Rotary Heat Transfer Printing Equipment, Single Side Heating Flatbed Thermal Transfer Machine

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 Set set
Supply Capability:
100 Sets Per Month set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Packaging & Delivery

Packaging Details: wooden package
Delivery Detail: Depends on order quantity

Specifications

Rotary Heat Transfer Printing Equipment is adopted electric heating diversion around oil layer. The quality is very stable!

Rotary Heat Transfer Printing Equipment is adopted electric heating diversion around oil layer, fast temperature rising, stable temperature on cylinder surface, four shafts interlock, blanket disengaging mechanical structure, three frequency conversion adjustable device, easily operation and service, best printing effect, widely used in digital printing industry both domestic and international

Characteristics: 1) Electronic digital display temperature control temperature. 2) Aluminum hot plate used : safety, durability. 3) Electronic time control.Process is complete instructions. 4) High Temperature Materials floor installed. 5) Double spaces for high efficiency pneumatic

Features:

Double transfering plate design for saving working time

Distributing temperature evenly

Strong penetration into fabrics without print gaps

Technical Parameter:

Power Supply: 3phases,380V/50Hz or 3 phases,220V/60HZ

Power: 18KW

Work Table Size: 1.5*1.0m (59"x39")

Machine Size(cm): 230*180*140

Net Weight: 1100kg(2420lb)

