• Sewage Pumps System 1
Sewage Pumps

Sewage Pumps

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Production Introduction:
WQ blockage-free sewage submersible pump(hereinafter as pump) is untegrative motor and pump. Which is manufactured based on absorbing domestic and foreignadvanced technology and advantages. Impeller, designed with hydraulic model and made by precision casting, has the advantages of energy-saving, anti-winding and non-clogging,etc. At the same time, the pumps have a unique effect in the carriage of solid particles and long fibers garbage. Single or dual impeller structure ensures the pump has the higher efficiency when it has bigger flow. So this king of pump is a ideal drainage pumps for industries and cities.

Application:
1. Living waste water discharging
2.Sewage system of municipal works
3.Sewage system in factory and mine corporation
4.Other transportation of none orrosive and diluted medium
5.Temporary floodwater discharging
6.Waste water discharging of public facility
7.Various waterd is chharging system

Work Conditions:
1.Capacity scope:2-1500m³h;
2.System pressure:≤0.6mpa;
3.Medium consistency:≤1.3x10³kg/m³
4.Motor insulation class:IP68;
5.Rotation:clockwise rotation viewed from motor;
6.Rated Speed:970-2900r/min;
7.Head scope: 3-45;
8.Medium temperature:-15℃-+60℃;
9.Medium PH scope:5-9;
10.Motor insulation class:E Grode;


Q:If the suction pump does not have enough suction range, you need to add a vacuum pump to increase the suction stroke. How do you install the suction pipe of the vacuum pump? Water pump impeller is not closed, it is normal that the vacuum pump is unable to pump suction pipe to a vacuum, is it because the water pump outlet pipe connected to the role of the check valve? But the water pump, outlet pipe, check valve sealing performance can achieve the function of non leakage?
The role of the check valve:"[the water pump impeller is not closed" refers to the pump suction pump before the water without water inlet pipe and water outlet pipe gas should be connected] is a connector, a connector, still can make the level surface, in order to prevent the water flow along the pipe, until it reaches the level of the flush, then increased check valve, or pumping up water will not leak?Vacuum suction principle of self suction pump:Assuming that the pump connected with the water inlet of a sealed container, the container has plenty of water, since the start of a water pump, water is thrown out of the water impeller pump body, water inlet seal vessel due to the extraction of water to form a vacuum cavity, this assumption will be connected to vacuum cavity and exposed to atmospheric conditions of water, water at atmospheric pressure under the effect of entry into the vacuum chamber".....
Q:What are the general water pump failure, how to repair?
Troubleshooting of water pumpFirst, the water pump does not cause water analysisThere is air in the inlet pipe and pump body(1) before the water pump is started, the water is not filled enough. Sometimes it seems that the water has been discharged from the vent hole, but the pump shaft is not rotated. The air is completely discharged, resulting in a small amount of air remaining in the inlet pipe or pump body.
Q:You'd better point out the details.... There are 2 best ways of experience and formulaCan you say a simple point, such as multi-stage pump, when the pump is higher than the motor, 30 wire is the next mouth how to do?
For the first time, the pump and motor were placed on the base and not fastened (Cu Zhaozheng);Second times, the pump and motor have been tightened, the inlet and outlet flange bolts are not fastened;Third times, the pump runs 24 hours later.
Q:Troubleshooting of diaphragm pump
The ratio of flow to water weight at a specific weight of --68F. 68F water has a specific gravity of 1Static suction head - the vertical distance from the liquid level to the central line of the pump. The pump shall be above the level of the liquid.Vapor pressure the pressure of all the steam on the free surface of the liquid. In any pump operating system, the operating pressure shall not be lower than the vapor pressure, otherwise the steam will be partially or completely cut off into the pump fluid. Viscosity - because of the presence of friction in the fluid, the property of viscosity gives the fluid resistance to flow.Water hammer action -Water hammer is a sudden power failure, or in the valve closed too fast, due to pressure, flow of inertia, produce water shock waves, like hammer hammer, so called water hammer. The force produced by the flow of water shock waves can sometimes be very large, thereby damaging the valves and pumps. Water hammer effect refers to the inside of the water pipe, the pipe wall is smooth, flow freely. When the opening of the valve suddenly closes, the flow of water to the valve and the tube wall, mainly the valve, will produce a pressure. As the pipe wall is smooth, the subsequent water flow in the role of inertia, the fastest reach the maximum and damage, which is the water conservancy "water hammer effect", that is, "positive water hammer.". This factor should be taken into consideration in the construction of water conservancy pipelines. On the contrary, the valve closed in a sudden opening, it will produce water hammer, called negative water hammer, but also a certain destructive power, but not the former big.. Causes and treatment methods of common failures of diaphragm pumps:
Q:What is the principle of a turbopump?
The working conditions of the turbine are different from those of the medium used, so the structure of the turbine is varied, but the basic working principle is similar. The most important component of a turbine is a rotating element (rotor or impeller) mounted on a turbine shaft with blades uniformly arranged along the circumference. The energy of the fluid is converted into kinetic energy in the flow through the nozzle, and when the fluid passes through the rotor, the fluid impacts the blade and drives the rotor to rotate, thus driving the turbine shaft to rotate. The turbine shaft drives the other machinery directly or through the transmission mechanism, and outputs mechanical work.
Q:Harm of air pump and pump
Minimum starting current when centrifugal pump of such a small impact on the grid but long closed operation will make the liquid in the pump to the pump overheating temperature is too high will lead to the problem of the seal to a certain temperature will cause deterioration of oil bearing bearing caused by excessive wear and even bite dead
Q:Pump unloading in hydraulic transmission,
Unloading is pumping oil directly back to the tank, the pressure is very low, energy saving
Q:What are the starting and stopping procedures for centrifugal pumps?
The use of centrifugal pump can be divided into three steps, namely, start, run, stop.Start: you should do the following preparation before starting:(1) check the water pump equipment in good condition.(2) the bearings are filled with oil, the oil level is normal, and the oil quality is qualified(3) all the inlet valves of the centrifugal pump are opened.(4) pump water injection or vacuum pump diversion (except for flow), open the vent valve exhaust.(5) check the leakage of shaft seal. It is advisable to fill the seal with a little drop of water.(6) the motor rotates in the right direction.
Q:Fire control center manually start the fire pump directly, multi line control, called straight up line NHKVV-7*1.5, my understanding is: straight line from fire control center
The line between the fire pump buttons should be NHBVR-4*1.5 lines. 2 start, 2 answer. Some manufacturers reported that the 3 lines can also, this need to see which is the specific equipment. In addition, we need to introduce 2 warning buses.The above lines are individually distributed
Q:How to adjust the flow of piston pump?
The oil pan with oil liquid through the suction port and the piston cylinder; from 180 degrees to 360 degrees, the piston cylinder volume decreases, so the oil liquid in the pan with oil discharged from the outlet of the liquid. The pump works continuously as long as the drive shaft rotates.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department