Single-side Climbing Bracket SCB180:

With CNBM SCB 180 climbing systems, the loads from the fresh concrete pressure are

transferred through the brackets by means of V-strongbacks and compression braces into the

scaffold anchors.

Typical applications for the SCB 180 are dams, locks, cooling towers, pier heads, tunnels, and

bank vaults.

The formwork is simply tilted backwards when striking takes place. The 1.80 m wide bracket

requires only a minimum of space.


Characteristics:

◆ Economical and safe anchoring

The M30/D20 climbing cones have been designed especially for single-sided concreting using

SCB180 in dam construction, and to allow the transfer of high tensile and shear forces into the still

fresh, unreinforced concrete. Without wall-through tie-rods, finished concrete is perfect.

◆ Stable and cost-effective for high loads

generous bracket spacings allow large-area formwork units with optimal utilization of the bearing

capacity. This leads to extremely economical solutions.

◆ Simple and flexible planning

With SCB180 single-sided climbing formwork, circular structures can also be concreted without

undergoing any large planning process. Even use on inclined walls is feasible without any special

measures because additional concrete loads or lifting forces can be safely transferred into the

structure.




Q:New shear wall template support
The new shear wall template support mainly consists of vertical beam, beam, joint, through the wall nail, yin and yang angle, beam bolt composition. Vertical beam is 2.6-3.0 meters scalable to meet the needs of different layers; beams also have six kinds of specifications, to meet the needs of different lengths of the wall; yin and yang angle is the same size specifications, are 300 * 300, So workers do not need to distinguish between yin and yang angle, and casually take a direct use on it.
Q:What is a template for pulling bolts
To the stencil fixed, a two-headed round bar, insert the template, the two tied to the nut
Q:What is the meaning of the template bearing surface elevation in the bridge specification?
Elevation refers to the distance from a point along the vertical line to the absolute base plane, said the absolute elevation, referred to as the elevation. The distance from a point along a vertical line to a hypothetical quasi-base surface is assumed to be an elevation.
Q:Template support product features
Keel tight and flexible connection not only easy to operate, but also a solid structure. The freely stretchable keel allows you to adapt to any size. The clever self-locking of the column and keel is not only simple but also firmer.
Q:Does the template support of the beamboard contain the full red scaffolding under the beam?
According to the above said, the scaffolding of the ultra-high fee refers to the building as a whole more than 25 (remember not clear), so that the height of the frame exceeds the quota, so to calculate, and the template support of the ultra- High height (as if more than 4m), for example, a building forty meters high, but the height of only three meters, it only calculated scaffolding ultra-high, and not calculate the template high, if a single high ten meters Of the plant and the like, it only calculates the template is high and does not calculate the scaffolding ultra high;
Q:Reinforced concrete shear wall is supported by the use of prefabricated concrete strips as a support on both sides of the template, the country is allowed to use
Reinforced concrete shear wall support commonly known as: reinforced concrete rods. The use of prefabricated concrete strips as a support on both sides of the template, the state allows the use. But in the case of waterproof requirements should not be used to avoid causing moisture into the room with the concrete into the room, affecting the impermeability level. There are waterproof requirements when the general use of water bolts, end welding template limit card. Reinforcement limit concrete card card strength grade in line with the requirements of the shear wall, the length of the bar to meet the thickness of the protective layer can be. The state does not expressly regulate, but provides that any support does not affect the quality of concrete pouring and the use requirements.
Q:A load that can be sustained by a fastener
The requirements of the construction template are calculated according to the area of the contact surface between the concrete and the template, and then the template coefficient (empirical) which is not in contact with the concrete is taken into consideration in consideration of the loss of the template, the turnover turnover and the turnover.
Q:Main and vice keel upgrade modification - the new building template support birth opportunity
Now too many products are updated, not that the traditional bad, but we should take its essence, to its dregs. On the basis of the traditional to do some changes, closer to our present habits, the use of habits. Times in the development of information in the explosion, then our products are also big step forward. Our new roof support is composed of the main keel, vice keel, supporting the mandrel, the cross bar, the main keel can be free to stretch, to meet the size of different rooms, this advantage is that a different layer can be satisfied, do not need Too many specifications, simple operation, versatility. And with a card slot and vice keel connection, is to prevent the main and vice keel sliding between.
Q:Scaffolding structure template support frame type
(1) single pole support frame; 2) double pole support frame; 3) lattice pillar support frame (support frame formed by lattice column group); 4) mixed pillar support frame (mixed with single Pole, double pole, lattice column support frame).
Q:How to use template support?
According to your picture, you can determine this is the cast-in-place concrete board full of support. Generally set full support, the distance between the support in general according to the vertical and horizontal 600mm spacing to consider, the lower part of the distance from the standing surface of 200mm set sweep, the middle set a horizontal bar, the upper part of the beam at the end of the set of cross bar, mainly play a role in supporting the beam plate.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords