Solar Power Storage Battery 12v 80ah Long Life Lead Acid Battery

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10 pc
Supply Capability:
1000 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications

12V 80AH battery for solar system and solar panel 
1)Germany material 
2)ce,ul,msds ,cgc,tlc 
3)export experience 15 years 

wholesale price!12V 80AH battery for solar system and solar panel         12v battery

1)Germany material
2)golden sun,msds ,cgc,tlc
3)export experience 15 years


  Battery Description:

Item 

    12V 80AH  gel battery 

Model NO. 

    LCPC80-12

Battery type

  GEL battery

Battery dimension

        331*176*214(mm) (L*W*H)

Nominal voltage

    12V

Nominal capacity

    80Ah

Net Weight 

    26.5kg

Cycle life 

   100%DOD  572times , 50%DOD   1485 times , 30%DOD   2406times 

Battery Case

    ABS case

Plate

    lead-antimony

Payment terms

    T/T(with 30% deposit),70% paid by the copy of BL

Loading port

   Shanghai

Main Market

 America,Africa, Mid-east,Asia ,South America, Europe 


 

Lead Acid 
  Battery Model

Nominal 
  Voltage 
  (V)

Nominal
  Capacity
  (AH)

Weight 
  (kg)

External Dimensions(mm)

Length

Width

Height

Total Height

LCPA 200-6

6

200

32

243

187.5

210

275

LCPA 24-12

12

24

7.5

176

166

126

125

LCPA 33-12

12

33

11

195

130

171

180

LCPA 38-12

12

38

12.8

196

165

170

180

LCPA 50-12

12

50

15

229

138

208

228

LCPA 65-12

12

65

22

350

166

174

174

LCPA 70-12

12

70

22.5

260

168

208

227

LCPA 80-12

12

80

26

331

176

214

214

LCPA 90-12

12

90

30

406

174

209

238

LCPA 100-12

12

100

31

406

174

209

238

LCPA 120-12

12

120

35.5

483

170

240

240

LCPA 150-12

12

150

47

532

207

214

240

LCPA 200-12

12

200

58

522

140

219

244

LCPA 250-12

12

250

67

520

269

219

245

 

 

Batteru Features :

 

1. Maintenance-Free Operation 
Absorbent Glass Mat (AGM) technology ensures efficient gas recombination up to 99% and freedom from electrolyte maintenance. During the expected float service life of Prostar batteries, no need to check the specific gravity of the electrolyte or add water.
2. Good Discharging Ability
Tight assembly technology ensures an excellent high-rate discharge performance.
3. Long Service Life
A unique corrosion-resistant grid alloy ensures Prostar batteries have long service life.
4. Low Self Discharge
Using high purity raw materials ensures Prostar batteries have less self-discharge.
5. Environmental & Non-polluting
Gas Recombination technology ensures the battery high seal reacting rate, which can prevent the acid fog from separating out.
6. Safe & Reliable
Efficient venting system automatically release excess gas when the pressure rises above the normal level & reseals the valves when it returns to the normal rate, which can protect the battery from bursting.


Applied Scope :

 
1. Communication Systems: Switch, Microwave Stations, Mobile Base Stations, Data   Centers, Radio and Broadcasting Stations
2. Motivity Field: Robots, Electric Toys, Electric Tools & Portable Vacuum Cleaners
3. Solar & Wind Power Generation Systems
4. Signal System & Emergency Lighting Systems
5. EPS & UPS Systems


Photos of Factory:

Solar Power Storage Battery 12v 80ah Long Life Lead Acid Battery

Solar Power Storage Battery 12v 80ah Long Life Lead Acid Battery

Solar Power Storage Battery 12v 80ah Long Life Lead Acid Battery

Solar Power Storage Battery 12v 80ah Long Life Lead Acid Battery


FAQ of Products:


Q1 : What is you advantages

A1:

a).We are professional ups manufacturer for more than ten years and we have these staffs with rich

     production and R&D 

b) Excellent workers and skilled engineers 

c).Our aims are to provide every customer high quality, reasonable price and excellent 

    service.

d)we can guarantee to send the goods on time. And also accept any transportation ways that

    you require 

 

Q2 : How do you control the production quality

A2:

a) For materials, we have IQC departments and the IQC testing follow MIL-STD-105E standard

b) in production have 4 times function testing

c) all of our products with 100% burn-in testing

d) 100% QC testing before delivery

 

Q3 : Do you accept OEM/ODM?

A3 : ODM&OEM are warmly welcomed !!!

 

 

Q4 : what’s your payment?

A4:

a) We can accept payment terms of T/T, Western Union, PayPal

 

Samples and trial order accept PayPal ,T/T & Western Union. normal order accept T/T &Western Union 

 

b) 30% ADVANCE DEPOSIT after buyer's confirmed payment, the balance should be paid before shipping when goods are ready.




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How does the battery increase the voltage?
With the same battery pack in series; if the required current is relatively small, you can use DC-DC module.
Q:What are the technical parameters of the battery?
Usually the capacity of the power supply is expressed by kV · A or kW. However, as a power supply VRLA battery, the use of security (A · h) that its capacity is more accurate.
Q:80ah how much battery storage capacity?
0AH storage is 80AH ah If the actual storage capacity will have to see the brand. I have seen 100AH only 24 pound. This is not even 60AH.
Q:Maintenance-free battery how to detect it?
Keep the battery surface clean. If the discovery of solid oxide on the pole, it should be timely with hot water pouring, to be removed, so as not to affect the pole and the terminal between the continuity. After cleaning up, wipe the battery surface, in the pole and the terminal cast on the butter to ensure that the pole is not oxidized.
Q:How to repair the battery?
Maintain the battery before, first of all to clean up the battery appearance of the dust, remove the terminal above the stain and corrosion.
Q:What is the meaning of the battery above 12v65Ah?
12V represents the rated voltage. 65Ah indicates that the battery capacity (ie 1 ampere current can be used for 65 hours).
Q:Lead-acid battery how to maintain?
After passing the test, cover the exhaust cutting, pay attention to restore the filler, cover the battery cover, if the cover is glued, then glue bonding.
Q:How is the capacity of the battery defined?
100AH capacity of the battery, fully charged after the 100A current discharge can be an hour to put the power finished. 50A current is 2 hours put away! 20A is 5 hours! Of course this is the theoretical value, in fact it is impossible to have a constant current discharge.
Q:What are the hazards of battery over discharge?
Crystalline conductivity is poor, and bulky, will clog the pores of the battery plate, affecting the battery electrolyte penetration and exchange, but also further increase the battery resistance, a long time will prevent the battery power and chemical energy Of the reversible conversion, resulting in poor recovery of the battery charge, the battery was seriously damaged, or even unable to repair until scrapped.
Q:What is a maintenanceable battery?
This is relative to a maintenance-free battery. Maintenance of the battery needs to be supplemented with electrolyte to ensure work, while maintenance-free is not required.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range