Submersible Sewage Cutter Pump Sewage Water Pump

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

  Submersible Sewage Cutter Pump Sewage Water Pump


Application

This series pump is widely used for sewage treatment of city construction discharge for architecture projects, hotel, mine, pond, dyeing and printing, paper making and textile industries.

It is the ideal tool for transportation of sludge, slurry, living sewage, feces and stale wastes, solid grains fiber, paper chips, sandy soil etc.



Model Description


100WQ 50-30-5
100: Drain aperture (mm)
WQ: Submersible sewage pump

50: Capacity (m3/hr)
30: Head (m)
5: Power (kW)

Operations Conditions


1. The medium temperature should not be over 60oC, the density 1200Kg/m3, and the pH value within 5-9.
2. During running, the pump must not be lower than the permitted lowest liquid level.
3. Rated voltage 380 V, rated frequency 50 Hz. The motor can run successfully, only under the condition the deviations of both rated voltage and frequency are not over ± 5%.
4. The maximum diameter of the solid grain going through the pump has not to be larger than 50% of that of the pump outlet.


Picture

 Submersible Sewage Cutter Pump Sewage Water Pump

Why choose us

 High Quality
1.Exported to 58 Countries
2. More than 90% customers make payment before meeting us!
3. Reorder rate up to 80%
4. Never sell any renewed pumps
5. Focus on middle and high-end market,we never seize market by using inferior material

FAQ

1. How to get our quotation in time, pls answer following questions:
    1)What liquid do you transfer?oil ,food or corrosive chemical liquid,with solid particle or not and so on 
    2) What's the flow or capcity (m3/h, L/m)? 
    3) What's the discharge head (m, feet, Mpa, bar )
     If you do not have any request, we will do as our normal standard.
  4) Contact us by under  business card information
2.OEM: Ok 
3. MOQ: 1set
4. Package: Standard export wooden case(also according to your requirements)
5. Shipping ways: By sea, By air, By express
6. Lead time: 3-15days
7. Warranty Period: One year, except spare parts 

 



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:My 1998 GMC Yukon is leaking water out of the tail pipe.?
not water pump / lol its ok
Q:replaced water pump on lower unit .?
It shouldn't take long for the water to come out. Make sure the site tube isn't plugged up. If not, check your installation out.
Q:Can the water from the fire pump enter the roof fire tank? Why?
Fire water pump water can not enter the roof, fire water tanks, "construction regulations" and "high regulations" clearly defined. The roof fire water tank acts as a temporary fire fighting water for 10 minutes, and the water in the fire pump is supplied directly to the indoor hydrant or sprinkler system. Roof water tank fire water can only be provided by the living pump.
Q:WATER PUMP REPLACEMENT?
if the water pump is driven by the timing belt then its a good idea to change both as the labor to get into water pump is the same as to do the timing belt. I'd spend the extra $50 for the belts and change them while I'm in there and that way you'll be ahead of the game instead of paying (or taking the time) to do it twice at two different times
Q:QDX is a submersible pump. What does "X" mean?
QDX is a submersible pump model, its specific meaning is:1.Q: submersible pump.2.D: single-phase power supply, three-phase electricity is not marked.3.X: pump, pump type is not marked.Complete submersible pump model will generally add rated flow, rated lift and motor power rating. For example: QDX40-8-1.5, meaning with single-phase 1.5KW motor, rated flow of 40 cubic meters / time, the rated lift of 8 meters under the pump submersible pump.According to the different relative position of pump and motor, submersible pump is divided into pump type and pump type. The pump submersible pump motor in the above, below, this structure greatly reduces the radial size of the pump, so much for submersible pump and small submersible pump operation. Submersible pump submersible pump on top of the pump in the following, it is divided into two types of internal and external type. The submersible pump carries the liquid through the annular flow passage around the motor, then cools the motor and then flows out of the pump outlet. Even though the pump is near the drain sump, there is no need to worry about the temperature rise of the motor, so the application is becoming wider and wider. External pump submersible pump directly from the pressurized water chamber after the impeller or diffuser outlet of discharged liquid, motor is cooled by liquid pumping. As the lower pump structure can work in a relatively shallow liquid, it is often used in submersible pumps for operating surfaces, especially the main structure of large caliber submersible pumps.
Q:How can I pump the motor insulation?
A submersible pump to shake the insulation, water pump distance more than 20 meters away from the cable distribution box is fixed, at this time to shake the insulation in the distance distribution box can only shake, disconnect the power cable is connected with the shake table, the ground end is connected with the electric box so that the pump shell shake shake, also must be reliable grounding to shake to now, the pump shell grounding not only in the water, it must be a wire connected with a shell or a wire will be immersed in water, this is right insulating shake,
Q:Power flow conversion of water pump
Pump shaft power (kw) = water supply (L / s) x lift (m) /102 * efficiency = flow * lift * density * acceleration of gravity.Explanation:102 is the unit collation constant.Pump effective power / pump shaft power = pump efficiency (general 50%--90%, large pump higher)Unit time pump liquid volume flow is, flow by Q, a unit of measure: m3 / h (m3/h), L / S (l/s), L/s=3.6 m3/h=0.06 m3/min=60L/minG=Q G refers to weight - liquid proportionThe energy obtained by pumping a liquid of a unit weight is called a lift. The pump head, including suction stroke, is approximately the difference between the pump outlet and inlet pressure. The lift is expressed in H, and the unit is m.The efficiency of a pump is the ratio of the effective power to the axial power of the pump. ETA =Pe/P pump power usually refers to the input power, the motive power to the pump shaft, it is also called the shaft power, denoted by P. Effective power is the product of pump head and mass flow and gravity acceleration
Q:Where does the water go after it is sent to a pumping station?
Potable (drinkable) water pumps placed just outside the treatment plant boost pressure in the water mains, where it eventually gets to homes, businesses and hydrants via the pipe network. Most sewers flow by gravity (downhill) to a waste water treatment plant (or septic field). But if an area is too low to be serviced by a gravity sewer, an ejector pump is set at the bottom of a collection well which pumps the wastewater to a higher elevation in a pressure pipe called a force main. A good pump station will kick on about 4 or 5 times an hour and run for several minutes. Eventually it outlets to a manhole in a gravity system and ultimately the treatment plant.
Q:I have already replaced the thermotast but my vw bug still overheats .it blows water thru the tailpipe?
Overheating can be caused by many things such as : the fan, the fan motor ,the water pump, or a fuse. Overheating is a trail an error task. since you already changed the thermosatate the next thing you need to do is check the fan motor.
Q:Could my problem be with the water pump?
If he said the temp fell by revving the engine one of two things either the water pump is going out the bearing is failing and faster RPMS is pushing the water pump inside to spin faster and the bearing is starting to catch and work and spon the propeller OR the radiator is plugged or needs to be replaced. If the radiator is going bad it could be restricting water and more RPMS once again is pushing the water through the radiator to cool it. The other thing it could be is a radiator cap if it is not holding pressure then it will cause the water inside to boil slightly and make it hotter also. I would by a new cap and do the water pump. Those are the two cheapest. If that doesn't fix it then do a radiator.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range