1.Applications

PVC insulated nylon sheathed wire is according to UL62, UL83, UL1581 standard and the design and manufacture. Nylon sheathed line main model have: THHN, THWN, 80 ℃ and 105 ℃ and heat resistance level.

Nylon sheathed wire is more excellent electrical and physical properties, good heat resistance, can slow or reduce the PVC components has escaped or migration. Nylon sheathed line with protection against corrosion and self lubrication and oil resistance characteristics, and the same specification PVC insulated wire with diameter than it small, light weight, small static friction coefficient and anti-corrosion, can improve the safety in laying and suitability.


AWG

Conductors Construction

n/mm

Conductor

Outer diameter

mm

PVC Insulation

Min Average Thickness mm

 

PVC Insulation

Reference outer diameter

mm

Nylon-jacketMin Average Thickness mm

Wire reference

Outer diameter

mm

Maximum DC resistance at 20 ℃Ω/km

22

1/0.643

0.64

0.38

1.46

0.10

1.66

54.3

22

7/0.254

0.76

0.38

1.58

0.10

1.78

54.3

22

11/0.200

0.77

0.38

1.59

0.10

1.79

54.3

22

17/0.160

0.76

0.38

1.58

0.10

1.78

54.3

21

1/0.724

0.72

0.38

1.54

0.10

1.74

42.7

21

17/0.178

0.85

0.38

1.67

0.10

1.87

42.7

21

21/0.160

0.85

0.38

1.67

0.10

1.87

42.7

20

1/0.813

0.81

0.38

1.63

0.10

1.83

33.9

20

7/0.310

0.93

0.38

1.75

0.10

1.95

33.9

20

21/0.180

0.95

0.38

1.77

0.10

1.97

33.9

20

26/0.160

0.94

0.38

1.76

0.10

1.96

33.9

18

1/1.020

1.02

0.38

1.84

0.10

2.04

21.4

18

7/0.390

1.17

0.38

1.99

0.10

2.19

21.4

18

16/0.254

1.17

0.38

1.99

0.10

2.19

21.4

18

34/0.180

1.21

0.38

2.03

0.10

2.23

21.4

18

41/0.160

1.18

0.38

2.00

0.10

2.20

21.4

16

1/1.300

1.30

0.38

2.12

0.10

2.32

13.5

16

7/0.500

1.50

0.38

2.32

0.10

2.52

13.5

16

19/0.300

1.50

0.38

2.32

0.10

2.52

13.5

16

26/0.254

1.49

0.38

2.31

0.10

2.51

13.5

16

65/0.160

1.49

0.38

2.31

0.10

2.51

13.5

14

1/1.630

1.63

0.38

2.45

0.10

2.65

8.45

14

7/0.620

1.86

0.38

2.68

0.10

2.88

8.45

14

19/0.373

1.87

0.38

2.69

0.10

2.89

8.45

14

41/0.254

1.88

0.38

2.70

0.10

2.90

8.45

14

105/0.160

2.15

0.38

2.97

0.10

3.17

8.45

12

1/2.060

2.06

0.38

2.88

0.10

3.08

5.31

12

7/0.810

2.43

0.38

3.25

0.10

3.45

5.31

12

19/0.480

2.40

0.38

3.22

0.10

3.42

5.31

12

65/0.254

2.36

0.38

3.18

0.10

3.38

5.31

10

1/2.588

2.59

0.51

3.69

0.13

3.95

3.36

10

7/0.980

2.94

0.51

4.04

0.13

4.30

3.36

10

19/0.595

2.98

0.51

4.08

0.13

4.34

3.36

10

49/0.370

2.99

0.51

4.09

0.13

4.35

3.36

10

105/0.254

3.41

0.51

4.51

0.13

4.77

3.36

8

1/3.270

3.27

0.76

4.85

0.13

5.11

2.11

8

7/1.250

3.75

0.76

5.33

0.13

5.59

2.11

8

19/0.750

3.75

0.76

5.33

0.13

5.59

2.11

8

78/0.370

4.28

0.76

5.86

0.13

6.12

2.11

8

168/0.254

4.31

0.76

5.89

0.13

6.15

2.11

6

7/1.630

4.89

0.76

6.47

0.13

6.73

1.33

6

19/0.950

4.75

0.76

6.33

0.13

6.59

1.33

6

66/0.511

5.43

0.76

7.01

0.13

7.27

1.33

6

105/0.404

5.42

0.76

7.00

0.13

7.26

1.33

6

126/0.370

5.43

0.76

7.01

0.13

7.27

1.33

6

266/0.254

5.48

0.76

7.06

0.13

7.32

1.33

4

7/1.961

5.88

1.02

8.02

0.13

8.28

0.84

4

19/1.200

6.00

1.02

8.14

0.13

8.40

0.84

4

105/0.511

6.85

1.02

8.99

0.13

9.25

0.84

4

168/0.404

6.85

1.02

8.99

0.13

9.25

0.84

4

420/0.254

6.81

1.02

8.95

0.13

9.21

0.84

2

7/2.473

7.42

1.02

9.56

0.13

9.82

0.53

2

19/1.510

7.55

1.02

9.69

0.13

9.95

0.53

2

266/0.404

8.62

1.02

10.76

0.13

11.02

0.53

2

312/0.370

8.55

1.02

10.69

0.13

10.95

0.53

2

672/0.254

8.62

1.02

10.76

0.13

11.02

0.53

1

7/2.780

8.34

1.27

10.98

0.18

11.34

0.42

1

19/1.690

8.45

1.27

11.09

0.18

11.45

0.42

1

209/0.511

9.67

1.27

12.31

0.18

12.67

0.42

1

340/0.400

9.52

1.27

12.16

0.18

12.52

0.42

1

396/0.370

9.06

1.27

11.70

0.18

12.06

0.42

1

840/0.254

9.50

1.27

12.14

0.18

12.50

0.42

1/0

191.900/

9.50

1.27

12.14

0.18

12.50

