Product Description:

Specifications

1.for oil
2.cast iron&stainless steel
3.Size: 3/4"-2""
4.Self priming
5.MOQ 1 pc

2CY stainless steel hydraulic gear oil pump
1.for oil
2.cast iron, stainless steel
3.Size: 3/4"-2""
4.Self priming
5.ISO certificate
6.viscoity:5-1500cst
7.Temp: max 80C
Application
1.It applies to delivering non-corrosive lubricating-lil or equivalent liquid without solid particles. 2.Medium temperature bilow 80°C and with the viscosity of 5×10-6~1.5×10-3m2/S(5-1500cSt).
3.It can give performance as transferpump or booster pump in oil delivery system
4. It can be used as fuel pump for delivery,pressurization and injection in fuel supply system .
5. It can be also applied as hydraulic pump supplying hydraulic power in hydraulic system and in all industry fields as lubricating pump.
Structure Features
2CY series gear pumps are mainly composed of gears,axles,pump body ,pump cap,bearing sleeves and axle-end seals,etc.The nitriding-treated gears have the advantage of higher hardness and wear property,and they rotate with the axles inside the replaceable bearing sleeves.All of pump's parts can be lubricated by delivered medium when working.

Four bearing sleeves are installed suspended in pump body and can be automtically adjusted with facing gaps clearance complying with pressure change,therefore,it results in stable pump pressure,little discharge ,flow pulsation and higher volume efficiency .
Technical Data Sheet:

Model

Flow

(m3/h)

Pressure

(Mpa)

Vacuity

(Mpa)

Diameter

Power

(Kw)

2CY1.08/10

1.08

1.0

0.05

3/4”

0.75

2CY1.08/25

1.08

2.5

0.05

3/4”

1.5

2CY2.1/10

2.1

1.0

0.05

1”

1.5

2CY2.1/25

2.1

2.5

0.05

1”

3

2CY3/10

3

1.0

0.05

1”

2.2

2CY3/25

3

2.5

0.05

1”

4

2CY4.2/10

4.2

1.0

0.05

1 1/4”

3

2CY4.2/25

4.2

2.5

0.05

1 1/4”

5.5

2CY7.5/10

7.5

1.0

0.05

1 1/2”

4

2CY7.5/25

7.5

2.5

0.05

1 1/2”

7.5

2CY12/3.3

12

0.33

0.05

2”

5.5

2CY12/10

12

1.0

0.05

2”

7.5

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Metering pumps related matters
1., exports higher than imports, avoid siphonage2. the pump head and the injection valve require vertical installation3., the attached pipe can be tightened by hand, please do not use the tool; the thread does not use the raw meal belt4. the supply voltage is stable and grounded5. installation environment clean, spacious, well ventilated) 1) metering pump suction is not normal
Q:What are the main performance parameters of hydraulic pumps?
Displacement and flowDisplacement refers to the pump (or motor) every turn a week, by the size of the sealing chamber geometry variable discharge (or enter) the volume of liquid, commonly used unit is ml/r (ml / rev). Displacement can be changed as a variable pump (or variable motor), and the displacement can not be changed into a quantitative pump (or a quantitative motor).Actual flow is the amount of flow at the outlet (or inlet) when the pump (or motor) is operating. As the pump itself leaks, the actual flow is less than the theoretical flow. As the motor itself has an internal leakage, to achieve the specified speed, in order to compensate the leakage, the actual flow of input must be greater than the theoretical flow.
Q:Operating procedures for measuring pumps
start-up1. Adjust the stroke indication to zero by adjusting the nut or handle with the rotary stroke.2 open the outlet valve.3. Open the inlet valve, pump, exhaust from the high point, exhaust from the relief valve, the breather valve.4, point motor, check the operation of the pump.5. Start the motor.6, without pressure on the premise, every 15 minutes to improve the stroke 20%, if there is no pressure, do not substantially improve the stroke.Note: (1) whether the sound or vibration of the pump is abnormal (2), whether the stroke adjustment is automatic or not
Q:What is a feed pump?
Because under normal circumstances, the water pump suction port flow rate is low, can not meet the requirements of high pressure water injection pump. Therefore, the purpose of adding a feeding pump at the front of the water injection pump is to increase the flow rate of the inlet of the high-pressure water injection pump so as to meet its water supply requirements!
Q:Why should the pump be closed when the centrifugal pump is started?
On the other hand, the water on the pipe of the inlet pipe of the pump is stationary before the pump is opened, such as the sudden acceleration, and the water behind it can not keep up, which will cause the pressure of the inlet to drop suddenly and vaporize the water, and the centrifugal pump will be evacuated. (because of the centrifugal pump is rotating centrifugal force generated by the pump, leaf water and steam driven (gas) quality is very light, according to F= Ma, the centrifugal force is small, the pump can not be water sent).
Q:60 type concrete pump performance?
Specification for concrete cylinders:Bore * stroke mm 200 * 1650Hopper capacity L 800Feeding height mm 1400Motor model Y2-280M-4Power kw 90Rated voltage V 380Rated speed r/min 1480Soft starter withoutHydraulic system open-loop
Q:What are the characteristics of a vertical multistage centrifugal pump?
Vertical multi-stage centrifugal pump is cast iron, the advantage is that the price is cheap, the disadvantage is bulky and power consumption.
Q:What are the constant pressure pumps?
Chlorine booster pumpThe pressure range of chlorine booster pump is large, and different pump can be used to obtain different pressure area. The input air pressure is adjusted and the output pressure is adjusted accordingly. High pressure can be reached, gas 90Mpa. Wide range of flow, for all types of pumps only 0.1Kg pressure can work smoothly, at this time to obtain the minimum flow, adjust the intake volume can be obtained after a different flow. Easy to control, from simple manual control to fully automatic control, can meet the requirements. Automatic restart, regardless of what causes the pressure drop in the pressure loop, will automatically restart to supplement leakage pressure and maintain constant loop pressure. Safe operation, gas driven, no arc and spark can be used in dangerous situations.
Q:Does the reservoir water heater press the booster pump (high marks)?
The outlet water pressure of hot water is the same as that of cold water. The water heater is pushed by cold water to push out the hot water. (of heating). Installation location about 2 meters away from the ground, the impact of water pressure is not large, in rural areas, the installation position in more than two buildings will have an impact. In the city, the installation position is above four floor to affect the water pressure.
Q:Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
Four) release bolus dosage method can use automatic release and manual release two ways, the key is to alarm after the infusion must be stopped(five) any kind of pill dose release are not restricted to replace the pill. The total dose limit for in pipe blockage after pill agglomeration process will remove blocking accident, this time will be the rapid infusion of pill dose concentration into the patient's blood, if the total dose pill does not get test and limit, rapid infusion of this accident it may have unimaginable consequences.(six) supplies open type infusion pump overflow on the domestic market for pill characteristic parameters of consumables simply without testing and limitation. Therefore, the risk of accidental pill has become one of the residual risk of open type infusion pump supplies the most deadly.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range