Solar aluminum alloy frame 1640*992*40*35mm

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

UseEdit

Fixed,sealedsolar modules,strongenhancementshelpprolong life, easy to transportand install.

Advantagesedit

1quality.Complete quality controlsystemto ensure thequality of the product.2productionis superior.Specialized productionand stable quality,able toprovide customers withlarge quantitiesof varioustypes ofaluminumborder.3well-equipped.FromJapan,the main productionequipmentimported from Germany,mold well,accuracy up to0.02mm.

Solarphotovoltaic applicationsinthe field offrameadvantages:

Ananti-corrosion,oxidation resistanceand strong;

2strength andsolid and strong;

Strongthreetensileproperties;

4elastic modulus, rigidity,metal fatiguevalue is high;

5transport, easy to install,evenscratchedthe surfaceoxidationdoes not produce, does not affectperformance;

Sixdifferentselectionthrougheasyto adapt tovarious environments;

7service life of30-50 years.

Sizeeditor
1) 35 * 35mm,suitable for80-180wattsolar modules;

2) 40 * 35mm,suitable for200 - 300wattsolar modules;

3) 50 * 35mm,suitable for160-220wattsolar modules;

4)Many othercustomsizes,such as, 40 * 28mm, 40 * 30mm, 40 * 35mm, 42 * 35mm, 45 * 35mm, 46 * 30mm, 46 * 35mm 46 * 40mm, 46 * 48mm, 46 * 50mm, 46* 60mm, 60 * 35mm,and the like.

Common specificationsare:

1956 * 992 * 50mm

1650 * 992 * 45mm

1640 * 992 * 45mm

1580 * 808 * 40mm

1576 * 808 * 40mm

1482 * 670 * 40mm


Otherlengthscan beproducedaccording to customer requirementsframe

Two types ofediting

1)90Angle

2)45angle



5Surface Treatmentedit



1)anodized(silver,black, silver,····)(thicknessAA10, AA15, AA18, AA20)
2)electrophoresis(white,black)(thickness≥15, ≥16, ≥18, ≥20)

3)powder coating, PVDF,sandblasting, etc.



6 Standardeditor

GB / T5237 - 2004, Q / 320 281PDW01-2008



7specificationeditor

Specificsizescan be designedaccording to customer demand.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What are the hidden dangers of solar PV systems? It is best to classify, such as stents, inverters.
Antistatic floor of the stent system is worth mentioning is "easy to pave the way." "Easy to pave the" anti-static floor bracket system is a patented technology, but also the only use of aluminum alloy stent system to do the system, good stability, high load, integrity, pavement after the anti-static floor is very smooth ,
Q:What are the characteristics of the hydraulic support hydraulic system?
The system of the solenoid valve, but also consider the system of the media, because it is not flammable; second, in these places must ensure that the equipment in the absence of power in the case will not happen, such as hydraulic cylinder return, hydraulic motor
Q:Fire engineering, piping, valves, stent installation of what specific requirements
Design drawings and other technical documents complete, and reported by the owners and supervision and approval. Construction plan has been approved, and made to the team at the end. Temporary facilities and water supply, power supply to meet the normal construction requirements. Related equipment has been fitted and into the scene, with construction conditions.
Q:What are the benefits of finished stents?
U prefabricated welded steel groove will inevitably lead to error errors, affecting the quality of the project, reduce the safety of the project, causing hidden dangers, adversely affected by the duration.
Q:Easy to pave the anti-static floor bracket system?
The patent is made of a specially designed T-shaped aluminum and a dedicated grooved binaural leg to form a straight line, and then a plurality of straight lines are formed in a very flat plane, Between the material, the composition of a width of 600mm is very flat track,
Q:Fire spray installation in the anti-swing stent approach?
4 water branch on each pipe section, adjacent to the nozzle between the pipe set of hanger should not be less than one, the hanger spacing should not be greater than 3.6m.
Q:Is the template and stent two or one?
Material staff, that is, the contractor to see the words in accordance with the quota on it. The template is the contact area, the stent is the building area.
Q:What is the difference between a shock support and a conventional stent?
he lack of horizontal seismic support structure; 2, seismic support hanger mainly bear the horizontal load of the pipeline
Q:Specification for installation of fire pipe support
The height and spacing of the fire pipe support shall be in accordance with the requirements of the design and construction specifications.
Q:How to build an effective teaching stent
analysis of teaching problems and needs, design solutions to teaching problems and strategies to implement the design, evaluation, and constantly improve the design of a systematic process.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range