Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable H05Z-K

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1000 m
Supply Capability:
30000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable

Production Introduction for Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable:


Voltage Rate: 300/500V, 450/750V

Cores: 1~7 cores

Range of Nominal cross section: 0.50 mm2 ~ 120 mm2

Conductor: Class 5 fine annealed copper wires or tinned copper wires

Constructions:Insulation: XLPE or LSZH compound

           Sheath: LSZH compound

Core color: Brown, Grey, Black, Blue, Green/Yellow or others on request

Packing: 100 meter/roll for small size, wooden drum for big size, or as per requirement

Max. Operating Temperature: 90 ℃ , can be 105 ℃ ,110 ℃ and 125 ℃ as per

Application for Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable :

The wires are flexible conductors used for the stranding of electric switchboards or lighting

systems, etc, they are particularly recommended where fire risks are important, and for public

installations or closed areas, also fit sensible buildings such as datas and electronic rooms.

 

Production Standard for Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable:

IEC 60227, BS6500, VDE0281, GB/T 5023, JB/T8734

 

The  Feature for Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable:

The cable can be of flame retardance, fire resistance and other property

 

Packing photo for Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable:



Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable H05Z-K

Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable H05Z-K

FAQ For Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable :

 

Q1:What is the Production Capacity for your factory?

About100 kilometer every day

 

Q2: What is the Minimum Order Quantity For Single Core PVC Insulated Cable 450 /750 V?

MOQ: 10000 meters for small size, 5000 meters for middle size, 1000 meters for big size

 

Q3:What is the delivery time for these cables?

10~15 working days

 

Q4: What standards is the product complying with?

    We can produce thousands of electric wires and power cables complying with different standards, such as: GB, JB , IEC, BS, AS/NZS, VDE, UL ETC.


 

Q4: What standards is the product complying with?

    We can produce thousands of electric wires and power cables complying with different standards, such as: GB, JB , IEC, BS, AS/NZS, VDE, UL ETC.



