Rotary Heat Transfer Machine

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 Set set
Supply Capability:
200 Sets Per Month set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Packaging & Delivery

Packaging Details: boxes
Delivery Detail: 7-15days

Specifications

FTP-1700 rotary heat transfer machine

1.factory wholesale OEM ODM

2.High Temperature Materials floor installed.

FTP-1700 rotary heat transfer machine

Detailed Product Description

Rotary Heat Transfer Printing Equipment is adopted electric heating diversion around oil layer. The quality is very stable! Rotary Heat Transfer Printing Equipment is adopted electric heating diversion around oil layer, fast temperature rising, stable temperature on cylinder surface, four shafts interlock, blanket disengaging mechanical structure, three frequency conversion adjustable device, easily operation and service, best printing effect, widely used in digital printing industry both domestic and international

Characteristics:

1) Electronic digital display temperature control temperature.

2) Aluminum hot plate used : safety, durability.

3) Electronic time control.Process is complete instructions.

4) High Temperature Materials floor installed.

5) Double spaces for high efficiency pneumatic

Technical parameters:

Model No. FTP-1700
Printing Area 1.70 meter
Roll Diameter 37.5cm
Roll Material Oil+steel w/ 0 seam + teflon
Blanket 1.73M(Width)×2.43M(Perimeter)
Temperature Range 0-260 degree
Time Range 0-99 hour
Input voltage 380V/220V
Frequency 50-60HZ
Rating Power 14.5KW ( motor power is 0.75KW)
Input current 38A
Timing turn-off 1-12 Hours
Machine (LXWXH) 2.27×0.68×1.27M
Gross Weight 775kg

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Why heater before operation will be into the air in the device?
The first, air expansion coefficient is big, the residual air is heated in the airtight container is in danger of explosion overpressure. Second, low thermal conductivity, air pipes in air part of can not get effective cooling during heating, may cause damage of partial wall overtemperature. Third, in line with air may form the "water hammer", a strong shock.
Q:Use finned tube condenser and evaporator, its fin spacing of how to choose
Example 3: steam generator, the tube is the boiling water, flue gas pipe outside, fin should add in the flue gas side. When, should be paid attention to in the design, should as far as possible on the side of the heat transfer coefficient of the tube, in order to add fin. (2) such as pipe on both sides of the heat transfer coefficient is very small, in order to strengthen heat transfer, should be in both at the same time adding fin, if there is difficulties, on the structure, both sides are without fin. In this case, if only on one side and fin, the increase of heat transfer is not have obvious effect. Case 1: the traditional tubular air preheater, air tube go, flue gas pipe outside. Because is gas for gas heat exchanger, on both sides of the heat transfer coefficient is very low, the tube and fin and difficult, have to light tube. Example 2: heat pipe air preheater, although is still a flue gas heating the air, but because of the flue gas and air are outside the pipe flow, so the flue gas side and air side can be conveniently used finned tube, the heat transfer is greatly increased. (3) if the tubes on either side of the heat transfer coefficient is large, it is not necessary to adopt finned tube. Case 1: water/water heat exchanger, heat cold water with hot water, on both sides of the heat transfer coefficient is high enough, there is no need to use the finned tube. But in order to further enhance the heat transfer, can use threaded pipe or corrugated pipe instead of light. Example 2: power plant, the condenser tube is water vapor condensation, the tube water. On both sides of the heat transfer coefficient is very high, in general, without using finned tube.
Q:The types of heat exchangers have?
according to heat transfer type classification 1, no phase change heat transfer Generally divided into heater and cooler. 2, with phase change heat transfer Generally divided into condenser and reboiler. Reboiler is divided into kettle reboiler, siphon reboiler, reboiler, evaporator, the steam generator and waste heat boiler.
Q:The working principle of new special viscous material scatter equipment?
Working principle is as follows: moisture content in 25 to 40% of the wet material has reunited sex or agglomerate material is entered into the scattered conveying cavity, the high-speed rotation of the rotor was carried out on the material impact, shear, make the material crushing reduction.
Q:Heat conduction oil furnace with coal or electricity?
Electric power can be adjusted by the use of heat conduction oil furnace, heat efficiency, save energy, reduce the cost, no pollution and environmental protection.
Q:What is the difference between diversion in heat exchanger heat exchanger and diversion?
In diversion tube heat exchanger is inside the shell side of heat exchanger tube set up within the guide tube make the before or after the end of the heat exchanger without diverting tube before use hard to make full use of the heat transfer of heat exchange tube, thereby increasing the effective heat transfer area of heat exchanger. The diversion tube used In the floating head or fixed tube plate heat exchanger, and less common in the u-tube heat exchanger.
Q:Why do you say modern cooking heating equipment is a combination of three kinds of heat transfer?
Modern cooking heating equipment, hot liquid (fire) (containers) bottom heating pan, pan gravy accept the pot from the surface of the hot water, this is the convection heat transfer;
Q:For the same device and circulating thermal coefficient and countercurrent heat transfer coefficient is what relation?
Little effects on downstream flow heat exchange coefficient. It should be said that both close. With the influence of heat transfer coefficient with fluid flow velocity, fluid property (related to import and export temperature), the structure of the equipment. The same device, a heat transfer coefficient of downstream and upstream won't, but the gap is not big. The same device, so the heat exchange area of the same; Upstream downstream, logarithmic mean temperature difference is different Assumes that the heat transfer coefficient is consistent, fluid temperature of import and export have change Inlet temperature and temperature changes, fluid physical properties are changed, the physical properties changed little Fluid physical properties are changed, heat transfer coefficient is also have change So the heat transfer coefficient, but the impact is not big.
Q:Heat conduction oil boiler equipment is normal, no pressure after running system
For you say that there are several possible, first, first check the branches have direct valve closing valve or other do not have the right to switch valve is closed or the open, resulting in heat conduction oil directly without reach equipment return oil furnace system.
Q:What are the causes of failure of plate heat exchanger?
Scale will lower the heat transfer coefficient of plate heat exchanger, serious blocking plate channel. Plate heat exchanger plate design of contact with a lot of support, is easy to gather solid impurities or fibers, easy to make the fluid to form local retention and scaling. Ca2 +, in addition, the medium magnesium 2 + can precipitate solid form scale, fouling and plugging formation is different, but the impact is the same. Precautions: 1, the plate heat exchanger should not be used in a dirty or easy scaling of the environment. 2, made of not soften water medium, operating temperature should be controlled under 50 ℃.
As a leading manufacturer, all Microtec products are fully assembled by our state of the art manufacturing facility prior to shipment and released only after extensive testing and inspection by our qualified technicians, maintaining the strictest quality control procedures.Our mission is to be a world supplier of Heat Transfer Products and Consumables. We are committed to the principal of satisfying customer and market demands, pursing scientific administration and superior quality by using the latest technology grounded in a thorough understanding of the end-user's needs.

1. Manufacturer Overview

Location Guangdong,China
Year Established 2007
Annual Output Value
Main Markets 7.69% North America
7.69% South America
7.69% Eastern Europe
7.69% Southeast Asia
7.69% Africa
7.69% Oceania
7.69% Eastern Asia
7.69% Western Europe
7.69% Central America
7.69% Northern Europe
7.69% Southern Europe
7.69% South Asia
Company Certifications ISO 9001:2008;SGS; CE

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shenzhen,Guangzhou,Zhuhai
Export Percentage 81% - 90%
No.of Employees in Trade Department 11-20 People
Language Spoken: English, Chinese
b)Factory Information  
Factory Size: 5,000-10,000 square meters
No. of Production Lines 6
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Average