Rotary Heat Transfer Machine

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 Set set
Supply Capability:
200 Sets Per Month set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Packaging & Delivery

Packaging Details: boxes
Delivery Detail: 7-15days

Specifications

FTP-1700 rotary heat transfer machine

1.factory wholesale OEM ODM

2.High Temperature Materials floor installed.

FTP-1700 rotary heat transfer machine

Detailed Product Description

Rotary Heat Transfer Printing Equipment is adopted electric heating diversion around oil layer. The quality is very stable! Rotary Heat Transfer Printing Equipment is adopted electric heating diversion around oil layer, fast temperature rising, stable temperature on cylinder surface, four shafts interlock, blanket disengaging mechanical structure, three frequency conversion adjustable device, easily operation and service, best printing effect, widely used in digital printing industry both domestic and international

Characteristics:

1) Electronic digital display temperature control temperature.

2) Aluminum hot plate used : safety, durability.

3) Electronic time control.Process is complete instructions.

4) High Temperature Materials floor installed.

5) Double spaces for high efficiency pneumatic

Technical parameters:

Model No. FTP-1700
Printing Area 1.70 meter
Roll Diameter 37.5cm
Roll Material Oil+steel w/ 0 seam + teflon
Blanket 1.73M(Width)×2.43M(Perimeter)
Temperature Range 0-260 degree
Time Range 0-99 hour
Input voltage 380V/220V
Frequency 50-60HZ
Rating Power 14.5KW ( motor power is 0.75KW)
Input current 38A
Timing turn-off 1-12 Hours
Machine (LXWXH) 2.27×0.68×1.27M
Gross Weight 775kg

