Single conductor Type UD Cable- Aluminum Conductor

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
100000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1.Single conductor Type UD Cable- Aluminum Conductor

1.1 Applications
Directly buried or installed in ducts for 600 volt secondary distribution.
1.2 Standards
Secondary UD single conductor 600V cable meets or exceeds the following ASTM specifications.

  B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
  B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
  B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
  B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
  Secondary UD single conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
  "USE-2" per UL 854 available upon request.
1.3 Options
  Cable in Duct (CIC)
  Abrasion Resistant
Ampacity
90oC conductor temperature, 20oC ambient, RHO factor 90, 100% load factor for three conductor triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
1.4 Specification

Item Size AWG or Stranding Insulation Outside Dia. Weight Per KM
MCM mm mm Kg
Princeton 6 7/W 1.524 7.57 66.96
Mercer 4 7/W 1.524 8.76 95.23
Clemson 2 7/W 1.524 10.24 138.38
Kenyon 1 19/W 2.032 13.26 220.22
Harvard 1/0 19/W 2.032 12.24 181.54
Yale 2/0 19/W 2.032 14.38 266.35
Tufts 3/0 19/W 2.032 15.65 322.90
Beloit 4/0 19/W 2.032 17.07 394.32
Hofstra 250 37/W 2.413 19.00 471.70
Gonzaga 300 37/W 2.413 20.35 552.05
Rutgers 350 37/W 2.413 21.62 629.42
Emory 500 37/W 2.413 24.87 861.55
Duke 600 61/W 2.794 27.58 1043.09
Furman 700 61/W 2.794 29.34 1196.35
Sewanee 750 61/W 2.794 30.18 1272.24
Fordham 1000 61/W 2.794 33.96 1650.19

 
2.Duplex Conductor Type URD Cable-Aluminum Conductor2.1 Applications
Directly buried or installed in ducts for 600 volt secondary distribution.
2.2 Standards
Secondary UD duplex conductor 600V cable meets or exceeds the following ASTM specifications.
  B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
  B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
  B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
  B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
  Secondary UD duplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
  "USE-2" per UL 854 available upon request.
2.3 Options
  Cable in Duct
  Abrasion Resistant
Ampacity
90oC conductor temperature, 20oC ambient, RHO 90, 100% load factor. All yellow extruded stripe cable is XLP insulation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
2.4 Specification

Item Phase Conductor size Phase Conductor Stranding Phase Conductor Insulation Thickness Neutral Size Neutral Stranding Neutral Insulation Thickness Single Phase Conductor Single Phase Conductor Weight Per Km
AWG mm AWG mm mm mm Kg
Bard 8 7/w 1.524 8 7/w 1.524 6.65 13.31 113.09
Claflin 6 7/w 1.524 6 7/w 1.524 7.59 15.14 135.41
Delgado 4 7/w 1.524 4 7/w 1.524 8.76 17.53 191.95
Everett 2 7/w 1.524 2 7/w 1.524 10.24 20.47 281.23

3.Triplex Conductor Type URD Cable- Aluminum Conductor
3.1 Applications
Directly buried or installed inducts for 600 volt secondary distribution.
3.2 Standards
Secondary UD triplex conductor 600V cable meets or exceeds the following ASTM specifications.
  B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
  B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
  B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
  B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
  Secondary UD triplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
  "USE-2" per UL 854 available upon request.
3.3 Options
  Cable in Duct (CIC)
  Abrasion Resistant
Ampacity
90oC conductor temperature, 20oC ambient, RHO 50, 100% load factor for three conductor triplex with neutral carrying only unbalanced load. Technical data for cable with solid black neutral is identical to yellow extruded stripe data. All yellow extruded stripe cable is XLP insulation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
3.4 Specification

Item Phase Conductor size Phase Conductor Stranding Phase Conductor Insulation Thickness Neutral Size Neutral Stranding Neutral Insulation Thickness Single Phase Conductor Single Phase Conductor Weight Per Km
AWG mm AWG mm mm mm Kg
Erskine 6 7/w 1.524 6 7/w 1.524 7.59 16.41 212.78
Vassar 4 7/w 1.524 4 7/w 1.524 8.76 19.15 302.06
Stephens 2 7/w 1.524 4 7/w 1.524 10.24 21.39 392.83
Ramapo 2 7/w 1.524 2 7/w 1.524 10.24 22.20 437.47
Brenau 1/0 19/w 2.032 2 7/w 1.524 13.26 27.03 607.10
Bergen 1/0 19/w 2.032 1/0 19/w 2.032 13.26 28.78 691.92
Converse 2/0 19/w 2.032 1 19/w 2.032 14.38 29.82 746.98
Hunter 2/0 19/w 2.032 2/0 19/w 2.032 14.38 31.19 833.28
Hollins 3/0 19/w 2.032 1/0 19/w 2.032 15.65 32.41 901.73
Rockland 3/0 19/w 2.032 3/0 19/w 2.032 15.65 33.93 1008.86
Sweetbriar 4/0 19/w 2.032 2/0 19/w 2.032 17.07 35.28 1099.63
Monmouth 4/0 19/w 2.032 4/0 19/w 2.032 17.07 37.01 1232.06
Pratt 250 37/w 2.413 3/0 19/w 2.032 19.00 39.07 1328.78
Wesleyan 350 37/w 2.413 4/0 19/w 2.032 21.62 44.09 1735.01
Holyoke 500 37/w 2.413 300 37/w 2.413 24.87 51.00 2391.22
Rider 500 37/w 2.413 350 37/w 2.413 24.87 51.69 2474.54
Fairfield 750 61/w 2.794 500 37/w 2.413 30.1752 52.98 3428.35