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the difference between KVV and VV cables and are they clearly different?
Eight or six no less, the first good fire retardant pipe on the line, the box can be opened after the slot
Q:What does the cable (YJV-5 * 6) mean?
ZR-YJV22-4 * 16 is ZR armored flame retardant power cable, YJV22 copper core PVC insulated steel tape armored PVC sheathed power cable, 4 * 16 is 4 core 16 (mm2) section.
Q:How to convert the computer's audio and video to cable TV signals. Through the cable television transmission to the 40 TV (hurry)
Fire paint is esterified by epoxy resin plant acid, respectively, with iron oxide red, iron oxide black, zinc yellow and other pigments and physical paint grinding, and adding driers, to, butanol modulation
Q:Power cable inspection, how many meters should be sampled?
meaning: ZR represents the flame retardant properties YJ said cross-linked polyethylene insulation V said PVC jacket ZR-YJV table red copper core XLPE insulated PVC sheathed power cable 4 * 70 + 1 * 35 said 4 core 70mm2 + 1 core 35mm2
Q:What is the meaning of "cable tray: 200 * 100 middle strip" in electrical engineering
About 35m distance, with the copper clad aluminum wire, so that basically do not affect the electric car charging voltage. The best use of plastic leather wrapped copper wire, if the copper wire, then the wire will increase slightly, but will not affect the electric car charging. Only the line is too long, the wire sagging pull the charger will be the output of the end of the wire, which may be the charger inside the solder joint pull off. To solve this problem is to extend the output wire, the charger should be fixed to the output line, so as not to affect the charger. I hope my answer will help you. -------------------------------------------------- -------------------------------------------------- -------------------- The above content is based on "stupid do not know" personal experience to write, only on behalf of personal views and opinions, no one shall arbitrarily modify, It is forbidden to plagiarize. Please refer to the source.
Q:The telephone line, TV line, cable, power lines are worn to a wire tube, what will happen?
This is the wiring of the cable wiring formulas: the next five is 10 square below the current per square 5A current wiring, one hundred and twenty is more than 100 square per square 2A, 25335 three circles, meaning 10 (Excluding) or more, 25 square feet per square 3A wiring, 35 square (inclusive) or more, 100 square (excluding) the following per square 4A line, that is, 25 square feet, 35 square feet per square by 3A or 4A wiring line.
Q:Power cable casing buried what are the requirements
2 direct laying cable way, should meet the following requirements: 1 cable should be laid in the trenches, and should be along the length of the cable on the next, next to the side of the shop with a thickness of not less than 100mm soft soil or sand 2 along the length of the cable should cover the width of not less than 50mm on both sides of the cable protection board, protective board should adopt concrete 3 urban cable buried in the laying, it is appropriate in the protection board laying eye-catching signs 4 in the suburbs or open areas, along the cable path of the line spacing of 100m, corner or joint parts, should be erected obvious signs or signs 5 when the use of cable through the corrugated pipe laying in the trenches, should be along the full length of the bellows casting thickness of not less than 100mm of concrete, the width should not be less than 50mm outside the tube, the cable can not armor 3 buried in the non-frozen soil area, the cable embedding depth should meet the following requirements: 1 cable to the basement of the basement structure, not less than 03m 2 cable skin to the ground depth, not less than 07m; when located in the carriageway or farmland, should be properly deepened, and should not be less than 10m 4 buried in the permafrost area, should be buried below the permafrost layer, when not buried can be buried in the soil drainage of dry frozen soil or backfill, but also take other measures to prevent damage to the cable The 5 Directly laying the cable, is strictly prohibited in the underground pipe is just above or below The minimum distance between cable and cable, pipe, road, structure, etc shall be in accordance with Table 535 Table 535 Permissible minimum distance between cable and cable, pipe, road, structure, etc (m)
Q:Paint trunking, galvanized trunking: that good? expensive? Their advantages and disadvantages?
There are four kinds of lines are then connected to the S terminal line terminal line D AV Cable There wherein component color line terminal S and AV Cable used on PSP2000 machine models the XMB output only able to listen to music and video player can not play Delays Shanghai Gan high wet die for splashing simulation games and armpit homebrew terminal D line in the high definition television generally have much use is the most common color components of the line connector 2 are 5 audio support three video lines by able to run all games and homebrew on line scan TV (provided that set - external display settings - select progressive scan mode) If the TV does not support progressive scan, and it can only S-Video and AV terminals as well, so before use Please determine whether the TV supports progressive scan PSP3000 host no more than the above restrictions can use all the features now on the market to sell the line is generally divided into original and assembled, the effect is similar in use, in addition to the D terminal, because it is high-end line, so few assembled, prices are more expensive, probably about more than 500 pieces, AVS component cable original price of the basic recommendations are between 240-360 basic components are assembled in line to buy 30 Around a lot to find on Taobao reputable sellers use effect is good to see you choose which of
Q:What is the role of patch panels generally, why should the switch connected?
If you are in a small city or town, go to some of the aluminum core series of cable (if you are in a small city or town), if you are in a big city, ask high, with copper core BV, BVVB, RV, VV series line Better, according to the level of regional economic development to purchase the cable, wire type.
Q:Wire inside the two lines, red and black, black line is the line of fire or zero line ah?
. 1.8.7 / 10kV U value of 10KV, which can withstand the maximum voltage of 12KV8.7 / 15kV U value of 15KV, which can withstand the maximum voltage of 17.5KV2.8.7 / 10kV is 10KV system in the first Class II cable (fault time can be greater than 1 minute) 8.7 / 15kV is the first type of cable in the 15KV system (failure time is not more than 1 minute) 3.U0 / UU0 - conductor and insulation shield between the voltage U - the The voltage between the conductors is two, the cable is usually a few or several groups of wires [at least two] stranded from the rope similar to the cable, each group of wires insulated from each other, and often around a central twist The entire outer package has a highly insulated cover. Multiple in the air or in the ground, underwater, for telecommunications or power transmission.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range