Product Description:

1. Product Description:

Semi-conductive nylon tape applies to the wrapping around the conductor of high voltage cross-linked polyethylene cable, oil cable and mine cable, for it has shielding and binding function. It is also non corrosive.

2. Product Characteristic:

At the same time, special solid color jacquard, heat transfer, softening treatment, can also according to customer requirements and processing all kinds of nylon webbing. High strength, is not easy to break, hygroscopicity poor, poor elasticity, dyeing performance in low temperature (60 DEG C) and can be painted, but poor light fastness, constant period according to color will and strength decreases, have to shrink, burning white smoke, odor of ammonia (dirty. It smells bad).

 

3.Specification

Property

Unit

Semi-conductive Nylon Tape

Thickness

mm

0.10±0.02

0.12±0.02

0.14±0.02

Unit weight

g/m2

90±10

100±10

110±10

Tensile strength

N/cm

≥100

≥120

≥140

Elongation at break

%

≥20

≥25

≥25

Surface resistivity

Ω

<1500

<1500

<1500

Volumn resistivity

Ω·cm

<1×106

<1×106

<1×106

Short term stability

230

230

230

Long term stability

145

145

145

 

4. Reference Picture:

 

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Fiber optic cable split box, integrated wiring box, cable terminal box, cable transfer box difference
Outdoor fire line must use fire-resistant KVV cable, wear pipe protection.
Q:What is the cable for rvv? Is it a power cable or a control cable? What is the cable?
The installation process is a certain requirement, high and low voltage cable bridge should be installed separately as usual, a wall laying vertical pipeline (slot) or installation equipment, the power distribution between the depth of D1 = 1200 ~ 1500mm; weak Between the deep distance from the D2 = 1100 ~ 1400mm more reasonable. The length L1 and L2 between the power distribution and the weak can be determined according to how much electrical equipment and pipelines (slots) are installed in the room. "Civil building electrical design specifications" proposed "shaft size in addition to meet the wiring spacing and terminal box, distribution box layout must be the size, but also in the box before the left not less than 0.8m operation, maintenance distance" requirements. In the weak equipment, the operation and maintenance distance is not specified in the provisions of the Code for Electrical Design of Civil Buildings, but it should not be less than 0.8m. Cable to wear steel pipe wiring, should be reserved in the floor steel pipe, wiring should be completed after the plug fire fire blocking material. Cable bridge installation should be horizontal, the maximum sag should not be greater than 10 mm; proposed separate installation
Q:2.5 square copper (green, with the threading tube) can withstand the highest power of several kilowatts,
Replaced with 30 * 30 PVC flameproof trough, side wiring side cover.
Q:What is the difference between wires and cables?
The introduction of the device in the form of: sealing ring (sealing ring is to achieve the required protection level of the shell and the use of cash-saving brush to help find the silent material or elastic material parts) type of introduction device; casting solidified packing seal Type introduction device; metal seal ring introduction device
Q:What kind of KVM switch is this configuration below?
Hello according to your request can be used two sets of ordinary 16 cascade, to a control terminal control 32 hosts. Is the cheapest solution. According to my understanding of the domestic Haikang series of products cost-effective, you can understand the next.
Q:How are various wire and cable models named?
Cable type a lot, here to give an example: ZRC-YJV22-0.6 / 1KV3 * 25 +2 * 16 This model specification means: C-class flame retardant (ZRC) XLPE insulated (YJ) PVC jacket 22) steel tape armor (0.6 / 1KV) 0.6 / 1 kV (3 * 25) 3 25 square (+ 1 * 16) plus two 16 square copper conductor flame retardant copper core steel tape armored cross-linked poly Ethylene insulated PVC sheathed low voltage electric power.
Q:Galvanized wire tube buried to do anti - corrosion do
Galvanized itself on the anti-corrosion, no need to do anti-corrosion treatment.
Q:A five-hole dual-socket how to connect the wiring, the electrician line to go three lines, the switch can use a single socket did not take their own hands
There are [the top of the machine can be broken off the ball can be hit by Jiu turtle snow box video output cable and DVD video output line] into a junction box, and then through the sub-box toggle switch to select the 'set-top box' or 'DVD'; This junction box outputs a wire connection device or is connected to a TV.
Q:Wire pipe inlet air switch trip how to do?
The middle of the line is not a problem where there is a problem in the place where the joints check the place of the joints can not do the lines are out to check the time and effort
Q:Is the toilet wire walk on the ground? Are there any hidden dangers?
At the same time, security monitoring line itself is a weak line

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range