Rack Tower UPS HP9115CRT 1-10KVA

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
100 Units pc
Supply Capability:
4500 Pieces per Month pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Key Features:

 

Rack & Tower Design UPS

 

0.8 Output Power factor

 

LCD Display

 

Intelligent slot available

 

pure high frequency online UPS,with voltage adjustment circuit, provide stable power protection in bad operation environment

 

comprehensive electrical isolation protection and bypass protection, self test function

 

Input neutral and live wire detection function and data protection function

 

Main power failure,going to DC staring ,Convenient and reliable; Main power recover,UPS start automatically

 

 

Model

HP9115CRT  1-10KVA

HP9315CTR  10KVA

1KR/1KR-XL

2KR/2KR-XL

3KR/3KR-XL

6KR/6KR-XL

10KR/10KR-XL

10KR/10KR-XL

Capacity

1KVA/800W

2KVA/1600W

3KVA/2400W

6KVA/4800W

10KVA/8000W

10KVA/8000W

Nominal Voltage

220/230/240VAC

380VAC

Frequency

50/60 Hz

Input

VoltageRange

115~295VAC(±3VAC)

176~297VAC(±3VAC)

304~478VAC(±3VAC)

FrequencyRange

50HZ:(46~54HZ);60HZ:(56HZ~64HZ)

Power Factor

>0.98

Output

Voltage precision

220/230/240X (1±2%)VAC

Frequency precision

50/60HZ±0.05Hz

Power Factor

0.8(option)

Harmonic Distortion

Linear Load<3%    Non-Linear Load<6%

Overload capacity

overload(110%~150%)after 30 seconds automatically transfer to bypass, it recover after  normal load

Current Crest Ratio

3:1

Transfer time

0ms(AC→DC)

Battery

DC voltage

36VDC

72VDC                                       96VDC

192VDC &240VDC optional

Recharge time

5 hours to 90%

Charge Current

1A

4A/8A  optional

1A

4A/8A optional

1A

4A/8A optional

2.0A/4.2A(option)

Panel Display

LCD

Display input and output voltage, frequency, battery voltage, battery capacity, and the percentage of load

Communicate

Communicate  interface

RS232, SNMP card(option, USB port(option)

Working Environment

Temperature

0~40°C

Humidity

0~95% non-condensing

Storage Temperature

-25°C~55°C

Elevation

<1500 meter

Noise Level(1meter )

<45dB

<50dB

Physics Characteristic

Weight(KG)

N.W

16.5

9

26

11.5

26

12.5

18.5

18.5

25

32

25

32

G.W.

18.5

11.5

28

14.5

28

15

21.5

21.5

28.2

35

28.2

35

Dimension (WXDXH)

447x450 x130

447x600x130

447x450x130

447x600x130

447x450x130

447 x600x130

447x600x177

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
If there is no painting can be used with a diode symbol file (measuring probe connected to the capacitor to hear a sound if the table does not ring at the table and then the general display is 1, then the pen on the emergence of the phenomenon that the capacitance is still good. If one table has been ringing that received the capacitor capacitor breakdown is broken)
Q:Why should lighting transformers be used in factories and mines?
There are two cases. One is the general factories and mines, and the low voltage is three-phase four wire system, and the neutral point is directly grounded. Between the phase line and the zero line is 220V, which can be connected with the illumination load.
Q:1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
To 30VA/ square meters, the transformer needs 30KVA, with two 120 square copper wire. Specific should be used to determine the total power of the lighting transformer.
Q:Is the substation separate from the power and illumination transformer?
The power and lighting power supply in the substation need not be separated. In a large capacity power plant, the lighting can be electrically powered to ensure that the generator is stopped. The lighting source is often separated from the lighting transformer and powered by other power supplies.
Q:The transformer zero line has broken, has the result to the household illumination circuit?
The zero line is connected to the transformer neutral point of transformer, three FireWire for its voltage is 220 volts, according to regulations, the total can not take the zero line fuse, switch, because once the zero line is disconnected, the rest of the line will no longer be a neutral line, into the use of electrical appliances connected to two the conductor, according to the characteristics of series circuit, each phase with electrical voltage, on load distribution, change the original load smaller which phase by using electrical appliances, will damage due to excessive voltage.
Q:How many power illuminator can 5Kva 36V transformer drive?
Transformer (Transformer) is a device that uses the principle of electromagnetic induction to change AC voltage. The main components are primary coil, secondary coil and iron core (magnetic core). The main functions are voltage conversion, current conversion, impedance transformation, isolation, voltage stabilization (magnetic saturation transformer) and so on. According to use can be divided into: power transformers and special transformers (electric furnace transformer, rectifier transformer, power frequency test transformer, voltage regulator, mine, variable audio transformers, intermediate frequency transformers, high frequency transformer, transformer, instrument transformer, the impact of electronic transformer, reactor, transformer etc.). Circuit symbols are often used as the beginning of numbers. Examples: T01, T201, T, etc..
Q:How many 40W bulbs can be brought into the 1000VA lighting transformer?
Voltage x current = power, in general we are using the total power of 2/3, you can press this type of calculation, if the installation of electrodeless lights, the line should be separated,
Q:Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
General line lights are 36 volts, especially in the damp and harsh environment, the light transformer adopts 24 volts voltage;After the use of light transformers, can generally live operations, first, low voltage, less dangerous, and the two is a transformer isolation, safety is greater, so you can live work, generally there will be no electric shock accident. (as long as the power is not in the hands and hands, the two end of the power supply, there will be no electric shock.)
Q:Why can't autotransformer be used as transformer for safety lighting?
The main and auxiliary coils of the autotransformer have common parts. Once the short-circuit is made, the lighting circuit is directly connected with the high voltage circuit, which is very dangerous
Q:Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
Because of the brightness of the 36V safety voltage lamp brightness in the overhaul work is not enough, so now the well lighting design should not be 36V, and replaced by 220V, and only need to add a leakage protector on it.
We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications.if you have interesting, please kindly contact us! We will provide our good quality products and best services to you!

1. Manufacturer Overview

Location Guangdong,China (Mainland)
Year Established 2006
Annual Output Value US$10 Million - US$50 Million
Main Markets 9.09% North America
9.09% South America
9.09% Eastern Europe
9.09% Southeast Asia
9.09% Africa
9.09% Mid East
9.09% Eastern Asia
9.09% Western Europe
9.09% Southern Europe
9.09% South Asia
Company Certifications UPS CE UG/UX 1K; UPS CE (UG/UX) 2/3K; standards organisation of nigeria soncap; Soncap UX6K

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shenzhen China
Export Percentage 61% - 70%
No.of Employees in Trade Department 11-20 People
Language Spoken: English, Chinese
b)Factory Information  
Factory Size: 10,000-30,000 square meters
No. of Production Lines 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Low and/or Average