Product Description:

Single-side Climbing Bracket SCB180

With CNBM SCB 180 climbing systems, the loads from the fresh concrete pressure are

transferred through the brackets by means of V-strongbacks and compression braces into the

scaffold anchors.

Typical applications for the SCB 180 are dams, locks, cooling towers, pier heads, tunnels, and

bank vaults.

The formwork is simply tilted backwards when striking takes place. The 1.80 m wide bracket

requires only a minimum of space.


Characteristics:

◆ Economical and safe anchoring

The M30/D20 climbing cones have been designed especially for single-sided concreting using

SCB180 in dam construction, and to allow the transfer of high tensile and shear forces into the still

fresh, unreinforced concrete. Without wall-through tie-rods, finished concrete is perfect.

◆ Stable and cost-effective for high loads

generous bracket spacings allow large-area formwork units with optimal utilization of the bearing

capacity. This leads to extremely economical solutions.

◆ Simple and flexible planning

With SCB180 single-sided climbing formwork, circular structures can also be concreted without

undergoing any large planning process. Even use on inclined walls is feasible without any special

measures because additional concrete loads or lifting forces can be safely transferred into the

structure.




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the specific distance between the pole spacing supported by the template and the distance between the upper and lower horizontal bars?
Construction engineering template works. Height of 6 meters long and 8 meters. Pole spacing. Horizontal spacing should be how much
Q:Why can not the scaffolding stand with the stent?
The use of pier body construction rod hole, so that scaffolding and pier body consolidation, improve stability
Q:Scaffolding structure template support frame type
Fastener, bowl button and door steel scaffold material can be used to construct the template support frame, and have their own characteristics. According to their structure can be classified as follows: (1) by type of structure 1) pillar support frame (pillar bearing structure);
Q:Building template support structure has been widely used
The construction quality of the new building construction module supporting system can be completely comparable to the quality effect of the large steel formwork. It is through any combination of various locks, all the template firmly solidified into a whole, due to the cross-sectional size of the various parts of the standard uniform, the vertical deformation of the wall are within 3mm (advanced plaster). After removing the template, the wall fully achieved the effect of clear water concrete. It is possible to avoid the plastering process of the later stage of the wall decoration, not only save the material, but also greatly reduce the cost of labor costs.
Q:How to prevent the template support collapsed
The third is to increase the supervision of the construction of high template. Local construction departments should actively promote the grid management, a clear focus on regional monitoring and key areas. For large templates and other dangerous projects, should increase the frequency of inspection, found that timely supervision and rectification, effectively curb the occurrence of major accidents.
Q:How to use template support?
Can be linked to this person. This is Shengchuan building materials manufacturers
Q:Main and vice keel upgrade modification - the new building template support birth opportunity
Now too many products are updated, not that the traditional bad, but we should take its essence, to its dregs. On the basis of the traditional to do some changes, closer to our present habits, the use of habits. Times in the development of information in the explosion, then our products are also big step forward. Our new roof support is composed of the main keel, vice keel, supporting the mandrel, the cross bar, the main keel can be free to stretch, to meet the size of different rooms, this advantage is that a different layer can be satisfied, do not need Too many specifications, simple operation, versatility. And with a card slot and vice keel connection, is to prevent the main and vice keel sliding between.
Q:After the pouring with the template removed and then how to support
Do not remove the template, but in the template design and erection must be considered in the post-pouring stand alone erection in order to facilitate the future beam, board concrete to a certain strength after the other full scaffolding removed, leaving the part of the back with the template and support. (Theoretically requires beams and plates of concrete strength to reach 100% to be removed). So that the support design of the post-pouring zone takes into account that the value of the load must meet the requirements of this part to support the independent composite and take the necessary observation and maintenance measures for the template and support. This approach allows the concrete at the post- The template is disturbed, resulting in adverse damage to the structural requirements of the bad.
Q:Template Support System Safety Control
Template support system must strictly implement the relevant provisions of the national standard, take a sound and reliable security technical measures, and completely eliminate the template support system collapse occurred. Scientific management and advanced technology is to do a good job of template support system effective guarantee, to rely on scientific management and technology, can really control the template support system strength, stiffness and stability
Q:How to calculate the bearing capacity of the template support
(Static load + dynamic load) * safety factor = construction load. A fastener carrying 3 tons.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range