• Stainless Steel Sanitary Fitting Reducer DN65x50 V Profile 304 System 1
  • Stainless Steel Sanitary Fitting Reducer DN65x50 V Profile 304 System 2
Stainless Steel Sanitary Fitting Reducer DN65x50 V Profile 304

Stainless Steel Sanitary Fitting Reducer DN65x50 V Profile 304

Ref Price:
get latest price
Loading Port:
Huangpu
Payment Terms:
TT OR LC
Min Order Qty:
50 pc
Supply Capability:
100000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

WELCOME to visit our stainless steel pipeline products here(^_^)

Press fitting system joins pipe without welding or bolting. The components fit by crimping through the use of a special pressing tool. An O-ring that is inserted in the fitting ends of the pipe ensures a leak-proof connection. Press fitting system is the trend of pipeline industry. It is widely used in cold and hot water supply, heating supply, fire protection, medicinal gas, industrial petroleum pipeline system etc.

For the size, now we have 3 series:
1. Out diameters: 16.0, 20.0, 25.4, 32.0, 40.0, 50.8, 63.5, 76.1, 88.9, 108.0 (GB/T 19228.2-2011)
2. Out diameters: 15.88, 22.22, 28.58, 34.0, 42.7, 48.6, 76.1, 88.9, 101.6 (JIS G3448-1980)
3. Out diameters: 15, 18, 22, 28, 35, 42, 54, 76.1, 88.9, 108 (EN 10312:2002)


Stainless Steel Sanitary Fitting Reducer DN65x50 V Profile 304

Stainless Steel Sanitary Fitting Reducer DN65x50 V Profile 304

Stainless Steel Sanitary Fitting Reducer DN65x50 V Profile 304


Technical information:
-- Material: Stainless steel 304 and 316L available.
-- Max working pressure 1.6MPa (equal to 232 psi), testing water pressure: 2.5MPa (equal to 362.5psi).
-- Working temperature from -20 to 110 degree centigrade (with Chlorinated butyl rubber O ring),
-- Suit medium: Cold water, hot water, compressed air, gas, oil etc

The product features as below: 
1, thin wall stainless steel pipe could last for 70 years, it is the same life time with normal buildings. 
2, no smell, no rusty. 
3, recycle material
4, avoid welding, avoid fire dangerous. 
Contact us for more details!

