Product Description:

Specifications

1.Stainless steel oil transfer gear pump
2.Small pump with a portable handle
3.Transfer oil, lube liquid
4.Widely used

Packaging & Delivery

Packaging Detail:Carton with foam or plywood case.
Delivery Detail:The delivery time depends on the quantity.

Specifications

1.Stainless steel oil transfer gear pump
2.Small pump with a portable handle
3.Transfer oil, lube liquid
4.Widely used

WCB Stainless steel oil transfer gear pump

Product Introduction:

1. WCB Stainless steel oil transfer gear pump is a small gear oil pump with a portable handle.

2. This series of pump is always used to delivery lubricating liquid, but by adopting stainless steel material, it also works for medium that is non-lubricating oil, beverage or corrosive liquid.

3. With the merits of small volume and easy to move and carry, pump has always been used in oil drum carrier, oil refinery, electric power plant and substation and oil depot.

4. The voltage and frequency could be customized to meet customers' requirements.

Product details:

Working Principle:Double Gears
Main applications:       Oil
Driver:Electric motor
Power Specs:380/415 V 3phase; 110V/220/240 V 1phase;50hz/60hz,etc
Max. permissible fluid temperature:120°C(248°F)
Type of connection:Thread, Quick couple.
Installation position:Horizontal
Casing parts material:Cast iron, Stainless Steel
Shaft seal type:  Shaft seal ring
Free passage:00 mm
Maximum viscosity:300C.S.T
Maximum drive rating: 1.1kW(1.5HP)
Maximum caliber:  25mm(1inch)
Maximum discharge-side pressure:0.3MPa(3bar)
Maximum suction5m(16.4ft)
Flow rate range:  30-100L/min(7.9-26.4US.GPM)

Performance data:

ModelCaliberCapacityHeadMotor powerVoltage
(mm)(L/min)(m)       (W)(Phase)
WCB-30Cast iron2030303701ph/3ph
WCB-502050305501ph/3ph
WCB-752575307501ph/3ph
WCB-100251003011001ph/3ph
WCB-30PStainless steel2030303701ph/3ph
WCB-50P2050305501ph/3ph
WCB-75P2575307501ph/3ph

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Brief description of centrifugal pump on / off operation
(3) check whether the turning rotor is easy and flexible, check the pump body is clang or friction sound.(4) the protective cover is installed, and the shield contact.(5) clean the pump frame and do a good job of sanitation.(6) open the inlet valve, make the liquid full of pump body, open the vent valve, clean the air and close it. If the hot oil pump, it is not allowed to open the air valve exhaust, to prevent hot oil channeling spontaneous combustion, if there is a dedicated vent pipes and tanks, you can vent the pipe line air and cold oil.(7) the hot oil pump should be preheated slowly before starting. Especially in winter, the pump body and the pipe should be preheated at the same time, so that the temperature difference between the pump body and the conveying medium is below 50 centigrade.(8) the oil must be sufficiently dehydrated before being introduced into the oil pump.
Q:What does the impeller on the centrifugal pump mean by the first cutting?
There are 2 situations, first, for example, a XXXX-160 type pump head 32, flow 100, motor 15kW, according to the model we need to cut a become head 28, flow rate of 88, this time, in addition to cutting the impeller, the pump or the original pump motor, became 11kW this is, re designed a new model, namely XXXX-160A, but most structural components did not change. In the same way, we want to design a XXXX-160B that makes the head 24 and the flow rate 80, then we just need to cut the impeller again and match the smaller (7.5kW) motor (the motor bracket needs to be redesigned). In general, multiple cutting impellers are designed to expand and enrich the model. Second, the actual use, if you think the flow head is too large, but also can be cut to make it smaller to adapt to practical applications. But the 2 and 3 cuts you ask are the first.
Q:Concrete pump 125 pipe wall thickness
Concrete pump, also called concrete pump, consists of pump body and pipe. The utility model relates to a machine for continuously conveying concrete along a pipeline by utilizing pressure, which is mainly used for building, bridges and tunnels
Q:Is the diaphragm pump and the drain pump one?
Generally composed of actuators and valves.Pneumatic diaphragm pump, which has four kinds of materials: plastic, aluminum alloy, cast iron, stainless steel. The electric diaphragm pump has four kinds of materials: plastic, aluminum alloy, cast iron and stainless steel. Diaphragm pump diaphragm according to different liquid media, respectively, NBR, chloroprene rubber, fluorine rubber, PTFE, poly 46 ethylene to meet the needs. Placed in a variety of special occasions, for pumping various media.
Q:The working principle of magnetic pump
Control of cooling fluid flowThe pump is running, you must use a small amount of liquid in the magnetic separation between the rotor and the casing annulus area and sliding friction bearings for flushing cooling. The cooling liquid flow pump design flow is usually 2%-3%, the annular area between the magnetic rotor and sleeve of eddy current generated because of high heat. When the cooling and lubrication the liquid is not enough or poor flushing holes to plug, will result in permanent magnet medium temperature is higher than the operating temperature of the inner magnetic rotor gradually loses magnetism, the magnetic actuator failure. When the medium is water or water-based liquid, can make the annulus area temperature maintained at 3-5 DEG C; when the medium or hydrocarbon oil that can make the annulus area temperature maintained at 5-8 degrees.
Q:Suction stroke and lift of water pump
Lift pump lift pump can lift refers to the height, usually expressed in H, the unit is m. centrifugal pump lift to the impeller center line, divided by two parts. The vertical height from the pump impeller centerline to the water surface, the water pump to suck water up to the height, called water head, referred to as suction pump impeller; from the center line to the vertical height of the water tank, the water pump can put pressure on the height, called water pressure head, referred to as the pressure. The pump head = + suction head pressure water head should be pointed out that the nameplate marked head refers to the pump itself can produce lift, it is not with the pipe flow friction resistance caused by the loss of lift. In the selection of water pump, attention can not be ignored. Otherwise, will be pumping Sheung Shui.
Q:Piston filling and peristaltic pump filling which precision is high?
If the unit area is large, the accuracy of the plunger is certainly not high. The peristaltic pump is used by means of extrusion roller extrusion pump to promote the solution, this also depends on the unit cross section size, the same motor accuracy is very important.
Q:How to select hydraulic pump?
3. efficiencyVolume efficiency, for hydraulic pumps, is the ratio of actual flow to theoretical flow. A hydraulic motor is the ratio of its theoretical flow to its actual flow.Mechanical efficiency, for hydraulic pumps, refers to the ratio of theoretical torque to actual input torque. The actual output torque of the hydraulic motor is theoretical torque to overcome the torque after friction, so the mechanical efficiency is the ratio of the actual output torque to the theoretical torque.
Q:What kind of motor does the hydraulic pump need?
Calculation of actual oil pump power:First count the flow: Q=dn L / minD displacement / revN RPM / minThen calculate the actual power: N=QP/ (60K) kwQ flow L / minP MPa MPaK total efficiency (usually 0.85)I do not know what the landlord said, 2.5L is the displacement or flow at the end, the concept must not be confused
Q:The distance from the pump button to the ground
After confirming that the fire pump has started running, issue a command signal to the hydrant button to light the green answer light.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates