• Silent Type Perkins Diesel Generating Set System 1
  • Silent Type Perkins Diesel Generating Set System 2
Silent Type Perkins Diesel Generating Set

Silent Type Perkins Diesel Generating Set

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
500 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Silent Type Perkins Diesel Generating Set

Below data sheet is our silent type diesel generator set,this type genset is suitable for those places where with dense population or strict requirements on noise.

SILENT TYPE PERKINS DIESEL GENERATING SET DATA SHEET

Genset Model

Standby Power

Prime Power

Fuel Consumption

Overall Size

Weight

Fuel Tank Capacity

Engine Description

Alternator Model

KVA

KW

KVA

KW

100%    L/H

L x W x H (mm)

KG

L

 Model

Oil Capacity(L)

Coolant Capacity(L)

Stamford

ZOP10PKS

10

8

9

7

2.6

2200x1033x1304

896

160

403A-11G1

4.9

5.2

LSA40VS1

ZOP10PKS

10

8

9

7

2.6

2200x1033x1304

896

160

403D-11G

4.9

5.2

LSA40VS1

ZOP14PKS

14

11

13

10

3.67

2200x1033x1304

956

160

403D-15G

6

6

LSA40VS2

ZOP14PKS

14

11

13

10

3.48

2200x1033x1304

956

160

403A-15G1

6

6

LSA40VS2

ZOP16PKS

16

13

15

12

3.48

2200x1033x1304

956

160

403A-15G2

6

6

LSA40S3

ZOP22PKS

22

18

20

16

5.3

2200x1033x1304

1070

160

404D-22G

10.6

7

LSA40M5

ZOP22PKS

22

18

20

16

5.3

2200x1033x1304

1070

160

404A-22G1

10.6

7

LSA40M5

ZOP30PKS

30

24

27

22

6.7

2200x1033x1304

1087

160

404D-22TG

10.6

9.3

LSA42.3VS2

ZOP33PKS

33

26

30

24

6.98

2300x1133x1376

1270

221

1103A-33

7.9

10.2

LSA42.3VS3

ZOP50PKS

50

40

45

36

10.6

2300x1133x1376

1407

221

1103A-33T/DK83398S

7.9

10.2

LSA42.3M7

ZOP65PKS

65

52

60

48

13.8

2300x1133x1376

1434

221

1104C-44TG2

8

13

LSA42.3L9

ZOP65PKS

65

52

60

48

13.8

2300x1133x1376

1434

221

1103A-33T/DK83399S

7.9

10.2

LSA42.3L9

ZOP75PKS

73

58

65

52

14.8

2300x1133x1376

1547

221

1104A-44TG1

8

13

LSA44.3S2

ZOP88PKS

88

70

80

64

18.4

2300x1133x1376

1560

221

1104A-44TG2

8

13

LSA44.3S3

ZOP88PKS

88

70

80

64

18.4

2300x1133x1376

1560

221

1104C-44TAG1

8

12.6

LSA44.3S3

ZOP100PKS

100

80

90

72

20.5

2700x1133x1666

1735

300

1104C-44TAG2

8

12.6

LSA44.3S4

ZOP110PKS

110

88

100

80

24

2700x1133x1666

1750

300

1104C-44TAG2

8

12.6

LSA44.3S5

ZOP150PKS

150

120

135

108

29.9

3600x1333x2040

2864

685

1106A-70TG1

16.5

21

LSA44.3M8

ZOP158PKS

158

126

142

115

39.7

3600x1333x2040

2864

685

1106D-E70TAG2

16.5

21

LSA44.3L10

ZOP165PKS

165

132

150

120

33.4

3600x1333x2040

2864

685

1106A-70TAG2

16.5

21

LSA44.3L10

ZOP175PKS

175

140

160

128

42.3

3600x1333x2040

2864

685

1106D-E70TAG3

16.5

21

LSA44.3L12

ZOP200PKS

200

160

180

144

41.6

3600x1333x2040

2904

685

1106A-70TAG3

16.5

21

LSA46.3S2

ZOP200PKS

200

160

180

144

49.3

3600x1333x2040

2959

685

1106A-E70TAG4

16.5

21

LSA46.3S2

ZOP220PKS

220

176

200

160

45.8

3600x1333x2040

2959

685

1106A-70TAG4

16.5

21

LSA46.3S3

ZOP220PKS

220

176

200

160

44.6

4100x1490x2000

4500

1100

1506A-E88TAG1

41

29.6

LSA46.3S3

ZOP250PKS

250

200

225

180

48.6

4100x1490x2000

4500

1100

