Round Air Swirl Diffuer For HVAC systerm Damper Vent

Ref Price:
Loading Port:
Ningbo
Payment Terms:
TT OR LC
Min Order Qty:
10 pc
Supply Capability:
500000 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specification of Air Diffuser

 

Aluminium Round Diffuser

 Supplying Air Diffusers 

-Frame Thickness: 1.0mm /0.8mm
-Any Size be customed 
-Powder Coated RAL 9010/9016

 

Usage of Air Diffuser

The grille is suitable for ceilling  sidewall, soffit or cill mounting and may be used for supply or extract applications. 

Typical installations include offices, shops, hotels and most commercial or industrial buildings.

Available as standard in white polyester powder coat finish. 

Other polyester powder  coat finishes are also available as an option.


Specification of Air Diffuser


round air diffusers

circular ceiling diffuser

round diffuser

NECK SIZE(mm)

DESCRIPTION OF GOODS

Diameter

100

1. Product name: round air diffuser

Diameter

125

2. Material: aluminum

Diameter

150

3. Powder coated: standard color, RAL 9010/9016

Diameter

160

4. Damper with

Diameter

200

5. reduce the flow resistance and noise.

Diameter

250

6. The products are easy to install and clean.

Diameter

300

7.聽 adapt to centrel air-conditioning systems.

Diameter

350

8. other size/colors available.

Dimensions,colors,thickness, finished, disigns and other specification can be customized according to customers' request



Products Show


Round Air Swirl Diffuer For HVAC systerm Damper Vent

Round Air Swirl Diffuer For HVAC systerm Damper Vent

Round Air Swirl Diffuer For HVAC systerm Damper Vent

Round Air Swirl Diffuer For HVAC systerm Damper Vent

Round Air Swirl Diffuer For HVAC systerm Damper Vent

Round Air Swirl Diffuer For HVAC systerm Damper Vent

Round Air Swirl Diffuer For HVAC systerm Damper Vent

Round Air Swirl Diffuer For HVAC systerm Damper Vent


Packing & Shipment


Packing:

PO shrink film bag for each pcs, ourter by export carton

PVC film + 4 plastic protection corners + carton box + closed wooden box optionally. 

Shipping:

within 21 days after deposit

 

Packing:

PO shrink film bag for each pcs, ourter by export carton

PVC film + 4 plastic protection corners + carton box + closed wooden box optionally. 

Shipping:

within 21 days after deposit


FAQ:

1, What's size do u have for round type diffuser?

A: We have face size from 150mm to 550mm,neck size from 250mm to 400mm

 

2, Do u still have other types ?

A: Yes, we have round diffuser/ rectangle diffuser/ linear grilles/ baseboard diffusers,etc

 

3, What's the most early delivery time?

A: Within 25 days for each 40'fcl



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What's the difference between compressor and air compressor?
Compressor: a wide range including air compressors, and others, such as oxygen, as the medium, both of which provide pressure, only the medium of compression is different
Q:What is the working principle of a two stage compressor?
The low-pressure refrigerant vapor from the evaporator (pressure P0) is advanced into the low-pressure compressor, which is compressed to the intermediate pressure PM, and then cooled into the high pressure compressor,
Q:How to analyze air conditioning parts?
Their function makes the air around the condenser and evaporator circulate, the indoor air can be circulated, and the indoor and outdoor air exchange can be realized. Electrical control system: all kinds of circuits, such as compressor circuit, temperature control circuit, protection circuit, etc., the components of these circuits and their particular components form the electrical control system of the air conditioner
Q:What about compressor overload protection?
The voltage on the compressor is too low, including the power supply voltage of the power grid is low and the contact of the power supply line is poor and the line diameter is fine. Both will cause the compressor to start the current is too large, and the protection relay action
Q:What are the system components of condensers?
Motor protector: overcurrent relay, thermal overcurrent relay, temperature relay. Temperature regulator
Q:What are the parts of an automobile air conditioner?
Refrigeration system is the use of refrigerant from the liquid into a gas, the need to absorb heat and the gas into the liquid, the principle of heat release to reduce the temperature inside the car.
Q:What are the types of condensers?
As a hot surface, the spiral fin tube has high heat exchange efficiency, sufficient heating surface, small smoke force and small side force of the flue gas system, and meets the requirements of ordinary burners
Q:What are the air compressors for?
Wind tunnel experiment, underground passage ventilation, metal smelting
Q:What are the parts of the outdoor unit?
The indoor machine comprises a heat exchange copper tube, a fan and an electric component
Q:What is the working principle of the compressor?
Compressor mainly through the motor through the refrigerant from the gas compression into liquid

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range