Quick Details

  • Place of Origin:Henan, China (Mainland)

  • Model Number:WQS15-40

  • Theory:Centrifugal Pump

  • Structure:Single-stage Pump

  • Usage:Water

  • Power:Electric

  • Standard or Nonstandard:Standard

  • Fuel:Electric

  • Pressure:High Pressure

  • Application:Sewage

  • Material:Cast Iron / Stainless Steel

  • Color:Yellow-orange

  • Flow:15m3/h

  • Head:40m

  • Stage:Single

  • Power:5.5 KW

  • Drive:2900rpm Motor

  • OEM:Accept

Packaging & Delivery

Packaging Details:wooden box packing
Delivery Detail:5-7days after payment confirmation or as customers' requirement

Specifications

small sewage pump for home use
1.28 years production experience
2.Reliable quality
3.no-leakage
4.wide runner

small sewage pump for home use

Operation parameters

(1).  Flow range :5~300 m3/h

(2).  Lift range : 5~240m

(3).  Diameter range: φ25~φ200mm

Product overview

WQ sewage submersible pump is non-clogging sewage pump developed on the basis of the introduction of foreign advanced technology, now is the most advanced internal sewage systems. Features: notable energy saving effect, non-clogging , anti-winding, strong particles passing ability, automatic installation, automatic prosecution, etc.

WQ series submersible sewage pump is power irrigation equipment united by the motor and the pump, especially the swirling impeller and double-channel impeller matched with spiral type centrifugal pump body, which have extremely strong drainage capacity; The motor part adopts mechanical seals of hard corrosion double end face ceramic, which have very good effect of seepage prevention, its protection level is IP58 and designed insulation class is grade E (75 K), motor running more safe, reliable, and long service life, convenient installation.

 

Product features

(1). Compact structure, easy to move ,easy installation

(2). Specially adopting cyclone type and double flow type impeller ( high lift pump adopts centrifugal type), strong pollution discharge capacity

(3). The motor adopt hard corrosion-resistant single and double end face ceramic seal , good anti leakage effect, the motor running more safe and reliable;

 (4). Adopting cooling sleeve type WQS water filling pump makes they can run above the liquid level for short time and drain the ground liquid.

Product usages

(1).  Enterprise wastewater discharge

(2).  Drainage system of city sewage treatment plant

(3).  Drainage station of subway, underground chamber, air defense system

(4).  Sewage drainage of hospitals ,hotels, high-rise buildings

(5).  Sewage drainage station of residential district

(6).  Thin mud drainage of municipal works and construction site

(7).  Water supply equipment of water plant

(8).  Sewage drainage of farm and agriculture irrigation of village

(9).  Mining exploration and water treatment equipment supporting

(10). Replacing the shoulder carries to deliver river mud

Using condition

(1).  Based on the impeller center, the underwater depth that the pump was placed shall not exceed 5 m

(2).  Temperature of the transport medium not more than 40 centidegree

(3).  Transported medium's PH value for 4 ~ 10, and pump shall not carry high corrosive liquid