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:About the elevator parts, up and down through, how this part of the heat load calculation
Specification specified, adjacent room temperature is greater than or equal to 5 ℃, or through the partition wall and slab in heat transfer is greater than 10% of the heat load of the room, should be calculated through the partition wall or floor heat transfer, heat transfer heat consumption calculation formula to calculate the reference maintenance structure. The specification says facing correction rate, should consider the local winter relative sunshine duration, construction use and bai shade, and so on and so forth. In winter relative sunshine duration is less than 35% of the region, southeast, southwest and south to fix rate, appropriate USES - 10% ~ 0, to the east, and west is not fixed. If you describe, sunshine is obscured, are refer to the above description. Standard correction not only say, north and south, east and west four directions, suggest to scrutiny.
Q:The working principle of rotary kiln is what?
Firing equipment of cement shaft kiln, wet rotary kiln, rotary kiln and ordinary insulating dry kiln, vertical Bohr kiln and preheater kiln (SP) and the current widespread use of the new dry rotary kiln, rotary kiln. Rotary kiln, rotary kiln is a cylinder has a certain slope, slope is 3 ~ 3.5%, with the help of a kiln rotation to promote material stirring in rotary kiln, rotary kiln, the material mixing, contact each other for reaction. Kiln head pulverized coal combustion produces a large amount of heat, heat with the flame radiation, heat convection, brick kiln, kiln conduction to the material. Material depend on kiln shell Angle rotation in the kiln and kiln movement forward..
Q:The basic principle of heat exchanger is what?
The heat exchanger [is] will be part of the thermal fluid heat transfer to cold fluid equipment, also called heat exchanger. Is a kind of different temperature between two or more fluid heat transfer between the material energy saving equipment. Heat exchanger in chemical industry, petroleum, power, food and many other occupies an important place in the industrial production, its heat exchanger in chemical industry production can be used as a heater, cooler, condenser, evaporator and reboiler, etc., used widely.
Q:What are the factors affecting heat transfer rate of the chemical equipment
Cold and hot medium flow state (if) for fluid thermal conductivity, heat transfer interface
Q:When IGBT coating thermal conductive silicone, how did the general daub the ideal
The building Lord thermal conductive silicone with machine water can be erased. Times can suggest use silk screen printing, silk screen, scraper hardness 70 with 80 net cloth, Angle of 45 degrees, silk screen material with a PET or NYLON.
Q:Thermal equipment fouling and slagging what's the harm?
After thermal equipment fouling, often caused by poor heat transfer tube wall temperature, when the temperature exceeds the metal can allow temperature, it could cause bulge and pipe explosion accidents. Water boiler water slag is too much, can affect the boiler steam quality, and perhaps blocking furnace tube, threatening the safe operation of boiler.
Q:Heat conduction oil boiler equipment is normal, no pressure after running system
For you say that there are several possible, first, first check the branches have direct valve closing valve or other do not have the right to switch valve is closed or the open, resulting in heat conduction oil directly without reach equipment return oil furnace system.
Q:Use finned tube condenser and evaporator, its fin spacing of how to choose
Example 3: steam generator, the tube is the boiling water, flue gas pipe outside, fin should add in the flue gas side. When, should be paid attention to in the design, should as far as possible on the side of the heat transfer coefficient of the tube, in order to add fin. (2) such as pipe on both sides of the heat transfer coefficient is very small, in order to strengthen heat transfer, should be in both at the same time adding fin, if there is difficulties, on the structure, both sides are without fin. In this case, if only on one side and fin, the increase of heat transfer is not have obvious effect. Case 1: the traditional tubular air preheater, air tube go, flue gas pipe outside. Because is gas for gas heat exchanger, on both sides of the heat transfer coefficient is very low, the tube and fin and difficult, have to light tube. Example 2: heat pipe air preheater, although is still a flue gas heating the air, but because of the flue gas and air are outside the pipe flow, so the flue gas side and air side can be conveniently used finned tube, the heat transfer is greatly increased. (3) if the tubes on either side of the heat transfer coefficient is large, it is not necessary to adopt finned tube. Case 1: water/water heat exchanger, heat cold water with hot water, on both sides of the heat transfer coefficient is high enough, there is no need to use the finned tube. But in order to further enhance the heat transfer, can use threaded pipe or corrugated pipe instead of light. Example 2: power plant, the condenser tube is water vapor condensation, the tube water. On both sides of the heat transfer coefficient is very high, in general, without using finned tube.
Q:What is the difference between diversion in heat exchanger heat exchanger and diversion?
Diversion tube inside and outside the diversion tube flush function point of view is the same, all is in order to increase the effective heat transfer area of the heat exchanger. But from the Purpose, the latter to the former than the latter in the fixed tube plate heat exchanger can increase the amount of cloth tube heat exchanger.
Q:What are the causes of failure of plate heat exchanger?
Seal failure Plate heat exchanger leakage within the rated pressure, in addition to the equipment manufacture factors, mainly related to the system pressure and temperature of dramatic change. Impact the instantaneous pressure drop caused by the often 2 to 3 times higher than normal pressure, the installation of the rubber gasket displacement, lead to seal failure. When the temperature changes too fast, the elastic and sealing gasket pre-tightening force does not match, equipment bearing capacity is lower than the rated design pressure and leak. Precautions: 1. In the operation to avoid shock phenomenon in a system. 2. According to the condition of operating pressure increase 1.5 2.0 times the design pressure of the equipment. 3. Other measures of prestressing force compensation seal change. 4. In the operation, should try to slow warming and process of pressure
As a leading manufacturer, all Microtec products are fully assembled by our state of the art manufacturing facility prior to shipment and released only after extensive testing and inspection by our qualified technicians, maintaining the strictest quality control procedures.Our mission is to be a world supplier of Heat Transfer Products and Consumables. We are committed to the principal of satisfying customer and market demands, pursing scientific administration and superior quality by using the latest technology grounded in a thorough understanding of the end-user's needs.

1. Manufacturer Overview

Location Guangdong,China
Year Established 2007
Annual Output Value
Main Markets 7.69% North America
7.69% South America
7.69% Eastern Europe
7.69% Southeast Asia
7.69% Africa
7.69% Oceania
7.69% Eastern Asia
7.69% Western Europe
7.69% Central America
7.69% Northern Europe
7.69% Southern Europe
7.69% South Asia
Company Certifications ISO 9001:2008;SGS; CE

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shenzhen,Guangzhou,Zhuhai
Export Percentage 81% - 90%
No.of Employees in Trade Department 11-20 People
Language Spoken: English, Chinese
b)Factory Information  
Factory Size: 5,000-10,000 square meters
No. of Production Lines 6
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Average