1506A-E88TAG2

41

29.6

LSA46.3S4

ZOP275PKS

275

220

250

200

50

4100x1490x2000

4500

1100

1506A-E88TAG3

41

29.6

LSA46.3S5

ZOP300PKS

300

240

275

220

60.2

4100x1490x2000

4600

1100

1506A-E88TAG4

41

33.2

LSA46.3M7

ZOP330PKS

330

264

300

240

64.9

4100x1490x2000

4600

1100

1506A-E88TAG5

41

33.2

LSA46.3M8

ZOP400PKS

400

320

350

280

70

4500x1583x2200

4724

1200

2206A-E13TAG2

40

51.4

LSA46.3L11

ZOP400PKS

400

320

350

280

70

4500x1583x2200

4724

1200

2206C-E13TAG2

40

51.4

LSA46.3L11

ZOP450PKS

450

360

400

320

82.7

4500x1583x2200

4860

1200

2206A-E13TAG3

40

51.4

LSA47.2S4

ZOP450PKS

450

360

400

320

82.7

4500x1583x2200

4860

1200

2206C-E13TAG3

40

51.4

LSA47.2S4

ZOP500PKS

500

400

450

360

95.6

4700x1583x2200

5039

1200

2506A-E15TAG1

62

58

LSA47.2S5

ZOP500PKS

500

400

450

360

95.6

4700x1583x2200

5039

1200

2506C-E15TAG1

62

58

LSA47.2S5

ZOP550PKS

550

440

500

400

106

4700x1583x2200

5166

1200

2506A-E15TAG2

62

58

LSA47.2M7

ZOP550PKS

550

440

500

400

106

4700x1583x2200

5166

1200

2506C-E15TAG2

62

58

LSA47.2M7

ZOP650PKS

650

520

600

480

126.6

4700x1583x2200

5993

1450

2806C-E18TAG1A

87

61

LSA47.2L9

ZOP660PKS

660

528

600

480

126.6

4700x1583x2200

5993

1450

2806A-E18TAG1A

87

61

LSA47.2L9

ZOP700PKS

700

560

650

520

129.3

4700x1583x2200

6041

1450

2806A-E18TAG2

87

61

LSA49.3S4

ZOP825PKS

825

660

750

600

152.3

6058x2438x2591

10370

1800

4006-23TAG2A

113.4

140

LSA49.3M8

ZOP880PKS

880

704

800

640

171.8

6058x2438x2591

10400

1800

4006-23TAG3A

113.4

140

LSA49.3M8

ZOP1000PKS

1000

800

900

720

188

6058x2438x2591

11667

1400

4008TAG1A

153

234

LSA49.3L9

ZOP1100PKS

1100

880

1000

800

215.2

6058x2438x2591

12030

1400

4008TAG2

153

234

LSA49.3L10

ZOP1100PKS

1100

880

1000

800

215.2

6058x2438x2591

12030

1400

4008TAG2A

153

234

LSA49.3L10

ZOP1250PKS

1250

1000

1125

900

237.2

6058x2438x2591

12310

1400

4008-30TAG3

153

234

LSA50.2M6

ZOP1375PKS

1375

1100

1250

1000

258.1

12192x2438x2896

17950

3000

4012-46TWG2A

177

187

LSA50.2M6

ZOP1500PKS

1500

1200

1375

1100

279.1

12192x2438x2896

18205

3000

4012-46TWG1A

177

274

LSA50.2L7

ZOP1500PKS

1500

1200

1375

1100

279.1

12192x2438x2896

18205

3000

4012-46TWG3A

177

187

LSA50.2L7

ZOP1600PKS

1600

1280

1500

1200

299

12192x2438x2896

18435

3000

4012-46TWG4A

177

187

LSA50.2L8

ZOP1650PKS

1650

1320

1500

1200

299

12192x2438x2896

18435

3000

4012-46TAG2A

177

274

LSA50.2L8

ZOP1875PKS

1875

1500

1688

1350

367.3

12192x2438x2896

19200

3000

4012-46TAG3A

177

274

LSA52.3S5

ZOP2000PKS

2000

1600

1850

1480

381.3

12192x2438x2896

21780

3000

4016TAG1A

237

368

LSA52.3S5

ZOP2000PKS

2000

1600

1850

1480

381.3

12192x2438x2896

21780

3000

4016-61TRG1

237

376

LSA52.3S5

ZOP2250PKS

2250

1800

2000

1600

434

12192x2438x2896

21875

3000

4016TAG2A

237

368

LSA52.3S6

ZOP2250PKS

2250

1800

2000

1600

422

12192x2438x2896

21875

3000

4016-61TRG2

237

376

LSA52.3S6

ZOP2500PKS

2500

2000

2250

1800

467.6

12192x2438x2896

22900

3000

4016-61TRG3

237

376

LSA52.3L9

 


Q:Can you estimate the amount each year in CA.?What are the concerns/issues related to this application.
I don't know about CA but where I live the predominant fuel for permanently installed back up generators is propane. Propane is used because generators can sit idle for weeks or months between power outages. Gasoline and diesel have limited shelf lives and fuel systems can clog with varnishes when not used. Propane has an unlimited shelf life and does not gum up in the carburetor. Natural gas is not available here. In places where it is available natural gas might be preferable to propane. Its impossible to estimate how much fuel you would use in a year. It depends how big your generator is and how many power failures you go through. Most generator manufacturers will tell you how much fuel their products use in an hour.
Q:I have a 4 piston Diesel engine on my generator, I have a nasty oil sludge continue to build up every time, I have flushed the engine with engine flush liqui-moly probably six times, but after it is clean the sludge builds up again in couple of days, I got sick and tired of going down there and get all messed up with nasty oil.The engine produces while smoke continuously, not much but visible enough. I get oil coming onto the air filter, the place smells nasty because of this. The light bulbs flicker when running on the generator, it heats up fast and shuts off when I put load on it as an AC. Can someone please help me out and let me know what to do?
The sludge is an indication of coolant leaking into the oil, as is the white smoke and the fact its over heating, This is due to either a cracked water jacket or sleeve or cylinder head and or gasket, As to what to do? Have it properly diagnosed by a qualified mechanic and if need be rebuild the engine or replace it. As replacing the cylinder sleeves at a reputable shop can cost as much as a new engine.
Q:i means what's happen in diesel generator while just switch on ?
Depends whether it is a battery start or air pressure start. If it's started with a battery, the starter cranks the engine with an electric starter. If it is air started, a solenoid valve is energized, or a hand valve is opened to allow the air pressure to crank the engine with an air turbine. That's the first occurance. There is a definite start-up sequence, in the event the engines fails to start within a given time frame.
Q:Hi, this may be a stupid question but im a city slicker planning on campong and i want to buy a honda generator, What kind of fuel does it use? where do i get it? thanks.
The manual will tell you. I'm sure it will say to use regular gasoline. Buy the gas at your favorite filling station.
Q:i want to put three phase current of two diesel generating sets in only three phase.
Yes you can, just make sure the connections are grounded first!
Q:How to correctly select oil for diesel generator
The lubricity of synthetic oil is higher than that of mineral oil, the friction resistance is small, it is not easy to oxidation, and the detergency is strong
Q:Do you have more insights into this? Japan builds great cars, machinery, tools and high-tech products. Their bullet train is known for almost zero delays in decades. Yet with the Fukushima nuclear power station we have flawed tsunami protection in a location known for powerful earthquakes and tsunamis for at least centuries. I guess no one should be surprised by a ca. 50 feet tsunami at that location. It looks to me like such an obvious blunder. Am I mistaken? - And I mean no offense to the great people of Japan who so valiantly dealt with the terrible tsunami crisis that I admire this very much. Thank you.
Yes you are mistaken. The Fukushima station was designed to withstand average tsunami that had occurred in that area. However the tusnami that hit was much larger than any seen before in that area, or in recorded human history for that matter. Even if you could design a facility to withstand a 200 or even 500 year disaster, eventually you'll encounter something even larger, and then you'll be right back here whining about why did they only design the structure for a 500 year disaster, blah blah blah. Furthermore, such a facility would be prohibitively expensive and over engineered. Was it a risk to only design something to withstand a once-in-a-century event? Sure, but there's no such thing as 0% risk.
