Standard Hot Dipped Galvanized Wire For Chain Link Fencing

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Commercial Galvanized Steel Wire

(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .

(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .

(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.

(4) Tensile Strength Range

Size (mm)

Tensile Strength (mpa)

0.15-1.60

290-550

0.65-1.60

400-550

1.61-6.00

400-1200

(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.

(6) Packing

Size (mm)

Coil Size

Spool Packing

Big Coil Packing

ID (mm)

OD (mm)

0.15-0.26

6 inch

1-14kg/spool

0.27-0.60

8 inch

1-100kg/spool

0.61-1.60

12/14/16 inch

1-100kg/spool

250-400

400-770

1.61-6.00

14-500kg/spool

450

800

508

840


(7) Zinc Coating

Meet GB/T 15393 standard.

Size (mm)

Weight of Zinc-Coating ( g/m2 )

A

AB

B

C

D

E

F

A1

B2

0.25

30

20

18

>0.25-0.40

30

25

20

>0.40-0.50

30

20

>0.50-0.60

35

20

>0.60-0.80

120

110

40

20

>0.80-1.00

150

130

45

25

>1.00-1.20

180

150

50

25

>1.20-1.40

200

160

50

25

>1.40-1.60

220

180

50

35

30

>1.60-1.80

220

180

70

40

30

>1.80-2.20

230

200

80

50

40

>2.20-2.50

240

210

80

55

40

>2.50-3.00

250

230

90

70

45

>3.00-4.00

270

250

100

85

60

30

>4.00-5.20

290

270

110

95

70

40

>5.20-6.00

290

270

245

110

100

80

50


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Wireless or Wired Internet?
Wired is faster and higher quality, but wireless is more convenient. The modem generally does not provide wireless connectivity. Most modems (cable or ADSL modem) provide a single Ethernet connection. To get a wireless setup, you need to connect a wireless router to the modem. The router should provide both wired and wireless connections.
Q:Is there a way to connect a 3-wire thermostat in a 2-wire house?
Connect a new piece of 3 wire to the existing 2 wire and pull it through the wall by pulling the 2 wire. Of course if it gets stuck you will need to measure how far you pulled to know where to cut a hole in the wall. Cutting a hole in the wall if needed, isn't a big deal you just put the piece back, screw or nail it down (cut so you have studs on both sides to reattach it later) tape and plaster and paint.
Q:Remote wire for car subwoofer?
It'll more than likely be a blue wire with a white stripe coming off the back of the aftermarket deck.
Q:Baking Bendy Wire in Baking Clay?
If you are referring to using a metal armature inside Sculpty, then No it will not burn the clay. You do need to follow the baking instructions though. It will bake just fine and you will be surprised how strong the sculpture is after baking.
Q:Telecaster Wiring Guide?
And it is hundreds of similar resources, which may indicate you haven't really used the search engines. Just enter search terms like: telecaster wiring, guitar wiring, guitar schematics, guitar wiring diagrams and so on.
Q:What is the current in the wire?
Wiring that previous could desire to get replaced. Insulators wreck down over the years. In Edison's day insulation became into, rope and tar, or fabric, with glass insulators to guard lumber. you like a rectifier to create pulse ac (see image voltaic Panel grant) i hit upon it not straight forward to have faith anybody might grant DC power. The generator could desire to be on the threshold of factor to apply, do to severe voltage drop in DC cutting-edge over long distance. through fact of this AC is used now. till that's an Edison Museum image voltaic power is DC too. I advise studying image voltaic power for ideal DC wiring practices. I actual have been a electrician my total existence and know little or no approximately DC wiring and contraptions. in case you presently have electrical energy, get multimeter attempt for ac voltage first. then DC to steer away from unfavorable the meter, to confirm what power you have
Q:Updated 2 wire ungrounded residential wiring?
You can just add a wire. If you have metal conduit and metal j-boxes all you have to do is connect a ground to the box. NEC 250.118 Types of Equipment Grounding Conductors. The equipment grounding conductor run with or enclosing the circuit conductors shall be one or more or a combination of the following: (1) A copper, aluminum, or copper-clad aluminum conductor. This conductor shall be solid or stranded; insulated, covered, or bare; and in the form of a wire or a busbar of any shape. (2) Rigid metal conduit. (3) Intermediate metal conduit. (4) Electrical metallic tubing... But if not in metal conduit then you can connect it to the first 5 feet of metal water pipe, the ground rod, the wire leading to the ground rod/metal water pipe, or the ground bar in the source electrical panel. NEC 250.130(C) Nongrounding Receptacle Replacement or Branch Circuit Extensions. The equipment grounding conductor of a grounding-type receptacle or a branch-circuit extension shall be permitted to be connected to any of the following: (1) Any accessible point on the grounding electrode system as described in 250.50 (2) Any accessible point on the grounding electrode conductor (3) The equipment grounding terminal bar within the enclosure where the branch circuit for the receptacle or branch circuit originates (4) For grounded systems, the grounded service conductor within the service equipment enclosure
Q:Oz vs. The Wire?
The Wire by far. Who wants to watch a bunch of inmates sodomizing each other?
Q:0 gauge power wire with 4 gauge ground?
all okorder.com/... or going into your audio dealer store asking for 3 to 5 ft of the 0 gauge wire for around 15 to 20 dollars at the max. you can also asking your friends for if the person has some extra wire willing to sale it for cheap, I totally would do it, and I have done that before.
Q:How do I close off exposed wires...?
Are they in an electrical box,or just hanging there? Either way, you need to twist them (individually) screw the proper sized wire nut on to them, then wrap some electrical tape around them. If they have a box, you can just put a cover on it. If they are just dangling out of the wall,( very unusual,but you never know) Just put a plain cover over them, after wrapping them. After they have been wrapped separately, it will be safe to turn the breaker back on. Use a electrical tester before touching any electrical wiring,even after you think you have turned the breaker off. I almost killed myself thinking the breaker I shut off lead to the particular wire I was working on. Come to find out, a switch to a light, and an outlet not more then a foot away from that ,were pigtailed on to separate circuits. Don't ever guess, or assume nothing when working around electricity. Byee

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range