(4).  The transfer medium's solid volume ratio under 20%

(5).  The movement viscosity of transport medium for 7×10-7~23×10-6m²/s

(6).  The biggest density of transfer medium for 1200 kg/m ³

(7).  WQ submersible pump, motor must be dived into the underwater to operate

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Water pump maximum flow and standard flow?
Centrifugal pump, flow and head is an inverse relationship between the maximum flow, you said, lift the corresponding conveying pump is relatively low, the standard flow, the rated flow is designed and run in standard flow, pump efficiency is the highest, if more than the standard flow operation possible lead pump overcurrent heating, and a series of cavitation phenomena
Q:How can I pump the motor insulation?
A submersible pump to shake the insulation, water pump distance more than 20 meters away from the cable distribution box is fixed, at this time to shake the insulation in the distance distribution box can only shake, disconnect the power cable is connected with the shake table, the ground end is connected with the electric box so that the pump shell shake shake, also must be reliable grounding to shake to now, the pump shell grounding not only in the water, it must be a wire connected with a shell or a wire will be immersed in water, this is right insulating shake,
Q:What's the difference between a cold water pump and a hot water pump?
Cold water pump is generally packing seal, hot water pump is generally mechanical seal. If the cold water pump is used to transport hot water, the common trouble is that the shaft seal is easy to leak and the water pump is easy to damage. Generally in the design of building water supply and drainage, cold water pump and hot water pump can be selected according to the cold and hot water. Water supply and drainage design manual (common equipment) and pump manufacturers Water Pump samples can be found.
Q:What is the influence of the speed of the pump motor on the pump?
The question is very general,In general, high speed motors are used in 2 stages, 2900 revolutions per secondLow speed motor with 4 stage, 1450 revolutions per secondYou can probably generalize to thisWith the flow, head, run the pump speed type low noise will be reduced but the service life of the motor (relatively high speed), but the speed of price ratio low speed expensive (motor level 4 level 2 line than for more than copper)For example, it seems that the reason why turtles live longer is that their heart rate is slow.
Q:Water pump is not Sheung reason
The problem you are experiencing is stressThe above answer is only considered in the case of water absorptionJust imagine, two pumps are normal work, the same suction pipe, how can there be dissatisfaction with water or vacuum state?.According to my experience analysisYour system is three sets of parallel, lift and flow should be the same, if not the same, not in this discussion, the topic should be set up.Lift is the same, that is, in two or three units at the same time, the resulting system pressurization is the same, and water will increaseBut now your traffic is increasing at two units, but it will not increase at threeYou have selected pipeline system design, in the design of head flow under single condition is constant, if the increase in open water pump, the pressure is constant, increasing water content, according to the continuity equation Q = A X V, then the flow velocity in the tube will increase;But when the third pumps, 2Q becomes 3Q, normally velocity should be larger, but the Darcy formula shows that the velocity increases, extension resistance and local resistance will be increased, and the double square, so you can open third pumps for reasoning, when the resistance effect caused by the pipeline the increase of water flow in the pipeline can not be reused, the general formula of constant current, now the whole pipeline in turbulent stateThat is, third pumps to do the work in the water and pipe wall friction in the loss, and actually did not play a role in water supplyThe solution is to increase the flow rate by increasing the water supply pipeline
Q:Why is the minimum liquid temperature allowed at 2 DEG C instead of 0?
It freezes at 0 degrees, and the pump runs and gets stuck.
Q:What motor with Grundfos pumps
Our company is used in the original metering pump Grundfos, with the SIEMENS motor is a special motor, designed with Grundfos pumps use.
Q:Why is the water pump smaller than the pipe diameter?
The size is only a matter of convenience or experience, and a small number of tubes are already available. As long as you can pick it up, you can use it.The so-called thick pipe to reduce resistance is a certain relationship. But it shouldn't be your decision to choose the big one. Then why don't you choose the big three? Four or the thicker ones?! @! The resistance will be smaller!!!!
Q:Pump performance parameters have three sets of data, how to understand the flow, lift, flow speed
1, the head is composed of a water pump design decisions, such as motor speed, power, blade shape; the flow is determined by the motor power and lift, the same power lift higher flux is small; velocity determined by flow and pipe section with a pump pipeline section greater velocity.2, the pump is to transport liquid or liquid pressurization machinery. It will be the prime mover of the mechanical energy or other external energy transfer to the liquid, the liquid energy increase, mainly used to transport liquids including water, oil, alkali liquid, emulsion, suspension emulsion and liquid metal, but also transport liquid, gas mixtures and liquids containing suspended solids. Pump performance of technical parameters are flow, suction, lift, shaft power, water power, efficiency, etc.; according to the different principles of work can be divided into volume pumps, vane pumps and other types. Displacement pump is to use its studio volume changes to transfer energy; vane pump is to use the rotating blade and water interaction to transfer energy, there are centrifugal pumps, axial flow pumps and mixed flow pumps and other types.
Q:2 pumps parallel, lift the same, pump head is not stacked?
2 pumps parallel, lift the same, pump head is not stacked?;Answer: the head can not be superimposed, that is, a lift and a pump, but the pumping speed (flow) is two times a taiwan.2 pumps in series, the same flow, pump head is not stacked?.Answer: the head can be superimposed, that is, the pump head is two times as much as a pump, but the pump speed is the same as that of a pump.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range