Specifications

1.unshielded control cable
2.IEC BS DIM Standard
3.ISO,BCC,VDE,IQAC,CCC certification
4.Factory direct

1.U0/U :300/500V,450/750v

2.Standard: IEC60227, BS6500, VDE0250, GB/T9330 .

3.Max.working temperature:70°C, can be 90°C and 110°C as per requirement

4.Cores:2,3,4,5,7,8,10,12,14,16,19,24,27,30,37,44,48,52 and 61

5.Cross section area:0.50~10mm2  

6.Color:black or as per requirement

7.Certification:ISO9001, ISO14001,OHSMS18001,CCC,etc.

8.OEM can be available

Application:

The products are suitable for the wiring of electrical controlling equipments and instrument,monitoring and controlling return circuit,electrical protection and measurement in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.

 

The long-time working temperature of conductor of PVC insulated cable is 70°C

The long-time working temperature of conductor of XLPE insulated cable is 90oC

The temperature for laying the cables can not be lower than 0°C .Permissible bending radius(r):unarmoured cable:r≥6D;(D: outer diameter of the cable);armoured or copper-tape screened cable:r≥12D;shielded flexible cable:r≥6D

examples:

PVC insulated control cable

PVC insulated and sheathed control cable

PVC insulated and sheathed braid shield control cable

PVC insulated and sheathed Cu tape armored shield control cable

PVC insulated and sheathed aluminum tape armored shield control cable

PVC insulated and sheathed steel tape armored control cable

PVC insulated and sheathed Cu tape armored shield control steel tape armored control cable

PVC insulated and sheathed steel wire braid control cable

PVC insulated and sheathed soft control cable

PVC insulated and sheathed braid shield soft control cable

 XLPE insulated control cable

XLPE insulated PVC sheathed control cable

XLPE insulated PVC sheathed braid shield control cable

XLPE insulated PVC sheathed Cu tape armored shield control cable

XLPE insulated PVC sheathed aluminum tape armored shield control cable

XLPE insulated PVC sheathed steel tape armored control cable

XLPE insulated PVC sheathed Cu tape armored shield control steel tape armored control cable

XLPE insulated PVC sheathed steel wire braid control cable

 

Flame-retardant control cable

PVC insulated and sheathed flame-retardent A(B\C\D) control cable

PVC insulated and sheathed braid shield flame-retardent A(B\C\D)control cable

 

Fire-safe property control cable

PVC insulated and sheathed fire-safe A(B\C\D) control cable

PVC insulated and sheathed braid shield fire-safe A(B\C\D) control cable

 

Low-smoke halogenfree polyolefin control cable

XLPE/ Low-smoke halogenfree polyolefin insulated Low-smoke halogenfree polyolefin sheathed flame­-retardant A(B\C\D) control cable

XLPE/ Low-smoke halogenfree polyolefin insulated braid shield Low-smoke halogenfree polyolefin sheathed flame­-retardant A(B\C\D)control cable

Fluoroplastics insulated heat-resistance control cable

F46 insulated and sheathed heat-resistance control cable

F46 insulated and sheathed heat-resistance soft control cable

Silican rubber insulated heat-resistance control cable

Silican rubber insulated and sheathed heat-resistance control cable

Silican rubber insulated and sheathed heat-resistance soft control cable

Intrinsically safe circuit control cable

PVC insulated and sheathed intrinsically safe (soft) control cable

PVC insulated and sheathed braid shield intrinsically  safe (soft) control cable

PVC insulated and sheathed Cu tape-armored shield intrinsically  safe


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the difference between KVV and VV cables and are they clearly different?
Eight or six no less, the first good fire retardant pipe on the line, the box can be opened after the slot
Q:What is the heat of the cross-linked cable?
Video cable refers to the transmission of video signals (VIDEO) cable, can be used as a monitoring system for signal transmission
Q:Cable WDZ-YJFE2 (4X185 + 1X95) what does it mean
According to the specification requirements: 8.10 cable bridge wiring 8.10.4 cable bridge horizontal laying, should be selected according to the load curve to support the best span, span should be 1.5-3m. Vertical laying, the fixed point spacing should not be 2m. Assuming that the height of the electrical shaft is 60 m and the fixed point spacing is 2 m, then the number of stents required is: (60/2) * 2 = 60 Assuming that the height of the electrical shaft is 60 m and the fixed point spacing is 1.5 m The number is: (60 / 1.5) * 2 = 80 mainly depends on your shaft height, and the bridge fixed point spacing, hope to help you, (* ^ __ ^ *)
Q:A sub-eight splitter, behind the link ONU equipment, which also need to add fiber patch panels, or can be directly connected?
Cable and 10kV power line parallel laying the minimum distance of 0.5 meters.
Q:What is the interface between the power interface and the hard disk?
10KV generally in the bottom, 380V power cable in the middle, control cable and cable at the top
Q:Brief description of the difference between cable and cable.
Network cable is to take the digital signal, CATV cable is to take the analog signal, how can interfere with each other, do not understand do not see this stare blindly understand the beads. It was all right to be wrapped around with an electrical tape.
Q:The UV lamp is fitted with ozone and no ozone difference
. like the computer boot fast, the best way is solid state hard drive, followed by the win. the system is very good, the interface is also familiar with the boot fast, especially the new browser edge than a lot stronger; . if you now computer The monitor is also good, and now the computer's hard drive can be taken down to the new computer above, then 3000 yuan can buy very very good, desktop. If the notebook is about 4500 or so relatively high cost. . do not recommend the configuration of their own one by one to buy accessories, it is recommended that you look at the top of the machine installed Taobao business, they rely on the volume, not only to ensure that the genuine accessories, the price is relatively cheaper to buy their own, And wiring installation are also professional. And they are equipped with win7 is free to upgrade to win. very good. I just bought a few days ago a machine, monitor and hard drive or use their original, with the host with the solid-state hard drive as a boot disk, their hard drive as a storage disk, spent a total of . the performance is very good.
Q:What is the fire wire pipe laying? What is the galvanized steel pipe?
Look at the computer and television, respectively, what interface are generally computer and television are more VGA, followed by HDMI, the new out there will be DisplayPort connection at both ends of the wire type is also very rich, VGA-VGA, HDMI-HDMI, etc. also Adapter cable, such as DVI to VGA and one according to the computer and television interface to select the wire, hard link established, win7 will automatically identify, I use the flagship version, feel better than XP. You can choose to clone the screen or expand the desktop and other operations, computer monitors Internet TV while watching movies, like.
Q:How high voltage armored power cable is grounded
Insulated isolation of the double shield control cable is the outermost armor layer should be grounded at both ends, the inner shield one end of the ground, is conducive to the rapid release of induced current.
Q:Copper core power cable laying cable sets what fixed
BTS is 2G base station, a wireless network consists of N BTS and several BSC, each BTS need to access the BSC through the transmission network. 2G base station transmission interface is mostly 2M interface. SDH (Synchronous Digital System), is a technical system developed by ITU, is a transmission technology. SDH line side (that is, out of the cable) is 155M, 622M, 2.5G, 10G optical interface. Branch side (then business network equipment, including base stations) are more than 2M, FE, GE also has 155M optical interface. DDF and ODF are patch panels, DDF digital patch panels, ODF fiber patch panels. SDH line side of the ODF frame, is received on the outgoing cable, DDF frame service network equipment, in the base station is then BTS. Set the patch panel is mainly for easy maintenance, you can label on the patch panel, each interface business type is very clear. The communication system diagram in the base station is this: BTS - DDF - SDH - ODF - another bureau.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range