Submersible Pump for Dirty Water with High Quality

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
100000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

                   Submersible Pump for Dirty Water with High Quality

1.Structure of Submersible Pump for Dirty Water Description

 

WQ Series Centrifugal Submersible Pump of sewage basic dormant,along with sewage pumping,sewage things gradually deposition in the bottom of the pool. But the sediment could not force with sewage went out at the pumps normal operation of inlet water alone.So the deposit is more and more at bottom of pool,which eventually led to affect normal work of pump.Engineering clean the sewage pool regularly ,so as to avoid waste of human and material resources.We produce this kind of sewagepumps,which is mounted mixing impeller at the the bottom of pumps,along with the rotation of pump, driving the impeller highspeed mixing.Thus, stir up the deposit  of bottom, mix with water, and flow out with water.Also can match with coupler,make more quick and convenient installation and maintenance.

 

2.Main Features of the Submersible Pump for Dirty Water

• Compact structure, good appearance, low construction

Operation stably, same inlet and outlet

•Convenient installation and maintenance

•Parallel connection and have many models to be chosen for difference flow rate and head

•Horizontally and vertically installation as different pipeline system

3.Submersible Pump for Dirty Water images

Submersible Pump for Dirty Water with High Quality

4.Submersible Pump for Dirty Water Specification

 

ModelCapacityHeadSpeedEfficiencyPowerOutlet
Q(m3/h)H (m)n(rpm)η (%)Kwmm
40WQ-12-15-1.51215290048%1.540
50WQ-10-10-0.751010290054%0.7550
50WQ-15-15-1.51515290051%1.550
50WQ-15-20-2.21520290051%2.250
50WQ-17-25-31725290053%350
50WQ-20-7-0.75207290062%0.7550
50WQ-22-20-42220290069%450
50WQ-25-10-1.52510290067%1.550
50WQ-25-32-5.52532290049%5.550
50WQ-40-15-44015290076%450
50WQ-40-30-7.54030290062%7.550
65WQ-25-15-2.22515290052%2.265
65WQ-25-28-42528290058%465
65WQ-37-13-33713290060%365
80WQ-29-9-2.2299290048%2.280
80WQ-40-7-2.2407290050%2.280
80WQ-40-15-44015290057%480
80WQ-43-13-34313290065%380
80WQ-50-10-35010290072%380
80WQ-50-25-7.55025290056%7.580
100WQ-50-22-7.55022145063%7.5100
100WQ-50-35-115035145062%11100
100WQ-65-15-5.56515145059%5.5100
100WQ-70-7-3707145075%3100
100WQ-70-22-117022145070%11100
100WQ-80-9-4809145062%4100
100WQ-80-20-7.58020145071%7.5100
100WQ-100-7-41007145075%4100
100WQ-100-15-7.510015145070%7.5100
100WQ-100-22-1510022145061%15100
100WQ-110-10-5.511010145067%5.5100
100WQ-110-15-7.511015145075%7.5100
150WQ-130-30-2213030145069%22150
150WQ-140-7-5.51407145079%5.5150

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What are the advantages and disadvantages of the pump control system and valve control system in the hydraulic system?
Large pump control valve controlled energy consumption at least 30% reason is that there are serious throttling loss of a throttle valve control system of severe fever but simple structure and low cost which is why now valve control system still occupy the main market reasons.Pump control system with complicated structure especially when serious nonlinear control unsymmetrical cylinder control effect is not ideal, but the biggest advantage is energy-saving and low fever America professor Monika points out that using the pump control system of hydraulic excavator energy efficiency compared with the valve control system can be improved by over 46% but costs are high. But in control, the three pump invented by Professor Quan LONG of China is a good solution. LZ can find the invention patent or find his paper on sage. It seems that there are three or four SCI about this pump
Q:What is cavitation, centrifugal pump cavitation phenomenon how to solve?
The pump is in operation, if the over-current part of the local area (usually the impeller blade inlet somewhere later) for some reason, the absolute pressure of pumping the liquid was reduced to liquid vapor pressure temperature, liquid vaporization began in the area, produce a lot of steam, forming bubbles, when the liquid contains a lot of bubbles forward by high pressure impeller zone, high pressure liquid around the bubbles in the bubble decreases drastically and rupture. Condensation in the bubble burst at the same time, the liquid particle filled hole at a high speed, this moment has a very strong effect of water hammer, and with a high impact frequency against the metal surface, the impact stress of hundreds to thousands of atmospheric pressure, impact frequency can be up to tens of thousands of times per second, serious breakdown when the wall thickness will be.The process of cavitation in a pump is caused by the bursting of bubbles and bubbles in the water pump and the destruction of the over-current components. Water pump cavitation, in addition to the over-current components will have a destructive effect, but also noise and vibration, and lead to the performance of the pump down, seriously when the pump will be interrupted liquid, can not work properly.
Q:What is the series of pumps? What's the difference between a unipolar and a multistage?
Each impeller is of the first stage. (two impellers share only one level, and exit is only level one)
Q:How do vacuum pumps and pumps work together?
The role of the check valve:"[the water pump impeller is not closed" refers to the pump suction pump before the water without water inlet pipe and water outlet pipe gas should be connected] is a connector, a connector, still can make the level surface, in order to prevent the water flow along the pipe, until it reaches the level of the flush, then increased check valve, or pumping up water will not leak?Vacuum suction principle of self suction pump:Assuming that the pump connected with the water inlet of a sealed container, the container has plenty of water, since the start of a water pump, water is thrown out of the water impeller pump body, water inlet seal vessel due to the extraction of water to form a vacuum cavity, this assumption will be connected to vacuum cavity and exposed to atmospheric conditions of water, water at atmospheric pressure under the effect of entry into the vacuum chamber".....
Q:If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
If the fish tank is made of metal, the fish tank is grounded or connected to the zero line, and then the fire line is put into the water, then your fish will be electrocuted immediately. Go back to the submersible pump, submersible pump line and the zero line very close, even if the firing line and the zero line at the same time the leakage occurs, fish could not swim between the firing line and the zero line, so the tank submersible pump leakage will cause the following hazards: 1, electric shock. 2, submersible pump short circuit. 3, the submersible pump serious fever, resulting in water temperature tank.
Q:Because the water pressure of the booster pump is not enough, it can not work automatically. It can only be operated by hand. It is inconvenient to use.
One possibility is the automatic type household booster pump used for a period of time, automatic failure phenomenon, it is mainly stainless steel and other metal products in pipes, long-term precipitation to shut off the power supply after unloading, unscrew the top screw, remove the plastic sheet to be cleaned, and then, according to the original reset, the normal debugging. Can be re used. But that's not why if your booster pump isn't working properly all the time.
Q:What is a feed pump?
In general, high lift pumps are required with a front pump (which is similar to the feed pump of the landlord) or a low position;
Q:What's the difference between a centrifugal pump and a centrifugal pump? What are they used for?
Centrifugal pumps are used to transport liquids (or mixtures, waste water, waste materials) from one location to another.
Q:How can the submersible pump level meter be connected?
Installation of submersible pumps dedicated liquid level float, connected to the submersible pump power line (some submersible pumps bought with), or received submersible pump control circuit, high starting, low stop.
Q:The distance from the pump button to the ground
After confirming that the fire pump has started running, issue a command signal to the hydrant button to light the green answer light.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range