 QZ Submersible Axial Flow Pump China Water Pumps


1) Features:                A) Vertical structure
                                                   B) Fitted with vertical motor
                                                   C) Long shaft
                                                   D) High efficiency

                                                                    E) Good vapor erosion resistance



2) Applications:
                                                                     A) Hydraulic projects
                                                     B) Farm-land irrigation
                                                     C) Industrial water transportation
                                                     D) Water supply and drainage
                                                     E) Water allocation engineering



3) Technical data:
                                                      A) Flow: 83 - 48, 888m3/h
                                                      B) Head: 1 - 30.6m
                                                     C) Medium temperature: 50oC
                                                     D) Operation pressure: 2.5Mpa
                                                     E) Diameter: 350 - 1, 800mm
                                                     F) Power: 4 - 20, 00kW
                                                    G) Voltage: 355kW, 6kV, 10kV

 

4)Material Standard:

                                                                   A)Casing: cast iron 

                                                                   B)Impeller:cast iron/ Carbon steel/stainless steel

                                                                  C)Shaft: Carbon/Cr-steel

5)Pictures


QZ Submersible Axial Flow Pump China Water Pumps




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What does "ETA" mean in the selection of pumps?
NPSH refers to the cavitation, the pump is the technical parameters
Q:Can centrifugal pumps be idle? What's the status of the empty transfers?
It burns and seals when idling. The individual thinks that it can be indirectly reacted according to the pressure change in the pipeline, and the electric contact pressure gauge can be installed on the suction pipe
Q:Pump suction and pressure side road why should vacuum table and pressure gauge, and what role they have?
The vacuum meter is used to measure the vacuum degree of the water pump before the water pump pumping, and to a certain degree of vacuum, the water can be sucked into the upward pressure position of the pump.A pressure gauge is used to indicate that the pumping is pressure in the pipe. The size of the pressure is related to the lift head, pipe diameter, atmospheric pressure and so on.
Q:1.5 kW three-phase pump with 600 meters line, should match what big line?
Resistivity of copper conductors is 0.017 ohm mm / m, R= P L/S, the resistance can be obtained by 600 meters 2.5 mm - single stranded conductor is 4.08 ohms, and rated current 1.5KW three-phase pump is about 3A, so the pressure drop resistance of the wire leading to the U=4.08X3=12.24V. So if the supply voltage can be stabilized at 380V~400V, with 2.5 mm - cable; if the supply voltage is between 370~390V, with 4 mm - cable. (above is copper core, aluminum core shall be increased by 1)
Q:Power flow conversion of water pump
Pump shaft power (kw) = water supply (L / s) x lift (m) /102 * efficiency = flow * lift * density * acceleration of gravity.Explanation:102 is the unit collation constant.Pump effective power / pump shaft power = pump efficiency (general 50%--90%, large pump higher)Unit time pump liquid volume flow is, flow by Q, a unit of measure: m3 / h (m3/h), L / S (l/s), L/s=3.6 m3/h=0.06 m3/min=60L/minG=Q G refers to weight - liquid proportionThe energy obtained by pumping a liquid of a unit weight is called a lift. The pump head, including suction stroke, is approximately the difference between the pump outlet and inlet pressure. The lift is expressed in H, and the unit is m.The efficiency of a pump is the ratio of the effective power to the axial power of the pump. ETA =Pe/P pump power usually refers to the input power, the motive power to the pump shaft, it is also called the shaft power, denoted by P. Effective power is the product of pump head and mass flow and gravity acceleration
Q:Why does the water pump in the tank pull out the power supply and then plug it in?
After the water pump of the fish tank pulls out the power supply, it is plugged in again. The possible reasons for the non pumping of water are as follows:1, power failure, please check the power supply contact is normal.2, continuous cycle interrupt, this is the pump design reasons, and more appear in the waterfall filter, once the electricity can not automatically restart, need to pump the water in the artificial vessel.3, air embolism, this is the pump design reasons, and more appear in the waterfall bucket filter, once the electricity can not automatically restart, the need for manual pressing to exhaust.4, the water pump is stuck with debris, in the continuous flow of water, debris to the same direction, once the pump stop, debris position change may be stuck water pump, remove, wash it.5, severe wear, which requires a new pump.
Q:4--6 inch deep well pump head? How much per hour out of water?.
Best answerLift pump is the location of the outlet is high, such as wells 5 meters deep, you put the pumping pipe on the bottom, the pump is placed in the vicinity of well, then, the head is 5 meters, the water power how much you buy depends on the pump, the greater the power, the faster the water pumping. The greater the party...
Q:How to introduce water pump?
First, to explain the basic parameters, such as pump flow, head, motor power, efficiency, outlet diameter, single-stage pump or multi-stage pump, fixed pump or submersible pump, water pump or sewage pump, deep well pump, self suction pump etc..
Q:90kw pump star delta start, in the end to use the circuit breaker, AC contactor (Star contactor, angle contactor), what kind of thermal relay?
Imports, such as Schneider, press: plastic case press 250A, contactor select 115 of 2, 95 of 1 can.Domestic recommendations: Press: plastic case press 250A, contactor 160, 2, 115 of the 1 can.
Q:How many lift pumps should be used for 100 meters tall buildings?
35m lift around. HVAC pump lift is generally between 5~50m, the selection of the head is mainly to see the difference between water pressure. As head of 35m as an example, if the inlet height of 60m, so the theory of height =60+35=95m, if all pipe closed air conditioning water system, and resistance of the equipment for water is equal to the pressure difference is equal to the pump head to choose your height, and out of the water is the same, the resistance loss of lift all into the water. The calculated resistance loss is needed to pump lift. The resistance component (1) chiller resistance at 60-100kpa (2) water collector resistance in 120-200kpa (3) 20-50kpa (4) air terminal equipment body resistance is generally not less than 40kpa so 100m building the resistance calculation of estimated value = (1) 80kp+ (2) chiller resistance pipe, the collector resistance (140kpa+ 3) air terminal equipment 40kpa+ (4) body resistance 50kp=310kpa safety factor of 10% 320x1.1=341kpa H= P/ (head of pressure water density * acceleration of gravity g =352000/ (10m) X9.8 =34.8m fand) so we head for 35 meters

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range