Rack Tower UPS HP9115CRT 1-10KVA

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
100 Units pc
Supply Capability:
4500 Pieces per Month pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Key Features:

 

Rack & Tower Design UPS

 

0.8 Output Power factor

 

LCD Display

 

Intelligent slot available

 

pure high frequency online UPS,with voltage adjustment circuit, provide stable power protection in bad operation environment

 

comprehensive electrical isolation protection and bypass protection, self test function

 

Input neutral and live wire detection function and data protection function

 

Main power failure,going to DC staring ,Convenient and reliable; Main power recover,UPS start automatically

 

 

Model

HP9115CRT  1-10KVA

HP9315CTR  10KVA

1KR/1KR-XL

2KR/2KR-XL

3KR/3KR-XL

6KR/6KR-XL

10KR/10KR-XL

10KR/10KR-XL

Capacity

1KVA/800W

2KVA/1600W

3KVA/2400W

6KVA/4800W

10KVA/8000W

10KVA/8000W

Nominal Voltage

220/230/240VAC

380VAC

Frequency

50/60 Hz

Input

VoltageRange

115~295VAC(±3VAC)

176~297VAC(±3VAC)

304~478VAC(±3VAC)

FrequencyRange

50HZ:(46~54HZ);60HZ:(56HZ~64HZ)

Power Factor

>0.98

Output

Voltage precision

220/230/240X (1±2%)VAC

Frequency precision

50/60HZ±0.05Hz

Power Factor

0.8(option)

Harmonic Distortion

Linear Load<3%    Non-Linear Load<6%

Overload capacity

overload(110%~150%)after 30 seconds automatically transfer to bypass, it recover after  normal load

Current Crest Ratio

3:1

Transfer time

0ms(AC→DC)

Battery

DC voltage

36VDC

72VDC                                       96VDC

192VDC &240VDC optional

Recharge time

5 hours to 90%

Charge Current

1A

4A/8A  optional

1A

4A/8A optional

1A

4A/8A optional

2.0A/4.2A(option)

Panel Display

LCD

Display input and output voltage, frequency, battery voltage, battery capacity, and the percentage of load

Communicate

Communicate  interface

RS232, SNMP card(option, USB port(option)

Working Environment

Temperature

0~40°C

Humidity

0~95% non-condensing

Storage Temperature

-25°C~55°C

Elevation

<1500 meter

Noise Level(1meter )

<45dB

<50dB

Physics Characteristic

Weight(KG)

N.W

16.5

9

26

11.5

26

12.5

18.5

18.5

25

32

25

32

G.W.

18.5

11.5

28

14.5

28

15

21.5

21.5

28.2

35

28.2

35

Dimension (WXDXH)

447x450 x130

447x600x130

447x450x130

447x600x130

447x450x130

447 x600x130

447x600x177

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
If there is no painting can be used with a diode symbol file (measuring probe connected to the capacitor to hear a sound if the table does not ring at the table and then the general display is 1, then the pen on the emergence of the phenomenon that the capacitance is still good. If one table has been ringing that received the capacitor capacitor breakdown is broken)
Q:What type of low voltage transformer should be adopted for safety lighting power supply?
Isolated transformer, once 380V or 220V, two voltage, 36V, 24V, 12V, several categories, do not allow the use of autotransformer.
Q:Why should lighting transformers be used in factories and mines?
But in many cases, such as mines and machinery, the voltage is too high and unsafe. The lighting transformer is then used to reduce the voltage to the so-called "safety voltage""
Q:Why is elevator lighting transformer installed?
9.4.5 well distribution shall comply with the following requirements:1 the elevator hoistway shall be dedicated to the elevator, and no equipment, cables and other devices related to the lift shall be installed in the hoistway.2 the well shall be provided with illumination, and the illumination shall not be less than 501x, and shall comply with the following requirements:
Q:1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
First of all, make sure your power is too large, but you are not recommended to do so, the cost is too high, the pressure drop is too large, you can raise the voltage to 220V or higher, and then transfer to avoid power losses. If the direct transmission, the power is slightly larger, the line will be very rough, the cost will be very high
Q:Is the substation separate from the power and illumination transformer?
The power and illumination of the substation are all used on a transformer, which is separated by power and lighting by the station screen of this transformer.
Q:How is the lighting power of the 380V transformer calculated?
With a light bulb with 4KVA load, the premise of the distance can be Mrs. face light bulb, dark can light the best load, 3KVA bulb brightness
Q:Lighting, lights, transformers, bulb brightness is too low, what's the matter?
Line light for safety light, voltage 24 volts and 36 volts, pay attention to the bulb and transformer voltage matching.
Q:Who knows how big transformers and lines the 36V transformer uses in lighting?
Depending on your load capacity, primary voltage, site reservation, etc.. For example, 3.6KW lighting, with 4KVA transformers, the primary side 380V with 2.5 square (copper wire) enough, two times the side of 25 square.
Q:Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
The previous elevator hoistway lighting required the 36V safety voltage, and you can see how many power lamps are required for the hoistway, and select the transformer
We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications.if you have interesting, please kindly contact us! We will provide our good quality products and best services to you!

1. Manufacturer Overview

Location Guangdong,China (Mainland)
Year Established 2006
Annual Output Value US$10 Million - US$50 Million
Main Markets 9.09% North America
9.09% South America
9.09% Eastern Europe
9.09% Southeast Asia
9.09% Africa
9.09% Mid East
9.09% Eastern Asia
9.09% Western Europe
9.09% Southern Europe
9.09% South Asia
Company Certifications UPS CE UG/UX 1K; UPS CE (UG/UX) 2/3K; standards organisation of nigeria soncap; Soncap UX6K

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shenzhen China
Export Percentage 61% - 70%
No.of Employees in Trade Department 11-20 People
Language Spoken: English, Chinese
b)Factory Information  
Factory Size: 10,000-30,000 square meters
No. of Production Lines 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Low and/or Average