4.Quadruplex Conductor Type URD Cable & Mobile Home Feeder
4.1 Applications
Directly buried or installed in ducts for 600 volt secondary distribution.
4.2 Standards
Secondary UD quadruplex conductor 600V cable meets or exceeds the following ASTM specifications.
  B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
  B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
  B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
  B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
  Secondary UD quadruplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
  "USE-2" per UL 854 available upon request.
4.3 Options
  Cable in Duct (CIC)
  Abrasion Resistant
Ampacity
To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
4.4 Specification

Item Phase Conductor size Phase Conductor Stranding Phase Conductor Insulation Thickness Neutral Size Neutral Stranding Neutral Insulation Thickness Single Phase Conductor Single Phase Conductor Weight Per Km
AWG mm AWG mm mm mm Kg
Tulsa 4 7 1.524 4 4 1.524 8.76 21.16 383.90
Dyke 2 7 1.524 4 4 1.524 10.24 23.83 514.85
Wittenberg 2 7 1.524 2 2 1.524 10.24 24.71 558.00
Notre Dame 1/0 19 2.032 2 2 1.524 13.26 30.18 805.01
Purdue 1/0 19 2.032 1/0 1/0 2.032 13.26 32.00 886.85
Syracuse 2/0 19 2.032 1 1 2.032 14.38 33.43 988.03
Lafayette 2/0 19 2.032 2/0 2/0 2.032 14.38 34.72 1071.36
Swarthmore 3/0 19 2.032 1/0 1/0 2.032 15.65 36.32 1197.84
Davidson 3/0 19 2.032 3/0 3/0 2.032 15.65 37.77 1300.51
Wake Forest 4/0 19 2.032 2/0 2/0 2.032 17.07 39.62 1456.75
Earlham 4/0 19 2.032 4/0 4/0 2.032 17.07 41.22 1586.21
Slippery Rock 350 37 2.413 4/0 4/0 2.032 21.62 49.40 2297.47
Wofford 500 37 2.413 350 350 2.413 21.62 59.64 3234.91
Windham 750 61 2.794 500 500 2.413 24.87 72.39 3782.50

 
 
 


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:wireless Internet disconnects when power cable is disconnected why?
I am assuming that you are using windows, If you haven't done so already, right click on the battery on the right hand of your task bar and click on the power options. now, click on CHANGE PLAN SETTINGS Then click on CHANGE ADVANCED POWER SETTINGS a new window should pop up, look for wireless adaptor settings and select maximum performance, This could be your answer but then again I'm not sure what you have already attempted.
Q:Can you plug a power supply 6 pin cable into a 4 pit motherboard slot?
No, okorder.com. I know they have extensions so they should have what you are looking for.
Q:Car Audio Installation and Setup?
I'm not 100% sure but I think that doesnt matter. What matters is the amount of batteries you have. There is a significant difference between 500 to 1000 watts. But it depends on what enclosure is being used that makes it louder...much louder in some cases.
Q:Where can I find a replacement power cable for a Technics SL-D20 Turntable?
That type of connector was common before the IEC style cable became the standard. Perhaps you can scrounge some more tag sales or estate sales, friends garages and attics. You might check to see if there is an electronics surplus store in your town. Those guys never throw anything away.
Q:If i buy a Ipod Touch in the USA or Indonesia can I use a power cable from Australia with it?
well idk about quality, i mean they all SHOULD be the same, they are from the same company and they're pretty much the same thing...so idk about that, but USA is USUALLY a good choice. I think if u get one in Bali they should have it automatically set up to the language they speak, or else why would apple make them international if people can't even understand what they say? idk what you mean by power calble, however, the standard voltage in Australia may be more or less then USA. There are usually products that you can buy at best buy or any electronic store that allow you to plug you're ipod into a different countries plug so that you can charge it and it wont blow out just ask a representative at best buy ;)
Q:I just had a power outage and now my comcast cable wont work?
Reset your cable box. See if there is a reset option, if not, unplug your box and wait 30 seconds. Plug it back in, but do not turn it on until it boots all the way up. When it is booted up, the clock on the front will display with the correct time. At that time, turn it on, and see if it works.
Q:I used the wrong power cable on my external hardrive, is there any hope fixing it?
sond a thugh blown it but if you take it to a store and see if they can recover the data of the platters, you may get lucky if you get the right people?
Q:My amp is burning the power cables no matter what guage wire i use.?
Take it to a repair shop
Q:Please help, need to know the name of a power cable.?
If you are in the UK, it is 13amp insulated, power cable with live, neutral and earth wires.
Q:The living room to the bedroom cable does not work
1 TV inside the 400V filter capacitor damage 2 audio and video cable connection is not good or poor quality 3 you put the TV volume dots, set-top box volume can be improved

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range