.Engineering clean the sewage pool regularly ,so as to avoid waste of human and material resources.We produce this kind of sewagepumps,which is mounted mixing impeller at the the bottom of pumps,along with the rotation of pump, driving the impeller highspeed mixing.Thus, stir up the deposit  of bottom, mix with water, and flow out with water.Also can match with coupler,make more quick and convenient installation and maintenance.

 

2.Main Features of the WQ Series Centrifugal Submersible Pump

• Compact structure, good appearance, low construction

Operation stably, same inlet and outlet

•Convenient installation and maintenance

•Parallel connection and have many models to be chosen for difference flow rate and head

•Horizontally and vertically installation as different pipeline system

3.WQ Series Centrifugal Submersible Pump images

Submersible Sewage Pump for Sewage Water

4.WQ Series Centrifugal Submersible Pump Specification

 

ModelCapacityHeadSpeedEfficiencyPowerOutlet
Q(m3/h)H (m)n(rpm)η (%)Kwmm
40WQ-12-15-1.51215290048%1.540
50WQ-10-10-0.751010290054%0.7550
50WQ-15-15-1.51515290051%1.550
50WQ-15-20-2.21520290051%2.250
50WQ-17-25-31725290053%350
50WQ-20-7-0.75207290062%0.7550
50WQ-22-20-42220290069%450
50WQ-25-10-1.52510290067%1.550
50WQ-25-32-5.52532290049%5.550
50WQ-40-15-44015290076%450
50WQ-40-30-7.54030290062%7.550
65WQ-25-15-2.22515290052%2.265
65WQ-25-28-42528290058%465
65WQ-37-13-33713290060%365
80WQ-29-9-2.2299290048%2.280
80WQ-40-7-2.2407290050%2.280
80WQ-40-15-44015290057%480
80WQ-43-13-34313290065%380
80WQ-50-10-35010290072%380
80WQ-50-25-7.55025290056%7.580
100WQ-50-22-7.55022145063%7.5100
100WQ-50-35-115035145062%11100
100WQ-65-15-5.56515145059%5.5100
100WQ-70-7-3707145075%3100
100WQ-70-22-117022145070%11100
100WQ-80-9-4809145062%4100
100WQ-80-20-7.58020145071%7.5100
100WQ-100-7-41007145075%4100
100WQ-100-15-7.510015145070%7.5100
100WQ-100-22-1510022145061%15100
100WQ-110-10-5.511010145067%5.5100
100WQ-110-15-7.511015145075%7.5100
150WQ-130-30-2213030145069%22150
150WQ-140-7-5.51407145079%5.5150

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Rotary vacuum pump does not meet the requirements of vacuum, what are the reasons?
1) oil rotary vane vacuum pump is too low, no effect on the oil seal exhaust valve, rotary plug to refuel after large exhaust sound, and oil mist, that the level is too low, the gas can be eliminated.(2) the vacuum caused by the condensable steam pollution of oil should be changed, and new vacuum pump oil should be replaced.
Q:How about the depreciation of vacuum pumps?
(five) electronic equipment, for 3 years.The depreciation period of a vacuum pump can be calculated for 5 years. The expected residual rate is generally 5%, or it can be estimated by itself.
Q:What is the series of pumps? What's the difference between a unipolar and a multistage?
A single-stage pump is a pump with only one impeller. 2, a multistage pump is a pump with two or more impellers. The multistage pump can increase the pressure and lift the head higher. Level 1 means a booster impeller.
Q:Why adjust the centrifugal pump outlet valve can adjust the flow?
This method can be used to regulate flow. The advantage is that it is simple and easy to use and the disadvantage is that the throttle consumes energy
Q:Filter backwash pump for what use, what is the principle of work ah?
But the reverse cleaning can not completely regenerate the filter medium, or there will be some impurities remain, when the regeneration of residual impurities (pressure drop) to set the value, you need to replace the filter (filter media).
Q:The difference between submersible pumps and centrifugal pumpsWhat's the difference between the two? What is applicable and what?
1. submersible pumpsA very wide range of water treatment tools. Unlike ordinary water pumps, it works underwater, while the pump works mostly on the ground.The working principle of submersible pumpBefore the pump is opened, the suction pipe and pump must be filled with liquid. Open the pump, the impeller rotating speed, which leaves the liquid together with the rotation under the action of centrifugal force, the left outside impeller injection, injection of the liquid in the pump shell gradually slow the spread of indoor speed, the pressure gradually increased, and then from the pump outlet, the outflow discharge tube. At this time, in the leaves at the center of the vacuum area of low pressure liquid was thrown to the surrounding formation there is no air and no liquid, liquid pool at the surface of the liquid under the action of atmospheric pressure, through the suction pipe into the pump, the liquid is continuously pumped up from the liquid pool is also continuously from the outflow discharge tube.Basic parameters of submersible pumpIncluding flow, lift, pump speed, matching power, rated current, efficiency, diameter and so onSubmersible pump main application and scope of applicationIncluding construction, construction, drainage, agricultural irrigation and drainage, industrial water recycling, urban and rural residents cited water supply, and even rescue, disaster relief and so on
Q:What is the difference between an air pump and a water pump?
A pump is a machine that transports liquids or pumps liquids. It will be the prime mover of the mechanical energy or other external energy transfer to the liquid, the liquid energy increase, mainly used to transport liquids including water, oil, alkali liquid, emulsion, suspension emulsion and liquid metal, but also transport liquid, gas mixtures and liquids containing suspended solids.
Q:What are the characteristics of a pipe shield pump?
According to the transmission of liquid temperature, pressure, viscosity and particle level have different requirements, the pump can be divided into the following types: first, the basic type (standard type) transport medium temperature does not exceed 120 degrees, the head of not more than 100m, the pump other types are variations on the basic type and improved.
Q:How should the water pump be installed?
(8) check the suitability of the foundation and whether the size of the foundation corresponds to the size of the pump.(9) find the position of positive pump and motor, pump set and anchor bolt and the inlet and outlet flanges, to ensure that the flange torque of the pump conforms to the standard. Check the inlet and outlet piping before alignment. Make sure the weight of the inlet and outlet pipe does not exert force or torque on the pump. When looking for, should also pay attention to eliminate the pump rotor movement, so as to avoid the end gap error. If checked after the pump is working, it should be carried out under cold condition. It is important to draw attention to the fact that the pump set of the complete set of factory is only rough looking (checked with a ruler) when it is shipped. It may cause displacement when it is transported.
Q:Double floor sewage pump circuit diagram of a small problem
Question 4 when you need backup, you need to switch the SA switch, but where you want it. For example, when the 1# pump is running and does not reach the high water level, the 2# pump will not operate. If SA is placed in the left position, 21 and 22 are connected, and the KT is electrically delayed, and the KAB action causes the 2# pump to function. After the KAB operation, the KT will be disconnected, restored to the ready state, and also convenient for KT to restart the power on time, and also avoid the time relay to work on a long-term basis.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range