0.33

1/0

266/0.511

10.28

1.27

12.92

0.18

13.28

0.33

1/0

418/0.404

10.93

1.27

13.57

0.18

13.93

0.33

1/0

498/0.370

10.93

1.27

13.57

0.18

13.93

0.33

1/0

1056/0.254

9.45

1.27

12.09

0.18

12.45

0.33

2/0

19/2.130

10.65

1.27

13.29

0.18

13.65

0.26

2/0

329/0.511

12.27

1.27

14.91

0.18

15.27

0.26

2/0

532/0.404

12.33

1.27

14.97

0.18

15.33

0.26

2/0

630/0.370

12.29

1.27

14.93

0.18

15.29

0.26

2/0

1330/0.254

12.26

1.27

14.90

0.18

15.26

0.26

3/0

19/2.390

11.95

1.27

14.59

0.18

14.95

0.21

3/0

418/0.511

13.83

1.27

16.47

0.18

16.83

0.21

3/0

666/0.404

13.80

1.27

16.44

0.18

16.80

0.21

3/0

795/0.370

13.81

1.27

16.45

0.18

16.81

0.21

4/0

19/2.680

13.40

1.27

16.04

0.18

16.40

0.17

4/0

513/0.520

15.59

1.27

18.23

0.18

18.59

0.17

4/0

840/0.404

15.50

1.27

18.14

0.18

18.50

0.17

4/0

999/0.370

15.48

1.27

18.12

0.18

18.48

0.17


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:HELP PS3 POWER CABLE !!!!?
If you guys in Italy use the one that is a right side up version is this =D then you should be fine. If bot you can buy a replacement cable for like $20 at a game store or best but or something like that.
Q:Why do phone lines stay on when other lines power and cable will go out during a storm?
I'm just amazed at how little people know about everyday things. The phone company actually runs their phones on BATTERIES... so when the power goes out, the batteries keep the phones alive... it has been done this way for OVER 100 YEARS... so it's nothing new.
Q:Double sided AC power cable pins?
The hot side of outlets has a smaller socket dimension, and that's supposed to prevent a plug that has an assigned neutral from being plugged in with the neutral (wider blade) side connected to the hot side. If your plug has two of the wider blades, then that does sound like a manufacturing defect. I'd complain to the manufacturer or vendor. Hopefully the power cord is removable, so you don't have to return the whole unit.
Q:UPS to Laptop Power Conversion Cable?
you can use a plug point from the ups and then from it you can connect it with the lap.. but, i dono why you need ups for your laptop!!!!!
Q:is 400V submarine power cable available?
You probably need a higher voltage than that, depending on the distance. That is 1500 amps which needs a hugh cable. This should be stepped up to a much higher voltage. And yes, cables are available. If you don't know that, then you need to hire a qualified electrician to do this. edit, sorry, 150 amps, less if this is 3 phase. But still a lot of current. AND the wire size will depend on the distance. More than a few hundred feet and the size has to go up to keep the voltage drop below 5% .
Q:Where can I find a 4 Pin Fan Power Splitter Cable in hamilton Ontario?
Before hooking that up, check the specs on your motherboard to see if that fan header will support loads from both fans. You may need to get a Molex to 4-pin converter and power directly off your power supply.
Q:does my power supply need to have 2 pci e connectors for my graphics card to work?
The adapter must have two of the four pin Molex connectors. It uses three of the wires, in the four pin Molex connector. (3 wires x 2=One 6 pin PCI-Express power connector)
Q:I lost my power cable for my Ipod Shuffle 2nd Gen, can I use the 3rd gen shuffle power cord for the 2nd gen?
look and see if the adaptor will fit...if so it should...i doubt they will though
Q:Formula of current carrying capacity of electrical power cables?
There is no definite safe formulas for your cables because it depends on many factors like what conductor . what insulation, how many cores ,what is your load , where is your load and ambient temperature and so on. The best guidance will be from the particular manufacturer who would provide the tables under various conditions as above.
Q:How long is the service life of the cable?
cable bridge and other pipes and other facilities shall not share a column (bracket)

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range