Steel Structure Drywall Profiles on Canton Fair

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
10000 pc
Supply Capability:
3000000 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Description: 

 

1.Superposition joint part between main carrier and vice carrier or vice carrier and carrier is called point lap.

2.It uses lap structure to assembly, connection between joints dovetail very well. The joint face unknits and have a nice appearance.

3.There is a barb at the vice carrier joint, it can avoid loosing and falling from the infection of outside force.

4.Soleplate of main and vice carrier is zincification armor plate, which meets the national GB standard demand. We use baked paint zincifcation armor plate as baked paint panel,whoes capacity of zincification is high. It meet the national GB standard demand.

5. Raw Meterial is galvanized steel with 80-100g/sqm

Specification:

Specification for middle east:

Main Channel

38x12 mm

Furring Channel

68x35x22 mm

Wall angle

25x25 mm

C stud

50x35 mm

C Stud

70x35 mm

C stud 

75x35 mm

U track 

52x25 mm

U track 

72x25 mm

U track  

75x25 mm

 Specification to Australia:

top cross rail

25x21x0.75 mm

25x21x0.75 mm

Furring Channel

28x38x0.55 mm

16x38x0.55 mm

Furring Channel track

28x20x30x0.55 mm

16x20x30x0.55 mm

Stud

64x33.5x35.5 mm

76x33.5x35.5x0.55 mm

Stud

92x33.5x35.5x0.55 mm

150x33.5x35.5x0.55 mm

Track

51x32x32, 64x32x32x0.55 mm

76x32x32x0.55 mm

Track

92x32x32x0.55 mm

 

Specification to Europe, Russia, UKrain, Georgia. etc

  

C Stud

60x27 mm

U track

28x27 mm

C stud

50x50 mm

C stud

75x50 mm

C stud

100x50 mm

U track

50x40mm

U track

75x40 mm

U track

100x40 mm

 

Product Overviews

Steel Structure Drywall Profiles on Canton Fair

 

 

Steel Structure Drywall Profiles on Canton Fair

Steel Structure Drywall Profiles on Canton Fair

 

FAQ

1.Sample: small sample can be offered by free

2.OEM: OEM is accepted

3.MOQ: small order is ok

4.Test: any third party is accepted to test

5.Factory: Can visit factory any time

6.Delivery Time: small order is within 7days or according to your order

 

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Light steel keel wall circuit how to wear pipe
Separate the laying of the wall: According to the architectural design, in the indoor floor of the floor wall and the edge of the line, and cited to the two main structure of the wall and the bottom of the floor, while pop the door and window hole line.
Q:Light steel keel partition wall construction process is what
Processes: Bracket, Divider Pillow Pillow (Design Required) Fixed along the top, along the keel fixed Bone keel installation Vertical keel installation door, window frame installation Additional keel installation Support keel, check keel installation Electrical pipe , Installation of the installation of the wall equipment, a cover panel filled with sound insulation material installation, the other side of the panel panels and corners of the treatment of quality inspection.
Q:How to fix the middle of the light steel keel to the roof and the ground, the keel has a joint?
If it is looking for decoration workers to do, then they are professional. Under normal circumstances is the use of surge tube and self-tapping screws fixed. (There are other ways). Keel specifications a lot, generally long after the increase in joints. What specifications of the keel with what specifications of the joints. Not common.
Q:On the decoration of the partition and the floor of the problem?
With the filling block wall, and the same brick with the nail what is no problem, the weight is not heavy, the thinnest filling block is 120 thick, even the total thickness of double-sided plaster does not exceed 180, or light The partition wall is also the line, faster, but also durable, more than gypsum board wall to spend more, but at least the first nibbling nails are no problem, more durable and reliable, the weight is also light, the normal stay on the trip.
Q:Gypsum board partition wall how to sound insulation
Single-walled wall due to the law of quality constraints, must be a heavy wall in order to obtain good sound insulation performance. For the office partition wall, in order to meet the national minimum standard rw = 40db requirements of single-layer partition at least 100kgm2 above the surface density (surface density is the weight per square meter of the wall). If the wall is divided into two or more layers, the sound insulation will be significantly improved.
Q:75 light steel keel wall to do 6m high, need reinforcement? How to strengthen?
Must do 75 keel, it is recommended to add angle iron or square tube reinforcement, do not forget to do heart keel
Q:The room to remove the partition, can not retain the original light steel keel gypsum board ceiling?
But this will be more expensive construction costs
Q:Home to decorate the ceiling, playing the wall, I learned from the market can be resistant, dragon card, Saint Gobanchenko these brands of light steel keel gypsum board which good point?
You said these are very good brand, Saint-Gobain and Long card companies with more. The material is on the one hand, the ceiling is the most important woodworking craft and craftsmanship. Material is not a problem
Q:Lightweight wallboard light steel keel how to construction
Damp room and steel plate plaster wall, light partition board keel spacing should not be greater than hundreds of millimeters, the installation of supporting keel, the support card should be installed in the direction of the vertical keel opening, partition wall card should be four hundred To six hundred millimeters, from the keel at both ends of the distance should be twenty to twenty five millimeters, should be fixed according to the location of the ball along the edge, along the keel and border keel, keel line should be coincident with the line.
Q:Can my light steel keel ceiling withstand the weight?
Light steel keel with superior and non-superior type. 50 light steel keel is not on the man's 50mm * 19mm * 0.5mm man's 50mm * 20mm * 0.6mm main keel man 60 * 27 * 1.2. In addition, the keel of the outer keel does not require less than 600 * 600, and the mandarin keel is usually not less than 400 * 400 according to the load. Compare your material to see what specifications the keel is. Baidu may wish to look at these two types. If it is superior type, there is no problem

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range