Q:I have a pathfinder with an annoying alarm. If I take ou the Horn fuse will the alarm stop going off. It is SOOO loud that people at work and in my apartment complex want to gag me and kill me - but don't want to pay 50 bucks to have it shut off. Or what fuse number would it be?? It was already there and i bought it used, so there's not a manual.Thanks for any feedback!!!
you have to pull the steering off and put another turn signal switch in.
Q:If ghosts are said to give off cold spots, how come when a ghost appears on a thermal imaging device, the area is hot/warm?
You can fill the strike in the door jamb. If the hole in the strike plate that is in the door jamb is filled to the top, level, the latch wont engage.The handle will still feel locked, but a push on the door will open it. You could cut some hard cardboard sheets the size of the hole, use whit glue and stack them up until the hole is filled. Then lock the lock and shut the door. If you filled the hole all the way the door should just push open. Also you can try duct tape to cover the hole, but it would be more noticeable.
Q:What is a more rugged trip: Alaska or Boston?
1 meter 3.2809 feet 3.2809 ft X lbf/ft? / 62.4 lbm/ft? 3.2809 ft x 62.4 lbm/ft? 204.72816 lbf/ft? 204.72816 lbf/ft? / 144 in?/ 1 ft? 1.421723 lbf/in? Since there is a hydrostatic head of 1.421723 psi per meter of elevation, they want a 4 psi increase per meter elevation to ensure sufficient flow and to take into account any minor additional head losses (due to piping length and any equivalent lengths for fittings and friction factor) to the point of delivery. The diameter is important due to friction head losses over a long length of pipeline and the Darcy-Weisbach equation applies. I responded to a similar inquiry regarding static head loss over a long length of pipeline. Edit: I forgot to mention that there are many tables which apply Hazen-Williams equation for head losses specifically for water piping systems. This approach is probably more appropriate for your water delivery design work. Both the Darcy-Weisbach and Hazen-Williams equations require the inside pipe diameter.
Q:Maintenance skills of fire hose clamp joint leakage
Detailed explanation of maintenance technology for fire hose clamp joint leakage:Trench type fire pipeline after used for a long time, if all of a sudden pressure relief after prone to the displacement of the pipeline caused by clamp joint Water Leakage, by tightening the clamp bolts do not necessarily have a good effect, because of aging, lack of elastic rubber ring.
Q:the lightning theif? is it any good? whats it about??
call a wholesale house that sells fittings and pipe they usually have pamphlets that have these dimensions Grinnell has one or a pipefitter handbook
Q:What is the manual pre assembly procedure for the EO-2 joint?
I. pre assembled1, EMB card sleeve type pipe joint pre assembly of the most important link, directly affect the sealing reliability. A dedicated preprocessor is usually required. The small diameter can be pre joint in a vise. The concrete method is to use a joint as the mother's body and press the nut and the sleeve onto the tube. The utility model mainly comprises a sleeve type through pipe joint, a clamping sleeve type end through connection head, a clamping sleeve type three way pipe joint and other patterns. I found that even if the same manufacturer of a batch of goods, the cone of these joints on the depth of the hole is often different, resulting in a leak, and this problem is often neglected. The correct approach is to connect the end of the pipe with what kind of joint, and the corresponding connection ends are prefabricated with the same type of joint, so that the leakage problem can be avoided to the maximum extent.
Q:i hear noise from the front suspension and is mostly from the drive side . when i bought the car the inner cv boots were torn so i had both axles changed as well as both outer tie rods and the left inner tie rod only. also i have changed the sway bars and the bushing for the front struts. the noise still there but i feel like the has been a little reduce in the noise but still i can hear it almost as loud!!! we even checked the hood, the air pressure in tires to see if they are the reasons for that noise but the answer was no!.on high speed i cant hear the noise, only when i drive in the city and if the roads have a lot of small bumps i can hear it but when i go on big bumps like speed bumps i dont hear the noise really! the mechanic shop tested drive my car and took my struts out and said they look worn out but still doing their job and there is no leak from the struts. and they said the arm controls look fine too. so i really want to know what produces the noise!!!???
This Site Might Help You. RE: What are all the things Benjamin Franklin Invented? like the lightning rod.
Q:With 304 stainless steel card sleeve pipe joint with stainless steel pipe, the stainless steel pipe material what kind of requirements, can withstand the work pressure?
I personally think that the installation problem, that is, the card sleeve and steel pipe only after installation to reach the sealing effect, the installation quality can not meet the design pressure requirements.To avoid this situation, it is recommended that after installation 1.25 times higher than the design pressure test, test pressure can be put into use
Q:Best Answer will get 10 points !!Ok I have a Whirlpool LEC8858EQ0 DryerIt Starts and Runs for about 10 mins then shuts off, It was making a bit of a louder noise recently, it will stay off and then all of a sudden as long as the knob is still on the dryer selection it will come back on, (Maybe after it cools)Do /Should I replace the Thermal Fuse ?Id like to replace the whole damn thing but I cant I dont have the money, and the room is built around the machine so that creates another HUGE problem.Does anyone have any suggestions ? I opened it up cleaned out any dust and lint and Im thinking maybe the thermal fuse ?PLEASE HELP BEST ANSWER GETS 10 !!
What makes her think it is related to the silver ? What exactly is happening ? Is it slow to drain or is water backing up in the sinks or? You can remove the traps under the sinks ( just unscrew the fittings ) and see if there is anything clogging it in there, otherwise post again and specify exactly what is wrong with the plumbing and how many fixtures are affected.
Q:I need to make my day more interesting!
All I know is that this question definitely does not belong under search engine optimization.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords