1.Single conductor Type UD Cable- Aluminum Conductor

1.1 Applications
Directly buried or installed in ducts for 600 volt secondary distribution.
1.2 Standards
Secondary UD single conductor 600V cable meets or exceeds the following ASTM specifications.

  B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
  B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
  B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
  B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
  Secondary UD single conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
  "USE-2" per UL 854 available upon request.
1.3 Options
  Cable in Duct (CIC)
  Abrasion Resistant
Ampacity
90oC conductor temperature, 20oC ambient, RHO factor 90, 100% load factor for three conductor triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
1.4 Specification

Item Size AWG or Stranding Insulation Outside Dia. Weight Per KM
MCM mm mm Kg
Princeton 6 7/W 1.524 7.57 66.96
Mercer 4 7/W 1.524 8.76 95.23
Clemson 2 7/W 1.524 10.24 138.38
Kenyon 1 19/W 2.032 13.26 220.22
Harvard 1/0 19/W 2.032 12.24 181.54
Yale 2/0 19/W 2.032 14.38 266.35
Tufts 3/0 19/W 2.032 15.65 322.90
Beloit 4/0 19/W 2.032 17.07 394.32
Hofstra 250 37/W 2.413 19.00 471.70
Gonzaga 300 37/W 2.413 20.35 552.05
Rutgers 350 37/W 2.413 21.62 629.42
Emory 500 37/W 2.413 24.87 861.55
Duke 600 61/W 2.794 27.58 1043.09
Furman 700 61/W 2.794 29.34 1196.35
Sewanee 750 61/W 2.794 30.18 1272.24
Fordham 1000 61/W 2.794 33.96 1650.19

 
2.Duplex Conductor Type URD Cable-Aluminum Conductor2.1 Applications
Directly buried or installed in ducts for 600 volt secondary distribution.
2.2 Standards
Secondary UD duplex conductor 600V cable meets or exceeds the following ASTM specifications.
  B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
  B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
  B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
  B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
  Secondary UD duplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
  "USE-2" per UL 854 available upon request.
2.3 Options
  Cable in Duct
  Abrasion Resistant
Ampacity
90oC conductor temperature, 20oC ambient, RHO 90, 100% load factor. All yellow extruded stripe cable is XLP insulation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
2.4 Specification

Item Phase Conductor size Phase Conductor Stranding Phase Conductor Insulation Thickness Neutral Size Neutral Stranding Neutral Insulation Thickness Single Phase Conductor Single Phase Conductor Weight Per Km
AWG mm AWG mm mm mm Kg
Bard 8 7/w 1.524 8 7/w 1.524 6.65 13.31 113.09
Claflin 6 7/w 1.524 6 7/w 1.524 7.59 15.14 135.41
Delgado 4 7/w 1.524 4 7/w 1.524 8.76 17.53 191.95
Everett 2 7/w 1.524 2 7/w 1.524 10.24 20.47 281.23

3.Triplex Conductor Type URD Cable- Aluminum Conductor
3.1 Applications
Directly buried or installed inducts for 600 volt secondary distribution.
3.2 Standards
Secondary UD triplex conductor 600V cable meets or exceeds the following ASTM specifications.
  B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
  B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
  B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
  B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
  Secondary UD triplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
  "USE-2" per UL 854 available upon request.
3.3 Options
  Cable in Duct (CIC)
  Abrasion Resistant
Ampacity
90oC conductor temperature, 20oC ambient, RHO 50, 100% load factor for three conductor triplex with neutral carrying only unbalanced load. Technical data for cable with solid black neutral is identical to yellow extruded stripe data. All yellow extruded stripe cable is XLP insulation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
3.4 Specification

Item Phase Conductor size Phase Conductor Stranding Phase Conductor Insulation Thickness Neutral Size Neutral Stranding Neutral Insulation Thickness Single Phase Conductor Single Phase Conductor Weight Per Km
AWG mm AWG mm mm mm Kg
Erskine 6 7/w 1.524 6 7/w 1.524 7.59 16.41 212.78
Vassar 4 7/w 1.524 4 7/w 1.524 8.76 19.15 302.06
Stephens 2 7/w 1.524 4 7/w 1.524 10.24 21.39 392.83
Ramapo 2 7/w 1.524 2 7/w 1.524 10.24 22.20 437.47
Brenau 1/0 19/w 2.032 2 7/w 1.524 13.26 27.03 607.10
Bergen 1/0 19/w 2.032 1/0 19/w 2.032 13.26 28.78 691.92
Converse 2/0 19/w 2.032 1 19/w 2.032 14.38 29.82 746.98
Hunter 2/0 19/w 2.032 2/0 19/w 2.032 14.38 31.19 833.28
Hollins 3/0 19/w 2.032 1/0 19/w 2.032 15.65 32.41 901.73
Rockland 3/0 19/w 2.032 3/0 19/w 2.032 15.65 33.93 1008.86
Sweetbriar 4/0 19/w 2.032 2/0 19/w 2.032 17.07 35.28 1099.63
Monmouth 4/0 19/w 2.032 4/0 19/w 2.032 17.07 37.01 1232.06
Pratt 250 37/w 2.413 3/0 19/w 2.032 19.00 39.07 1328.78
Wesleyan 350 37/w 2.413 4/0 19/w 2.032 21.62 44.09 1735.01
Holyoke 500 37/w 2.413 300 37/w 2.413 24.87 51.00 2391.22
Rider 500 37/w 2.413 350 37/w 2.413 24.87 51.69 2474.54
Fairfield 750 61/w 2.794 500 37/w 2.413 30.1752 52.98 3428.35

4.Quadruplex Conductor Type URD Cable & Mobile Home Feeder
4.1 Applications
Directly buried or installed in ducts for 600 volt secondary distribution.
4.2 Standards
Secondary UD quadruplex conductor 600V cable meets or exceeds the following ASTM specifications.
  B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
  B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
  B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
  B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
  Secondary UD quadruplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
  "USE-2" per UL 854 available upon request.
4.3 Options
  Cable in Duct (CIC)
  Abrasion Resistant
Ampacity
To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
4.4 Specification

Item Phase Conductor size Phase Conductor Stranding Phase Conductor Insulation Thickness Neutral Size Neutral Stranding Neutral Insulation Thickness Single Phase Conductor Single Phase Conductor Weight Per Km
AWG mm AWG mm mm mm Kg
Tulsa 4 7 1.524 4 4 1.524 8.76 21.16 383.90
Dyke 2 7 1.524 4 4 1.524 10.24 23.83 514.85
Wittenberg 2 7 1.524 2 2 1.524 10.24 24.71 558.00
Notre Dame 1/0 19 2.032 2 2 1.524 13.26 30.18 805.01
Purdue 1/0 19 2.032 1/0 1/0 2.032 13.26 32.00 886.85
Syracuse 2/0 19 2.032 1 1 2.032 14.38 33.43 988.03
Lafayette 2/0 19 2.032 2/0 2/0 2.032 14.38 34.72 1071.36
Swarthmore 3/0 19 2.032 1/0 1/0 2.032 15.65 36.32 1197.84
Davidson 3/0 19 2.032 3/0 3/0 2.032 15.65 37.77 1300.51
Wake Forest 4/0 19 2.032 2/0 2/0 2.032 17.07 39.62 1456.75
Earlham 4/0 19 2.032 4/0 4/0 2.032 17.07 41.22 1586.21
Slippery Rock 350 37 2.413 4/0 4/0 2.032 21.62 49.40 2297.47
Wofford 500 37 2.413 350 350 2.413 21.62 59.64 3234.91
Windham 750 61 2.794 500 500 2.413 24.87 72.39 3782.50

 
 
 


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to identify the quality of the lock of the hotel lock?
If you are using a cable that is suitable for direct burial, you do not need a casing. But in the place into the building, should be casing, in order to protect. General steel pipe can be.
Q:Ipad charge does not enter the charge does not support this accessory charge
Friends, my task, hope to adopt! Answer: sorghum (Liang) explained: the poles are relatively high, beautiful riding on the poles is in the height of their own beautiful, so according to the meaning of harmony, the answer is sorghum.
Q:Cable WDZ-YJFE2 (4X185 + 1X95) what does it mean
Bracket spacing of the general level of not more than 2m, vertical not more than 1.5m according to the number of cable the number of levels can be used 1.5m a vertical 1m a relatively insurance
Q:With a i3-2100 desktop computer about how much money. To have a separate graphics card. Give a configuration alone, no more than 4000
Yellow is the ground, the other two casually, mainly to see when you plug there is the line of fire, no effect.
Q:How long is the service life of the cable?
cable bridge and other pipes and other facilities shall not share a column (bracket)
Q:What is the installation specification for the cable tray bracket?
In accordance with the requirements of the general requirements of the installation of the switch installation height is 1300mm, the socket is 300mm, air conditioning socket is 1800 ~ 2200mm; wall in accordance with the norms is not allowed to take the horizontal pipeline, so the conventional approach is vertical inside the floor of the pipe is near run.
Q:Power cable 5-color line, respectively, what color, what role?
YJ: cross-linked polyethylene insulation V: PVC sheathed 22: steel tape armor 8.7 / 15KV: rated voltage: 8.7 / 15 kV 3 * 300: three conductor cross-section of 300 square copper conductor Another: such as YJLV Is the aluminum core. Here is not marked what the material is conductor, you can default to copper conductor.
Q:The difference between power cable and overhead cable
His answer is correct! There is overhead cable generally use aluminum core conductor! Because light weight Overhead cable under normal circumstances are 6kV below the cable! If the voltage level is high, you need to do special craft production!
Q:Lighting wire, I do not know is it. The When to use BV1 * 2.5, when to use 2 * 2.5, when to use 3 * 2.5, when to use 4 * 2.5,
Why did not you take this time when you were installed or that it was only a detour
Q:What is the role of patch panels generally, why should the switch connected?
If you are in a small city or town, go to some of the aluminum core series of cable (if you are in a small city or town), if you are in a big city, ask high, with copper core BV, BVVB, RV, VV series line Better, according to the level of regional economic development to purchase the cable, wire type.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range