Slurry Anti-Abrasive Electric Driven Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.Specifications of Slurry Anti-Abrasive Electric Driven Pump• Horizontal centrifugal diesel slurry pump
• Flow-passage parts: cast iron, high chrome alloy lined or elastomer rubber lined
• Easy maintenance,High efficiency
• OEM/ODM
• Good quality and service
2.Main features of Slurry Anti-Abrasive Electric Driven Pump
transporting slurries with high ablation or high density.
Widely used for mining.
Widely used for power station
Widely used for chemical industry.
coal mine.
3.Specification of Slurry Anti-Abrasive Electric Driven Pump
Item | Slurry Belt Driven Pump |
Sludge Pump | High Quality Cast Iron Horizontal Sludge Pump |
Model | CMAH |
Material | Cast iron,Metal |
Mode | Horizontal |
Color | Blue |
Drive | Belt |
Seal | Soft packing seal |
Theory | Centrifugal Pump |
Structure | Single-stage Pump |
Usage | Slurry |
Power | Electric |
Standard or Nonstandard | Standard |
Fuel | Diesel |
Pressure | High Pressure |
Application | Industrial,mining, coal mine, power station |
Outlet Diameter | 40-350mm |
Capacity | 10.8-5400m3/h |
Head | 3-118m |
Rotation Speed | 300-3800r/min |
Power | 15-1200kW |
Certificate | ISO9001 |
Feature | High efficiency,Easy maintenance |
4.FAQ
① What is your product range?
Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage
pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe
water pump, boiler water pump, etc.
② Are you a manufacturer?
Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.
③ What information should I let you know if I want to get a quotation?
Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also
provide the pump model you are using now, price will be calculated as per the pump model, if not, we will recommend relevant product for reference.
- Q:Troubleshooting of diaphragm pump
- The ratio of flow to water weight at a specific weight of --68F. 68F water has a specific gravity of 1Static suction head - the vertical distance from the liquid level to the central line of the pump. The pump shall be above the level of the liquid.Vapor pressure the pressure of all the steam on the free surface of the liquid. In any pump operating system, the operating pressure shall not be lower than the vapor pressure, otherwise the steam will be partially or completely cut off into the pump fluid. Viscosity - because of the presence of friction in the fluid, the property of viscosity gives the fluid resistance to flow.Water hammer action -Water hammer is a sudden power failure, or in the valve closed too fast, due to pressure, flow of inertia, produce water shock waves, like hammer hammer, so called water hammer. The force produced by the flow of water shock waves can sometimes be very large, thereby damaging the valves and pumps. Water hammer effect refers to the inside of the water pipe, the pipe wall is smooth, flow freely. When the opening of the valve suddenly closes, the flow of water to the valve and the tube wall, mainly the valve, will produce a pressure. As the pipe wall is smooth, the subsequent water flow in the role of inertia, the fastest reach the maximum and damage, which is the water conservancy "water hammer effect", that is, "positive water hammer.". This factor should be taken into consideration in the construction of water conservancy pipelines. On the contrary, the valve closed in a sudden opening, it will produce water hammer, called negative water hammer, but also a certain destructive power, but not the former big.. Causes and treatment methods of common failures of diaphragm pumps:
- Q:Does the reservoir water heater press the booster pump (high marks)?
- 60 liters of water storage should be able to drive two bathrooms at the same time bath! Water storage water heater generally does not need booster pump, as long as there is a little pressure, the water heater is filled with water, as long as the tap water can do. You can turn off the hot water valve and see only the amount of water in the cold water. If hot water is much smaller than cold water, it is the reason for the heater. Can you check the water mixer is normal, the one-way valve is installed in reverse.
- Q:Why does the centrifugal pump close the pressure to start?
- Therefore, the operation rules of multistage centrifugal pumps require that the inlet valve be opened before opening, and the outlet valve is closed. However, the export valve closed time can not be too long, because at this time the medium in the pump cycle, the medium temperature gradually increased, easy to cause mechanical seals, due to lack of lubrication friction and wear or damage.
- Q:What is the series of pumps? What is the difference between a unipolar and a multilevel? What is the meaning of each "first class"?
- Each impeller is of the first stage. (two impellers share only one level, and exit is only level one)
- Q:What are the characteristics of a pipe shield pump?
- Two, reverse circulation type of shielding pump, its bearings, lubrication, cooling and motor cooling fluid flow direction and the basic type is the opposite. The main characteristic of reverse circulation pump is that it is not easy to generate cavitation. It is suitable for conveying liquid which is easy to vaporize. Sometimes it is also called "easy to vaporize" type. Three, high temperature medium temperature of up to 450 degrees. The cooling water jacket is usually added outside the shielding motor, and a cooling sleeve is added to the outer circulation pipe to cool the high temperature circulating liquid to reduce the temperature of the motor and the bearing. In the case of less power, some manufacturers do not use cooling liquid, but the outside of the motor is equipped with fins and the special winding to adapt to the working conditions, the use of temperature generally can not exceed 400 degrees.
- Q:What are the internal losses in centrifugal pumps? How did they come about?
- Volume loss: loss due to leakage;3. mechanical loss
- Q:Harm of air pump and pump
- Minimum starting current when centrifugal pump of such a small impact on the grid but long closed operation will make the liquid in the pump to the pump overheating temperature is too high will lead to the problem of the seal to a certain temperature will cause deterioration of oil bearing bearing caused by excessive wear and even bite dead
- Q:There are 6 pumps, two indoor fire hydrant pumps, two spray pumps, two outdoor pumps, three units, one master and one spare control cabinet. From the control room to the control cabinet, is there only 3 lines or 9 lines?... How do I get it? Where does the hydrant line come from?
- Indoor fire hydrant pump in addition to remote direct Kai, there are modules to start function, that is, on the cabinet to add control module, bus linkage pump, but also fire hydrant button, direct pumping function, a total of three functions.Outdoor fire hydrant pump in addition to remote direct Kai, but also an electric contact pressure meter detection system, water pressure from the pump and high pressure pump stop function.
- Q:What is the liquid pump? What are their categories? What are their strengths and weaknesses?
- The pump is constructed by connecting large diameter gas piston with small diameter hydraulic piston. The two piston area ratio produces a pressure ratio, and the maximum output pressure can be calculated by the pressure ratio. High pressure ratio produces high outlet pressure. You can set the outlet pressure through a simple gas pressure reducing valve. Pressure ratio * gas drive pressure = output pressure.
- Q:How to distinguish the flow and displacement in the hydraulic pump? What's the difference between the two?
- For example, once you sprinkle water from the tank to the ground, one shot of water is 1000 milliliters, which is equivalent to displacement, once (pump turn) 1000 ml.,
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Slurry Anti-Abrasive Electric Driven Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords