submersible motor pump Amarex KRT INDUSTRY H, C1, C2
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 pc
- Supply Capability:
- 1 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Design
Vertical, single-stage submersible motor pump made of wear-resistant industrial materials in close-coupled design, various impeller types, for wet or dry installation, stationary and transportable version. Design to ATEX.
Applications
Handling of all types of abrasive or aggressive waste water in water and waste water engineering as well as industry, especially untreated sewage containing long fibres and solid substances, fluids containing gas / air, as well as raw, activated and digested sludge; sea water desalination.
Overview of technical data
Type of impeller | Open; Multi-vane impeller;Radial;Closed;Free flow impeller |
Type of installation | Close- coupled |
Maximum drive rating | 200 kW |
Impeller material (EN standard) | JN 3029; 1.4517 |
Type of bearing | Rolling element bearings |
Drive frequency | 50 Hz / 60 Hz |
Maximum speed of rotation | 3. 500 1/min |
Maximum flow rate | 2. 400 m³/h |
Maximum discharge-side pressure | 10 bar |
Casing material (EN standard) | 1. 4517;JN 3029 |
No. of impeller entries | Single entry |
Casing material | White cast iron; Cast duplex steel |
Suction characteristics | Non- priming |
Drive voltage | Low voltage |
eClass assignment | 36410103; 36410101 |
Pump set location | Wet well |
Explosion protection | ATEX II 2 G T3; ATEX II 2 G T4 |
Max. permissible fluid temperature | 60 °C |
Free passage | 120 mm |
Main applications | Water; Oil / Gas;Energy;Industry and process engineering;Mining / Dredges;Waste water / sewage |
Type of installation | Stationary; Transportable |
Type of casing | Volute casing |
Type of connection | Flange |
Type of lubrication | Oil lubrication |
Type of drive | Electric motor |
Installation position | Vertical |
Shaft material (EN standard) | 1. 4462;C45+N |
Type of coupling | None |
Shaft seal type | Mechanical seal |
Drive | Electric motor |
Maximum head | 100, 00 m |
Maximum rated pressure (discharge) | PN 16 |
Nozzle position | End suction |
Casing partition | Radially split |
Connection to power supply | < 690 V, 3~ |
- Q:Does the reservoir water heater press the booster pump (high marks)?
- The outlet water pressure of hot water is the same as that of cold water. The water heater is pushed by cold water to push out the hot water. (of heating). Installation location about 2 meters away from the ground, the impact of water pressure is not large, in rural areas, the installation position in more than two buildings will have an impact. In the city, the installation position is above four floor to affect the water pressure.
- Q:Working principle and diagram of axial piston pump with pressure compensation variable
- The size of the outlet flow pressure compensated variable displacement pump with outlet pressure of approximately in a certain range according to the constant power curve. When the pressure oil from the main part of the channel (a), (b), (c) into the inferior vena cava (d) variable shell, oil by the channel (E) respectively into the channel (f) and (H), when the spring force is greater than the oil (f) into the lower end of the piston ring servo hydraulic thrust area when the oil liquid (H) to the chamber (g), push the variable downward movement of the piston, the pump flow increases. As for the hydraulic servo piston end thrust force ring shaped area is greater than the spring when the servo piston moves upward, blocking channels (H), the (g) (I) through the cavity of the oil cavity pressure relief, at this time, the piston moves up, the variable head angle decreases, the pump flow rate decreases.
- Q:How can I buy a pump?
- 3 、 mechanical requirements of high reliability, low noise, vibration.4, the correct calculation of pump procurement costs, the pump manufacturer to inspect, requiring good quality equipment, good after-sales service, spare parts can be timely supply.The micro pump and the motive of the mechanical energy or other external energy transmitted to the liquid, the liquid energy increase, mainly used to transport liquids including water, oil, alkali liquid, emulsion, suspension emulsion and liquid metal, but also transport liquid, gas mixtures and liquids containing suspended solids.The technical parameters of pump performance include flow, suction, lift, shaft power, water power, efficiency and so on.
- Q:How to install, operate and maintain the pipeline booster pump?
- Should be "People's Republic of China network security law" requirements, since June 1, 2017, the use of Internet services to carry out real name authentication account. In order to ensure your Baidu account can be used normally, please check the account number as soon as possible. Thank you for your understanding and support.How to install, operate and maintain the pipeline booster pump?Brother Yao s Gc76 2547 | browseRecommended for 2016-12-01 23:52:54 best answerThe installation of booster pump must be installed horizontally or vertically according to the installation method. The direction of flow shall be consistent with the arrow on the pump body, and installed as far away from the water level as possible. A valve shall be installed on the pump inlet line for ease of use and maintenance. When the impeller is the aspiration level below the pump on the pump shaft end or around the pump should be installed check valve, the outlet is connected with 13 links for water use, at first use to pump should be filled with water, and tighten the screw plug. The pipe connection should be tight, especially the water inlet pipe can not leak, otherwise it will reduce the pump head or not pumping water. The pump cavity is not water, not a long time running, so as not to damage the seal
- Q:I want to know the concrete under 60 type pump performance, it is mainly the pump long spiral bored piles, such as the diameter of the pump, transportation distance, pumping height and so on, thank you!
- Specification for concrete cylinders:Bore * stroke mm 200 * 1650Hopper capacity L 800Feeding height mm 1400Motor model Y2-280M-4Power kw 90Rated voltage V 380Rated speed r/min 1480Soft starter withoutHydraulic system open-loop
- Q:Operating procedures for measuring pumps
- Pressurization(1) for the discharge pressure below 2.0MPa, then the pump stroke length should gradually increase, each increase of 20%, to maintain 15 minutes.(2) for the discharge pressure greater than 2.0MPa, you need a special pressure, to ensure that the pump discharge pressure gradually increased, each time for the final row pressure of 20%.(3) when the pressure is not increased, the stroke of the pump is gradually increased by 20% strokes per time.Note (1) when pressure is applied, the pressure gauge should be observed at the side of the loading side (slow motion)(2) check ammeter, forbid overload
- Q:Suction stroke and lift of water pump
- For example: there is a kind of water pump, the model is called "BSP" series, the volume is not large, but the nominal suction process can be 4 meters, it can not add water to 4 meters, it is considered to be relatively high in the micro pumpIn micro pumps, not all pumps have self-priming capacity ("suction stroke")Some centrifugal pumps there is no self-priming ability to use must first do add water. Although some micro pump with self absorption capacity, but "suction" are often the subject of "and the water inlet pipe in all air, can smoke the vertical height of water gap, even only half not so. The pump selection, the absorption process is a relatively important parameter.
- Q:What is the main difference between SK water ring vacuum pump and 2BV water ring vacuum pump?
- The unified corrosion resistant design of bronze impeller improves the corrosion resistance of the pump, and the stainless steel material is more suitable for more severe applications;
- Q:Why should the pump be closed when the centrifugal pump is started?
- Centrifugal pump has an important characteristic: when the pressure (head) is very low, the flow will be great, which can be seen from the characteristics of the pump curve. While the pump power is directly proportional to the flow rate, pump start, no pressure in the pipeline, caused by the pump flow, high power pump, and the pump motor, the rotating part from rest to high-speed operation, need a lot of acceleration, it will cause a great starting current
- Q:How long does the fine stone pump need maintenance? What should I pay attention to?
- nan
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us