Solar Battery REX Series for Solar and Wind Power REX-300

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1000 unit
Supply Capability:
5000000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Solar Battery REX Series Introduction

REX battery  is designed for Renewable Energy Sources such as  Solar and Wind Power. REX protects  our environment using Green Technology and  benefits the World's Urban  and Rural Population by Generating  Power Economically from a Clean Source  of Energy.

REX is a product developed  by our R&D with  an " eXtra" in Performance  and Life Span.
The REX series batteries are ensured the quality with  QA  system according to the ISO9001&ISO14001 standard.

 

Solar Battery REX Series for Solar and Wind Power REX-300

Solar Battery REX Series for Solar and Wind Power REX-300

Solar Battery REX Series for Solar and Wind Power REX-300

Solar Battery REX Series Features and Benefits

  • Long life design for both  cyclic and float applications

  • Superb security and  reliability

  • Robust design inside and out

  • Excellent deep discharge  recovery fast recharge performance

  • Extra long back-up times

  • More cost effective than  nearest equivalent


Type:

  REX-300

Voltage:

  2V

Nominal Capacity:

  300Ah(C10)  300Ah(10 hours rate:)

Length:

  227mm

Width:

  133mm

Height:

  291mm

Height   with termial:

  303mm

Weight:

  24.5Kg

Solar Battery REX Series Compliant  Standards

  • IEC60896-21/22

  • IEC61427

  • BS6290 part 4

  • Telcordia SR4228

  • Eurobat guide

  • UL

  • Manufactured under system  ISO9001(TUV) and ISO14001

Solar Battery REX Series  Battery  Installation Compliant with

  • EN 50272-2 or local  equivalents

Solar Battery REX Series Main  Applications

  • Renewable energy source such  as solar and wind power

  • Telecom exchange and transmission  system

  • Mobile communication system

  • Power plant and power  transformer system

  • Navigation aid signaling  system

  • Radio and broadcasting  station

  • Emergency lighting system

  • Other standby, cyclic system

Solar Battery REX Series Installation  and Operation

  • Recommended float charge voltage  2.27V per cell at 25oC
     compensation in function of temperature -3mV/oC/cell

  • Cycle and equalize charge  voltage: 2.35V per cell at 25oC
     compensation in function of temperature -5mV/oC/cell

  • CC-CV charge current  unlimited, otherwise 150A  max. if T>25oC

  • Preferred operating  temperature range 15oC to 25oC(68oF to 77oF)

  • Maximum operating  temperature range -40oC to 50oC(-40oF to 122oF)

  • A separate battery room is  not necessary

  • Reduced maintenance no water  addition required.

  • Design float life: 20 years at 25oC (77oF)

Solar Battery REX Series Construction

  • Positive plate --- Reinforced grids in a corrosion-resistant pure  lead, high tin, low calcium alloy

  • Negative plate --- Lead-calcium alloy grid

  • Separator ---  High  density microporous glass mat with low electrical resistance

  • Container & lid --- High strength ABS(HB). Optional flame retardant F V-0 and halogen-free versions available

  • Electrolyte --- Sulphuric acid with a density of 1.28g/ml  absorbed in AGM

  • Terminal design --- Patented leak resistant seal configuration with  brass insert

  • Safety valve --- Calibrated opening pressure , the valve  equipped with flame arrestors for  increased operational safety and service life.

 FAQ

How long a battery can last?

The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.

Do batteries self-discharge when not in use?

All batteries, regardless of their chemistry, self-discharge. The rate of self-discharge depends both on the type of battery and the storage temperature the batteries are exposed to. However, for a good estimate, Narada batteries self-discharge approximately 4% per week at 80ĄăF.

What is battery cycle life?

One cycle of a battery is a discharge from full charge to full discharge and a return to full charge again. The total number of cycles a battery can perform before failure is called its Cycle Life. Moat battery manufacturers will not discus the Cycle Life of their product. Many advertised Deep Cycle batteries have not been tested, or, which is the case with cranking batteries, were never designed for long Cycle Life .

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to repair the battery?
Pry open the adhesive or heat-sealed battery cover, reveal the maintenance-free battery rubber exhaust valve, carefully remove the exhaust valve, save, observe the battery internal situation. Add 0.1% to 0.5% of the electrolyte to the battery, just to the battery above the flow of electrolyte. At the same time, check whether the black impurities, if there are obvious black turbid impurities, indicating that the battery plate has been significantly softened, the possibility of battery repair is relatively small. If there is no black muddy impurities, need to wait 4 hours later, the water fully into the battery. If it is only because the deactivation time is long and cause the battery capacity to decline, do not need to carry out this step operation, should go directly to step 3 pre-charge.
Q:What are the advantages of maintenance-free batteries?
Maintenance-free battery because of its normal charging voltage, the electrolyte only produce a small amount of gas, so throughout the use of the need for the addition of distilled water, in the normal charging system, do not need to remove the charge from the removal. But in the maintenance of the proportion of its electrolyte should be checked.
Q:What is the difference between a maintenance-free battery and a conventional battery?
Different materials will produce a different phenomenon: the traditional battery in the course of the use of the phenomenon of liquid reduction occurs, because the antimony on the grid will pollute the sponge on the negative plate of pure lead, weakened after the full charge of the battery Electromotive force, resulting in excessive decomposition of water, a large number of oxygen and hydrogen, respectively, from the positive and negative plates to escape, so that the electrolyte reduced. With calcium instead of antimony, you can change the fully charged battery back electromotive force, reduce the overcharge current, liquid gasification rate decreases, thereby reducing the loss of electrolyte.
Q:Battery 200ah / 104 what does that mean?
This should be refers to 2V200AH battery 104, power with the 220V. Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.
Q:80ah how much battery storage capacity?
Is 80AH. Understood to discharge at 80 amps for about 1 hour (but not to say that after 1 hour is finished, there is still electricity). In theory, this is your battery power.
Q:How does the battery increase the voltage?
Chemical energy can be converted into electrical energy device called chemical battery, generally referred to as the battery. After discharge, the internal active material can be regenerated by charging - the electrical energy stored as chemical energy; chemical energy can be converted to electrical energy again when the discharge is required. This type of battery is called a battery (Storage Battery), also known as secondary battery.
Q:How is the capacity of the battery defined?
100AH capacity of the battery, fully charged after the 100A current discharge can be an hour to put the power finished. 50A current is 2 hours put away! 20A is 5 hours! Of course this is the theoretical value, in fact it is impossible to have a constant current discharge.
Q:What kind of battery is divided into?
Ordinary battery: ordinary battery plate is composed of lead and lead oxide, the electrolyte is sulfuric acid aqueous solution. Its main advantage is the voltage stability, the price is cheap.
Q:What is a maintenanceable battery?
This is relative to a maintenance-free battery. Maintenance of the battery needs to be supplemented with electrolyte to ensure work, while maintenance-free is not required.
Q:The role of the battery?
It filled with lead plate filled with sponge lead as a negative electrode, filled with lead dioxide lead dioxide as a positive electrode, and with 22 to 28% dilute sulfuric acid as electrolyte. In the charge, the electrical energy into chemical energy, the discharge of chemical energy and into electrical energy.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range