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:About the elevator parts, up and down through, how this part of the heat load calculation
When the internal energy, kinetic energy and potential energy variation can be ignored and no shaft work, heat input system and should leave the system heat balance, heat balance equations for heat transfer device which can be concluded as follows: Q1, Q2 and Q3 Q4 = + Q5 + Q6 Type in Q1 - material into equipment heat, kJ. Q2 - heating agent or by the coolant to the equipment and processing materials of heat, kJ. Q3 - heat effect of the process, kJ. Q4 - material out of the equipment of heat, kJ. Q5 - heating or cooling equipment consume the amount of heat or cold, kJ. Q6 - equipment dissipating heat to the environment, kJ. Should be paid attention to in the type, in addition to Q4 and Q1, other Q values are positive and negative two cases. For example, when the reaction heat, the "+" in Q3, On the other hand, when the reaction heat, Q3 "?" , it is the opposite of the stipulation of the thermodynamics. By type (5-1) and Q2, the heat load of the equipment. If Q2 is positive, indicating that need to provide by the equipment and processing of materials with heat, namely to be heated; On the other hand, suggests that need from removing heat by the equipment and processing of materials, which need to be cooling. In addition, for intermittent operation, due to the different period of operating conditions may be different, therefore, should be according to the different period of Q2 was calculated, and take the maximum as the equipment and the design principle of the heat load. For Q2, must seek out other the caloric value of the type
Q:Thermal equipment fouling and slagging what's the harm?
After thermal equipment fouling, often caused by poor heat transfer tube wall temperature, when the temperature exceeds the metal can allow temperature, it could cause bulge and pipe explosion accidents. Water boiler water slag is too much, can affect the boiler steam quality, and perhaps blocking furnace tube, threatening the safe operation of boiler. In order to prevent fouling thermal equipment, from the following several aspects: (1) try to reduce the water hardness. (2) as far as possible to reduce silicon compounds to water, the content of aluminum and other metal oxides. (3) reduce the iron content in the water of boiler, increase the iron removal equipment. (4) reduce the copper content in water, adding complexing agent to the boiler water. (5) good feed processing, to prevent corrosion.
Q:Refrigeration equipment of the evaporator
Evaporator is also called heat absorber, which is by the boiling vaporization of liquid refrigerant load cooling or cooling heat transfer device object to be cooled. Evaporator can be divided into two kinds: one kind is the cooling liquid type, used for cooling liquid refrigerant, tube shell type evaporator and flooded evaporator (such as vertical pipe, spiral pipe, coil type). Flooded evaporator is mount the whole heat transfer surface immersed containing a cooling groove, groove Canon of stirring, strengthen heat transfer. Another kind is the cooling air, used for cooling as the agent of cold air, is divided into tube and air cooler. Tube is composed of vertical pipe and horizontal tube or coil, boiling refrigerant in the tube, pipe outside air natural convection, cooling fan is composed of pipe set of with fan, make pipe outside air forced convection.
Q:Use finned tube condenser and evaporator, its fin spacing of how to choose
Finned Tube, also called fins pipe or Finned Tube, English name is "Fin Tube" or "Finned Tube", also sometimes called the "Extended Surface Tube", namely the Extended Surface Tube. As the name implies, finned tube is on the original surface of the pipe (whether outer surface or inner surface) treatment on a lot of fin, the original surface extension, and form a unique heat transfer element.
Q:What are heat exchange equipment
Plate heat exchanger used in between two or more fluid, a kind of fluid and solid particles or between a solid and thermal contact between the same kind of fluid with different temperature of heat (or enthalpy) transfer device called a heat exchange equipment. It is the chemical industry, oil refining, food, light industry, energy, medicine, machinery and many other industries are widely used a kind of general equipment.
Q:How to wash hot water exchanger heat
A lot of heat exchanger cleaning methods 1, join in the heat exchanger cleaning liquid circulation, can take some dirt. 2, flush with water cannon directly. 3, the most radical approach is removed all clean.
Q:Heat conduction oil furnace with coal or electricity?
Electricity heat conduction oil furnace more economic and environmental protection, electric power can be adjusted by the use of heat conduction oil furnace, heating efficiency, save energy and reduce the cost, no pollution and environmental protection.
Q:How hot is spread from one end of the metal strip to the other end of the
Industry, there are many is given priority to with heat conduction heat transfer process, such as rubber products heat vulcanization, and the heat treatment of steel forgings, etc. In the kiln, heat transfer equipment and the design calculation of heat insulation and the temperature of the catalyst particle distribution analysis, the heat transfer law occupies an important position. In high temperature and high pressure equipment (such as ammonia synthesis tower and the waste heat boiler, etc.) of large-scale ethylene plant design, also need heat transfer law to calculate the equipment temperature distribution of each heat transfer within the partition for thermal stress analysis.
Q:For the same device and circulating thermal coefficient and countercurrent heat transfer coefficient is what relation?
Cold winter in the north, and the inner surface of outer wall temperature is lower than the indoor air dew point temperature, the inner surface of the outer wall condensation occurs the metope inside the trigger mold phenomenon. This kind of phenomenon will not only influence people comfortable and healthy, but also cause indoor utensils and damage of building structure.
Q:Heat conduction oil boiler equipment is normal, no pressure after running system
For you say that there are several possible, first, first check the branches have direct valve closing valve or other do not have the right to switch valve is closed or the open, resulting in heat conduction oil directly without reach equipment return oil furnace system.
As a leading manufacturer, all Microtec products are fully assembled by our state of the art manufacturing facility prior to shipment and released only after extensive testing and inspection by our qualified technicians, maintaining the strictest quality control procedures.Our mission is to be a world supplier of Heat Transfer Products and Consumables. We are committed to the principal of satisfying customer and market demands, pursing scientific administration and superior quality by using the latest technology grounded in a thorough understanding of the end-user's needs.

1. Manufacturer Overview

Location Guangdong,China
Year Established 2007
Annual Output Value
Main Markets 7.69% North America
7.69% South America
7.69% Eastern Europe
7.69% Southeast Asia
7.69% Africa
7.69% Oceania
7.69% Eastern Asia
7.69% Western Europe
7.69% Central America
7.69% Northern Europe
7.69% Southern Europe
7.69% South Asia
Company Certifications ISO 9001:2008;SGS; CE

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shenzhen,Guangzhou,Zhuhai
Export Percentage 81% - 90%
No.of Employees in Trade Department 11-20 People
Language Spoken: English, Chinese
b)Factory Information  
Factory Size: 5,000-10,000 square meters
No. of Production Lines 6
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Average