Slush Pump

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT or L/C
Min Order Qty:
1 Set set
Supply Capability:
1000 Sets Per Year set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Typical applications include pumping water for aquaponics or hydroponics applications and conducting garden drip irrigation.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:About how to calculate the pump installation height?
Best to find water pump manufacturers, their own bad count. Sometimes is not necessarily correct, which is related to some parameters of the pump itself, with bad cavitation
Q:Fire pump room is required to set up water pump control room?
What is the concept of fire pump control room? If there is a control room host automatic alarm automatic fire alarm system of words (through the pump distribution box can also control) can control the fire pump, if there is no distribution box automatic alarm system you can through the pump room control
Q:What's the submersible pump?
Centrifugal pump, a general motor and pump body is one, you can pump the whole pump into the water
Q:Why does the GB/T3216 specify the pump performance tolerance as positive and negative?
Tolerance coefficient is due in the manufacturing process, will, so each pump products are possible shapes and sizes do not conform to the pattern of the situation, and ensure the test results in the value (operating point) when compared, should be allowed to have a certain tolerance. It should be noted that these tolerances are only relevant to the actual pump and do not involve test conditions and measurement uncertainties.If the pump at a certain working point (the same lift) standard (Design) flow of 20m3/h, the actual flow of 22m3/h, indicating that the pump in the design process has unreasonable place, resulting in waste of power. Deviations from the manufacturing process usually have no positive deviation.
Q:Pump adapter joint net outside tube, what is the principle?
First, the working principle:Fire pump adapter is connected with the public security fire department fire engine or motor fire pump fire water transport through the fire pump adapter interface fire water supply pipeline to the buildings, the fire hydrant indoor get sufficient pressure to solve the problem of water shortage and other difficulties or because of fire water supply pipeline inside the building due to low water pressure caused by the fire fighting for high-rise building, indoor use and normal operation of fire pumps and intermittent water supply situation in. The installation types include floor type, underground type and wall type.A brief introduction to the two, pump adapter:When a fire occurs, the fire engine pump can quickly and conveniently through the interface and building the adapter in the fire fighting equipment is connected, and the water pressure, so the indoor fire equipment pressure with sufficient water to extinguish, different floors of fire, effectively solves the problem of building fires, fire fighting because of difficulties or indoor fire fighting equipment due to lack of adequate water pressure to the fire.
Q:4--6 inch deep well pump head? How much per hour out of water?.
Deep well pump head is based on how much the impeller, impeller 200QJ section is 11 meters lift, 250QJ is about 17 meters, 300 meters high lift, 4 inch flow in 80 to 100 tons per hour, 6 inch flow in 150 to 200 tons per hour
Q:Why is the minimum liquid temperature allowed at 2 DEG C instead of 0?
It freezes at 0 degrees, and the pump runs and gets stuck.
Q:Two pumps automatically switch start control circuit,
The puddle is full, the float switch is closed, and the relay J1 works to drive the first motor. The J1's work makes the intermediate relay 'J' work and locks itself, preparing for the work of the second machines. The water level is lowered to the required minimum position, the ball is broken, the motor is stopped and the motor is stopped. When the water level rose to the highest position again, the floating ball closed again, the relay J2 and self-locking relay J2 to drive second motors, instant intermediate relay are opened, when the water level again be reduced to the lowest position, float off, the motor stops working, stop by working in front of the intermediate relay. The whole circuit back to the original state. So that the two motors work alternately.It should be noted that the circuit diagram for simple to understand, only painted the control circuit, there is no main circuit, there is no missing phase, leakage, over-current and other protection, the actual installation needs to be installed. There is the role of time relay is to ensure that the relay J2 normal work, the intermediate relay is disconnected, so that the motor 2 does not occur wrong action, time relay can be set to a few seconds, or even less than a second. Intermediate relay can also be controlled by time relay, and its time is also set very small, so as to avoid J2 short time possible power supply.
Q:The problem of single phase pumps
Is your starting capacitor pump is broken. Because you pump it is a single asynchronous motor..... Single-phase asynchronous motor by capacitive phase shifting function, the single-phase alternating current isolated from another 90 degree phase alternating current. The two alternating current into two groups or four groups of motor winding, forming a rotating magnetic field inside the motor rotating magnetic field induced current in the rotor, the induced current magnetic field and rotating magnetic field in the opposite direction, by rotating magnetic field push pull into the rotating state, because the rotor must be cutting magnetic lines to produce induction current, so the rotor speed must be lower than the rotating magnetic induction motor speed, so thatSo if the starting capacitor is broken, then your pump will start difficult,
Q:Fully automatic self-priming pump
Yes, design according to your different working conditions. For example, water pressure pump is pressure control, water pressure is low will automatically start, the pressure automatically shut down.

1. Manufacturer Overview

Location Jiangsu,China
Year Established 1996
Annual Output Value Below US$1 Million
Main Markets
Company Certifications ISO14002;ISO9001;UKAS

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shanghai port;
Export Percentage 71% - 80%
No.of Employees in Trade Department 10 People
Language Spoken: English, Chinese
b)Factory Information  
Factory Size: Above 180,000 square meters
No. of Production Lines Above 10
Contract Manufacturing OEM Service Offered;Design Service Offered
Product Price Range High and/or Average