Q:I been thinking, and it seems to me our future vehicles would be best suited with a small 1~ liter diesel engine turning a generator to power 4 electric motors at the wheels of the car/truck, just like locomotives use. Advantages would be significantly increased fuel economy, AWD, no transmission and axle weight(offset by weight of batteries, longer lasting diesel engine, easier and cheaper to repair due to small engine size, fewer moving parts, and decreased complexity, regenerative braking, significantly reduced emmissions, less noise, no idling when not moving.Seems the advantages would vastly outweigh the disadvantagesDoes anyone build such a vehicle?
Diesel would be a better alternative both in that high compression engines are more efficient though they also produce more nitrous oxides and diesels can run on biofuels more readily. However you have the problem that you would need a sophisticated computer controlled diesel to avoid the valve clatter while idle that turns a lot of people off. With a full hybrid, the clatter may be minimized but if you wanted the advanced engines, you would have to buy them from Mercedes or Volkswagon. Usually for kit cars, an industrial diesel motors are used ( these are motors designed to run cement mixers, tractors and other equipment ), but the result is a lot of clatter from the valves. Hub motors are in wide use, especially with hybrid buses but they have the down side of being unsprung weight so they severely hamper handling. Trying to do it without hub motors and you might as well go back to the central engine concept. Also the hub motors exist in bus sizes at the moment. Most regenerative braking options are electrical and can only recover a small portion of the power. The Urba-Electric of the 70's used a stepper motor controlled mechanical CVT between the motor and the wheel thereby having mechanical regenerative braking that had higher returns, unfortunately the commercial Electromatic transmission is no longer on the market and such industrial CVT's are limited in their power ratings as they usually used a rubber belt. Hybrids are interesting but they are inherently redundant. They're hardly the ecological salvation for the planet.
Q:I have never had any interest in cars until recently when diesel engines have started to feel like important and valuable power sources moving forward.
They've always been popular in Europe as they have ridiculous fuel taxation. And diesels have traditionally gotten better fuel economy. But these days with direct injected turbo gas engines becoming more prevalent the diesel's fuel economy edge is diminishing. Case in point, the BMW 335i and the BMW 335d. The gas engine gets almost the same mileage as the diesel as you can see here fueleconomy /feg/Find.do?a same deal with the MB 350 as you can see here fueleconomy /feg/Find.do?a Diesels are still quite important for cargo transportation, industrial use, and agriculture, as they have always been. But no offense, but if you're just now finding out about diesel cars, then you've missed the boat by a few decades, diesel cars have been around for a long time.
Q:can they be quiet? I was thinking about buying one sense we seem to have an outage every winter. Just wouldn't want to have an extremely loud generator running disturbing the neighbors
It depends on the model you buy and typically the more expensive models will equip themselves with a better muffler. (Basically each model will describe their decibel rating). I find most generators will provide about as much noise as a lawn mower. So, it is great to run during the day, but you might consider not running them during the night. I also think a diesel motor is just fine to run as a generator- I find the diesel rigs will run at lower RPMS, and last longer. If you are pluging this thing into your home, dont forget to have a professionally installed transfer switch to avoid electricuting the lineman, otherwise you will need to run extension cords to what you want powered.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords